Zhiyuan Li

Dr. Zhiyuan Li


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 November 2023 in Sensors
Verified
Journal Article
Open access
PDF file
JLJiaming Li
Jiaming Li
LZLeilei Zhang
Leilei Zhang
JWJiaqi Wang
Jiaqi Wang
HSHengyi Su
Hengyi Su
ZWZungang Wang
Zungang Wang
ZLZhiyuan Li
Zhiyuan Li
The uneven energy response of radiation detectors severely limits the accuracy of the dose rate meter used for radiation protection. Currently widely used in dose rate meters as a physical method of setting shielding compensation, the energy response correction error of the detector at different energies is mostly between 15 and 25%. This work designs a real-time correction method for energy response based on a novel Cs3Cu2I5:Tl scintillation detector to improve the accuracy of the dose rate meter used for radiation protection. The technique utilizes the idea of pulse amplitude weighting (PAW) to segment the pulse amplitude histogram. This detector achieves an almost constant energy response after our correction. The experimental results show that compared to 137Cs γ rays, the maximum error of the response is 8.26% in the photon energy ranging from 33 keV to 1.25 MeV, which is much better than ±30% of the recommended IEC 61526:2010, verifying the feasibility of PAW.

1 February 2018 in IOP Conference Series: Earth and Environmental Science
Verified
Conference Paper
Open access
PDF file
ZLZhiyuan Li
Zhiyuan Li
XAXianyun Ai
Xianyun Ai
LFLi Fu
Li Fu
HCHui Cui
Hui Cui
As a kind of special G-M counter, the intense current tube (ICT) is characterized by small ratio of cathode to anode radius, high working current or count rate, and can be used as the detection units of ultra-high range radiation instruments. In this paper, a new design of ICT structure is introduced, not only does it have a minimum ratio of cathode to anode but it also has a cathode which directly sticks out from the sensitive gas. Using COMSOL Multiphysics, we simulated the electric field between the anode and cathode and finalized the optimal structure. The results of processes and experiments show that the structure has better properties, with plateau slope reaching up to 7.4% within 100V, and it also has a wider range of dose rate. The linear data between the bottom limit of 0.2mGy/h and the upper limit of 1Gy/h is quite accurate but it becomes less reliable beyond 1Gy/h. By using Paralyzable model, we deduce that the dead time of the said ICT is less than 13.4 µs, and we will further optimize the readout circuit in order to reduce the resolution time of the circuit in the near future.

20 January 2026 in Sensors
Verified
Journal Article
Open access
PDF file
QLQingyang liu L
Qingyang liu L
JWJiaqi Wang
Jiaqi Wang
YCYe Chen
Ye Chen
ZLZhiyuan Li
Zhiyuan Li
ZWZhenyu Wang
Zhenyu Wang
ZWZungang Wang
Zungang Wang
This paper presents a design for a high-speed digital prototype system for discriminating fast neutrons, thermal neutrons, and γ-rays. The system uses a stilbene–6Li glass composite scintillator with excellent pulse shape discrimination (PSD) properties as the neutron detector. The PSD performance was investigated at different sampling rates, revealing stable performance at rates above 250 MSPS. The system core is a high-speed acquisition board based on the AD9434 analog-to-digital converter (ADC) and the ZYNQ7020 field-programmable gate array (FPGA), which acquires detector signals and implements real-time algorithms. The system was energy-calibrated with 22Na, 137Cs, and 60Co γ-ray sources and evaluated in a n–γ mixed field. Under an 241Am–Be neutron source, the system achieved Figure of Merit (FOM) values of 1.26 for fast neutron/γ, 2.18 for fast neutron/thermal neutron, and 3.25 for γ/thermal neutron discrimination above the 50 keVee electron equivalent energy threshold. These results are consistent with the analysis of down-sampled data from a DT-5730 digitizer, confirming that the system meets its design objectives. Additionally, the measured false alarm rates (FAR) were 0.33% for 60Co, 0.34% for 137Cs, and 0.26% for 22Na. This system integrates waveform discrimination and energy spectrum measurement capabilities, providing a high-performance, cost-effective electronic solution for high-speed signal acquisition and real-time processing in novel composite scintillator neutron detectors.

16 September 2026 in AI & Materials
Verified
Journal Article
Closed access
PDF file
LWLukai Wang
Lukai Wang
SWShenghong Wang
Shenghong Wang
LWLongtao Wu
Longtao Wu
ZWZhenyu Wang
Zhenyu Wang
ZLZhiyuan Li
Zhiyuan Li
ZWZungang Wang
Zungang Wang
Predicting the luminescence behavior of Cs2ZrCl6 crystalline powders with speed and accuracy is a key prerequisite for designing new scintillators aimed at X-ray imaging. Conventional first-principles calculations based on density functional theory can reproduce crystal luminescence, yet they demand substantial computing power and deep materials-domain knowledge, which together translate into high cost, long development cycles, and limited throughput. To sidestep these bottlenecks, our work adopts a machine learning strategy to predict the luminescence properties of Cs2ZrCl6. A training dataset was assembled from the literature and expanded through linear interpolation. The hyperparameters of six regression algorithms, including ridge regression (RR), K-nearest neighbor regression (KNR), support vector regression (SVR), random forest regression (RFR), XGBoost regression (XGBR), and multilayer perceptron regression (MLPR), were tuned by coupling the covariance matrix adaptation evolution strategy (CMA-ES) with 10-fold cross-validation. Once trained, the models captured a reliable composition-structure-property link. By comprehensively evaluating three metrics of the coefficient of determination (R²), mean absolute error (MAE), and mean squared error (MSE), two optimized luminescence property prediction models were identified. The KNR model was selected for emission wavelength prediction, achieving a high R2 of 0.9999 and a low MSE of 1.4434. Meanwhile, the MLPR model was chosen for decay time prediction, with a high R2 of 0.9893 and a low MSE of 0.9234. Additionally, the Shapley Additive exPlanations (SHAP) analysis further quantified feature contributions to target properties, offering physically reasonable interpretations. This work demonstrates the promising capacity of machine learning for fast, reliable prediction of crystal luminescence performance, providing practical support for accelerating materials-oriented research and development.