Mariam Farouk Ghazy

Prof. Dr. Mariam Farouk Ghazy

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 April 2020 in Materials
Verified
Journal Article
Open access
PDF file
OYOMAR MOHAMED MOHAMED YOUSRY
OMAR MOHAMED MOHAMED YOUSRY
MAMetwally A. Abdallah
Metwally A. Abdallah
MGMariam Farouk Ghazy
Mariam Farouk Ghazy
MTMohamed Taman
Mohamed Taman
Mosbeh KaloopMosbeh Kaloop
Mosbeh Kaloop
This research investigates the means to improve the compressive strength of mortar mixtures through using novel mixtures. These mixtures include magnetic water (MW) and fly ash (FA). MW was obtained by circulating tap water (TW) through a magnetic field. The magnetization duration was represented by the number of cycles, the content of FA was replaced with cement, and the super plasticizer percentage (SP) and the curing age were used and evaluated experimentally for producing the mortar mixtures. Mortar flow, crushing compressive strength, and ultrasonic pulse velocity (UPV) tests were applied to evaluate the performances of mixing characteristics. The results demonstrate that the MW-treated mortar mixtures show higher compression strength results than those prepared by TW. The compressive strength was increased up to 60% with 150 cycles, a dose of 0.5% of SP and no FA content at the age of 56 days. The dose of SP can be cut down by a maximum of 40% to 50% in cementitious mortar. the workability was enhanced by a percentage of 70%.

12 October 2021 in Innovative Infrastructure Solutions
Verified
Journal Article
Closed access
PDF file
MGMariam Farouk Ghazy
Mariam Farouk Ghazy
MEMetwally Abd Allah Abd Elaty
Metwally Abd Allah Abd Elaty
MAMohamed Taha Abo-Elenain
Mohamed Taha Abo-Elenain

6 June 2023 in Fire Technology
Verified
Journal Article
Open access
PDF file
MGMariam Farouk Ghazy
Mariam Farouk Ghazy
MEMetwally A. Abd Elaty
Metwally A. Abd Elaty
NZNagat M. Zalhaf
Nagat M. Zalhaf
Reinforced concrete as the most important construction material suffers from long-term deterioration due to different exposure conditions. Fire attack is a critical exposure condition as it can lead to complete collapse of the structure. On the other hand, the repair and strengthening of existing structures have become necessary both technically and financially. Moreover, since high-performance concretes (HPCs) are extensively used as repairing or strengthening materials for different structures, their performance after exposure to elevated temperature needs to be investigated. Therefore, this study is directed to investigate the post-fire flexural behavior of RC slabs cast with traditional normal strength concrete (NSC) and strengthened with HPC. Twenty-one RC slabs were prepared and tested including casting the full thickness with the same mixture (single-concrete slabs) and composite slabs (cast with NSC and HPC). Different variables were considered; using high strength concrete, 30% fly ash, 30% slag, 0.5% polypropylene, 0.5% steel fibers, hybrid fibers (0.5% steel + 0.5% polypropylene), reinforcement ratio, the side exposed to elevated temperature (tension or compression), and joining the HPC layer to the NSC (shear studs or epoxy resin). The slabs were exposed to the required temperature of 600°C for 2 h. The results show that strengthening the RC slab in tension or compression by using HPC remarkably enhanced the slab’s performance after exposure to elevated temperature. Specially, composite slabs containing hybrid fibers in tension side when exposed to elevated temperature from the tension side recorded the highest cracking load, ultimate load, stiffness, toughness, and ductility index as compared to the NSC slab, with increases of 92.8%, 116%, 157%, 335%, and 86.9%, respectively.

15 June 2023 in Innovative Infrastructure Solutions
Verified
Journal Article
Closed access
PDF file
MGMariam Farouk Ghazy
Mariam Farouk Ghazy
MEMetwally A. Abd Elaty
Metwally A. Abd Elaty
MTMohamed Taman
Mohamed Taman
AMAlaa Mehriz
Alaa Mehriz

14 February 2025 in Buildings
Verified
Journal Article
Open access
PDF file
MGMariam Farouk Ghazy
Mariam Farouk Ghazy
MEMetwally Abd Allah Abd Elaty
Metwally Abd Allah Abd Elaty
MSMohamed Abd Elkhalek Sakr
Mohamed Abd Elkhalek Sakr
IAIslam Ali Arafa
Islam Ali Arafa
Sandwich panels, consisting of two concrete wythes that encase an insulating core, are designed to improve energy efficiency and reduce the weight of construction applications. This research examines the thermal and flexural properties of a novel sandwich panel that incorporates ultra-high-performance fiber-reinforced concrete (UHPFRC) and cellular lightweight concrete (CLC) as its core material. Seven sandwich panel specimens were tested for their thermo-flexural performance using four-point bending tests. The experimental parameters included variations in UHPFRC thickness (20 mm and 30 mm) and different shear connector types (shear keys, steel bars, and post-tension steel bars). The study also assessed the effects of adding steel mesh reinforcement to the UHPFRC layer and evaluated the performance of UHPFRC box sections without a CLC core. The analysis concentrated on several critical factors, such as initial, ultimate, and serviceability loads, load–deflection relationships, load–end slip, load–strain relationships, composite action ratios, crack patterns, and failure modes. The thermal properties of the UHPFRC and CLC were evaluated using a transient plane source technique. The results demonstrated that panels using post-tension steel bars as shear connectors achieved flexural performance, and the most favorable composite action ratios reached 68.8%. Conversely, the box section exhibited a brittle failure mode when compared to the other sandwich panels tested. To effectively evaluate mechanical and thermal properties, it is important to design panels that have adequate load-bearing capacity while maintaining low thermal conductivity. This study introduced a thermo-mechanical performance coefficient to evaluate both the thermal and mechanical performance of the panels. The findings indicated that sandwich panels with post-tension steel bars achieved the highest thermo-mechanical performance, while those with steel connectors had the lowest performance.

23 June 2021 in Challenge Journal of Concrete Research Letters
Verified
Journal Article
Closed access
MGMariam Farouk Ghazy
Mariam Farouk Ghazy
MEMetwally Abd Allah Abd Elaty
Metwally Abd Allah Abd Elaty
OKOmar Hussein Khalifa
Omar Hussein Khalifa
The water utilized in concrete manufacture plays an important role within the concrete mix, beginning from controlling the process of hydration of cement, besides appropriate curing to achieve the required strength, not to mention controlling the workability and durability of the concrete structure. The utmost significant challenge for concrete technology is to improve the properties of concrete. Nowadays, the engineering field needs to produce structures in harmony with the concept of sustainable development through the utilization of high-performance materials with an eco-friendly impact that is produced at a low-cost. The magnetic water (MW) provides one of the utmost towards this objective. The cost of magnetizing water is low because of the simple instruments used and the cost can be adapted to the scale of the work. In the last two decades, a new technology, so-called MW technology, has been extended to use in concrete manufacturing. Therefore, currently, the researchers are interested in the use of MW in the manufacture of cementitious materials helping to rationalize the cement usage and reducing reliance on chemical additives that have a negative environmental impact. Consequently, this paper presents the effect of the magnetization process in the structure of water molecules, the main properties of water. Additionally, the effect of using MW on the fresh and mechanical properties, as well as the durability characteristics and performance of cementitious materials have been reviewed. Moreover, the factors that affect the magnetization process of water, which highlighted discuss in this study. The results revealed that using MW significantly enhances the flowability and the characteristic strengths of cementitious materials as well as the durability properties.