Background: The Rey-Osterrieth Complex Figure Test (RCFT) is a neuropsychological test that is widely used to assess visual memory and visuoconstructional deficits in patients with cognitive impairment, including Alzheimer disease (AD). Patients with AD have an increased tendency for exhibiting extraordinary behaviors in the RCFT for selecting the drawing area, organizing the figure, and deciding the order of images, among other activities. However, the conventional scoring system based on pen and paper has a limited ability to reflect these detailed behaviors. Objective: This study aims to establish a scoring system that addresses not only the spatial arrangement of the finished drawing but also the drawing process of patients with AD by using digital pen data. Methods: A digital pen and tablet were used to copy complex figures. The stroke patterns and kinetics of normal controls (NCs) and patients with early-onset AD (EOAD) and late-onset AD (LOAD) were analyzed by comparing the pen tip trajectory, spatial arrangement, and similarity of the finished drawings. Results: Patients with AD copied the figure in a more fragmented way with a longer pause than NCs (EOAD: P=.045; LOAD: P=.01). Patients with AD showed an increased tendency to draw the figures closer toward the target image in comparison with the NCs (EOAD: P=.005; LOAD: P=.01) Patients with AD showed the lower accuracy than NCs (EOAD: P=.004; LOAD: P=.002). Patients with EOAD and LOAD showed similar but slightly different drawing behaviors, especially in space use and in the initial stage of drawing. Conclusions: The digitalized complex figure test evaluated copying performance quantitatively and further elucidated the patients’ ongoing process during copying. We believe that this novel approach can be used as a digital biomarker of AD. In addition, the repeatability of the test will delineate the process of executive functions and constructional organization abilities with disease progression.
Recent improvements in neuroimaging and molecular markers of Alzheimer’s disease (AD) have aided diagnosis in the early stage of the disease, which greatly increases the chance for successful prevention and treatment. However, the expanding resources for AD diagnosis are unlikely to benefit all elderly due to economic burden. Here, we aimed to develop an inexpensive and sensitive method to detect early-stage AD. A scenario for real-world social event memory test (SEMT) was created and filmed in 360° video. Participants watched the 7-min video through head-mounted display (HMD) and then answered questionnaire about the video. We categorized the SEMT score into recall, recognition, and place-matching scores and compared them to scores on the Mini-Mental State Examination and Seoul Verbal Learning Test. Using the SEMT scores, we built a logistic regression model that discriminated between amyloid positivity and negativity of the participants, with a cross-validation AUC. Furthermore, a classifier was created using support vector machine, which produced 93.8–95.1% sensitivity in classifying individuals into four groups of normal, mild cognitive impairment with or without amyloid, and AD elderly. The high correlation between the SEMT score and amyloid positivity in individuals who experienced virtual social gathering through an HMD opens a new possibility for early diagnosis of AD.
Background and Objectives: Few comparative studies have evaluated wearable single-lead electrocardiogram (ECG) devices and standard multi-lead ECG devices during exercise testing. This study aimed to validate the accuracy of a wearable single-lead ECG monitor for recording heart rate (HR) metrics during graded exercise tests (GXTs). Methods: A cohort of 50 patients at a tertiary hospital underwent GXT while simultaneously being equipped with wearable single- and conventional multi-lead ECGs. The concordance between these modalities was quantified using the intraclass correlation coefficient and Bland–Altman plot analysis. Results: The minimum and average HR readings between the devices were generally consistent. Parameters such as ventricular ectopic beats and supraventricular ectopic beats showed strong agreement. However, the agreement for the Total QRS and Maximum RR was not sufficient. HR measurements across different stages of the exercise test showed sufficient agreement. Although not statistically significant, the standard multi-lead ECG devices exhibited higher noise levels compared to the wearable single-lead ECG devices. Conclusions: Wearable single-lead ECG devices can reliably monitor HR and detect abnormal beats across a spectrum of exercise intensities, offering a viable alternative to traditional multi-lead systems.
A cardiopulmonary exercise test (CPET) is essential for lung resection. However, performing a CPET can be challenging. This study aimed to develop a machine learning model to estimate maximal oxygen consumption (VO2max) using data collected through a patch-type single-lead electrocardiogram (ECG) monitoring device in candidates for lung resection. This prospective, single-center study included 42 patients who underwent a CPET at a tertiary teaching hospital from October 2021 to July 2022. During the CPET, a single-lead ECG monitoring device was applied to all patients, and the results obtained from the machine-learning algorithm using the information extracted from the ECG patch were compared with the CPET results. According to the Bland–Altman plot of measured and estimated VO2max, the VO2max values obtained from the machine learning model and the FRIEND equation showed lower differences from the reference value (bias: −0.33 mL·kg−1·min−1, bias: 0.30 mL·kg−1·min−1, respectively). In subgroup analysis, the developed model demonstrated greater consistency when applied to different maximal stage levels and sexes. In conclusion, our model provides a closer estimation of VO2max values measured using a CPET than existing equations. This model may be a promising tool for estimating VO2max and assessing cardiopulmonary reserve in lung resection candidates when a CPET is not feasible.
BACKGROUND The Rey-Osterrieth Complex Figure Test (RCFT) is a neuropsychological test that is widely used to assess visual memory and visuoconstructional deficits in patients with cognitive impairment, including Alzheimer disease (AD). Patients with AD have an increased tendency for exhibiting extraordinary behaviors in the RCFT for selecting the drawing area, organizing the figure, and deciding the order of images, among other activities. However, the conventional scoring system based on pen and paper has a limited ability to reflect these detailed behaviors. OBJECTIVE This study aims to establish a scoring system that addresses not only the spatial arrangement of the finished drawing but also the drawing process of patients with AD by using digital pen data. METHODS A digital pen and tablet were used to copy complex figures. The stroke patterns and kinetics of normal controls (NCs) and patients with early-onset AD (EOAD) and late-onset AD (LOAD) were analyzed by comparing the pen tip trajectory, spatial arrangement, and similarity of the finished drawings. RESULTS Patients with AD copied the figure in a more fragmented way with a longer pause than NCs (EOAD: P=.045; LOAD: P=.01). Patients with AD showed an increased tendency to draw the figures closer toward the target image in comparison with the NCs (EOAD: P=.005; LOAD: P=.01) Patients with AD showed the lower accuracy than NCs (EOAD: P=.004; LOAD: P=.002). Patients with EOAD and LOAD showed similar but slightly different drawing behaviors, especially in space use and in the initial stage of drawing. CONCLUSIONS The digitalized complex figure test evaluated copying performance quantitatively and further elucidated the patients’ ongoing process during copying. We believe that this novel approach can be used as a digital biomarker of AD. In addition, the repeatability of the test will delineate the process of executive functions and constructional organization abilities with disease progression.
We developed an algorithm that accurately detects P-waves and classifies atrioventricular block (AVB) by applying a semantic segmentation algorithm to an easily attachable single-channel wearable electrocardiogram (ECG).