15 June 2023 in Biomedical Signal Processing and Control
ABAnzhelika V. Belaventseva
Anzhelika V. Belaventseva
+2
15 November 2024 in Biomedical Signal Processing and Control
ASAnastasiia V. Sakovskaia
1 February 2023 in Scientific and Technical Journal of Information Technologies, Mechanics and Optics
The possibility of using a new contactless method of imaging photoplethysmography to assess thermoregulatory vasodilatation of blood vessels was studied. Perfusion reaction in a region of the outer forearm in response to local heating up to 41 ± 1 °C was monitored in six volunteers aged 39–52 years using a video recording of the study area, synchronized with an electrocardiogram, and subsequent correlation processing of the data obtained. It was shown that the change in perfusion during local heating has a biphasic type and is due to the response of the nervous system mediated by the axon reflex in the first phase of vasodilation and the synthesis of nitric oxide in endothelial cells in the second phase of vasodilation. It was revealed that the multiple increase in perfusion in the first phase of heating depends both on the initial temperature of the skin and on the difference in its heating temperature. It was found that for a significant development of a vascular response to hyperthermia associated with the activation of endothelial function, heating of tissues for more than 15 minutes is necessary. It was shown that the method of imaging photoplethysmography reliably reflects the work of the mechanisms of regulation of peripheral vascular resistance which is of great prognostic value for the detection of primary signs of cardiovascular diseases.
1 December 2023 in Bulletin of the Lebedev Physics Institute
This work demonstrates for the first time a possibility of assessing changes in the parameters of cortical blood flow in mice through the intact cranial bo
15 October 2026 in SSRN Electronic Journal
Imaging photoplethysmography (iPPG) holds promise for contactless quantification of changes in tissue perfusion during surgery, including minimally invasive laparoscopic interventions. Unfortunately, its intraoperative use is limited by the strong influence of motion artifacts, enhanced by specular reflections from glare, which are usually suppressed by polarization filtering using crossed linear polarizers. However, this type of filtering is unlikely to be realized in the case of a laparoscope or endoscope due to their small aperture. This study suggests an easier-to-implement filtering solution using circularly polarized light (CPL). Unlike the filtering with a pair of crossed linear polarizers, the CPL filter consists of a single optical element that does not require any adjustment to suppress specularly reflected light. In this article, we report the results of an experimental comparison of iPPG waveforms obtained from a deliberately moistened region of subject’s forearm (to simulate intraoperative conditions) when illuminated with (i) nonpolarized, (ii) linearly polarized, and (iii) circularly polarized light. Our study has revealed that each type of the polarization filtering significantly improves the repeatability of the shape of the observed pulse wave in both space and time compared to measurements in unpolarized light. We hypothesize that this improvement is due to suppression of motion artifacts associated with the ballistocardiographic effect. It was shown that the CPL filter is as effective at suppressing glare as the crossed linear polarizers, highlighting its potential for integration into the laparoscope.