The icing on overhead transmission lines is one of the largest threats to the safe operation of electric power systems. Compared with other security accidents in the electric industry, a sudden ice disaster could cause the most serious losses to electric power grids. Among the numerous de-icing and anti-icing techniques for application, direct current ice-melting and mechanical de-icing schemes require power cuts and other restrictive conditions. Superhydrophobic coating technology has been widely focused for good anti-icing properties, low cost and wide application range. However, the special structure of curved transmission lines, complicated service environments, and variated electric performance could significantly limit the application of superhydrophobic anti-icing coatings on overhead transmission lines. In particular, superhydrophobic surfaces can be achieved by combining the rough micro-nano structure and modification agents with low surface energy. Compared with superhydrophobic coatings, superhydrophobic surfaces will not increase the weight of the substrate and have good durability and stability in maintaining the robust structure to repeatedly resist aging, abrasion, corrosion and corona damages, etc. Therefore, this review summarizes the theoretical basis of anti-icing behavior and mechanisms, influencing factors of anti-icing properties, potential techniques of superhydrophobic surfaces on transmission lines, and, finally, presents future development challenges and prospects of superhydrophobic surfaces in the anti-icing protection of overhead transmission lines.
Icing on transmission lines greatly threatens the operation and security of power systems. In this study, a novel durable anti-icing aluminum (Al) conductor is first proposed for its robust anti-icing properties and improved electrical performance. The novel Al conductor with optimized nanopores structure fabricated by anodization presented excellent superhydrophobicity with a contact angle of 176.83° and a contact angle hysteresis of 0.55°. Meanwhile, the ultra-low ice adhesion (1.75 kPa) of novel Al conductors, which is less than 1% of that of bare Al conductors, showed potential for self-de-icing behavior in glaze ice. Novel conductors also exhibited thinner glaze ice accretion of 5.84 g, than that of bare conductors (62.70 g). Additionally, the durability of novel conductors was examined in 100 times frosting/defrosting cycles, 100 times icing/de-icing cycles and 900 times abrasion processes. The mechanisms of robust durability were attributed to the excellent wear resistance and the continuous replenishment of modification agents. Fortunately, the good electrical performance of novel conductors in operation including the corona performance and line loss was experimental measured and validated by previous numerical theoretical calculations. In this study, the novel anti-icing Al conductors show profound application potential in high-voltage transmission fields.
Recently, the icing disaster of transmission lines has been a serious threat to the safe operation of the power system. A superhydrophobic (SHP) anti-icing surface with a honeycomb nanopore structure was constructed using anodic oxidation technology combined with a vacuum infusion process. When the current density was 87.5 mA/cm2, the honeycomb porous surface had the best superhydrophobic performance (excellent water mobility), lowest ice-adhesion strength (0.7 kPa) and best anti-frosting performance. Compared with other types of alumina surfaces, the ice-adhesion strength of the SHP surface (87.5 mA/cm2) was only 0.2% of that of the bare surface. The frosting time of the SHP surface (87.5 mA/cm2) was 150 min, which was much slower. The former is attributed to the air cushion within the porous structure and the stress concentration, and the latter is attributed to the self-transition of the droplets and low solid–liquid heat transfer area. After 100 icing or frosting cycles, the SHP surface (87.5 mA/cm2) maintained a low ice-adhesion strength and superhydrophobic performance. This is because the anodic oxidation process forms a hard porous film, and the nano porous structure with a high aspect ratio can store modifiers to realize self-healing. The results indicate that the SHP surface with a honeycomb nanopore structure presents excellent anti-icing performance and durability.
In this study, we introduced a novel environmentally-friendly electrolyte consisting of polytetrafluoroethylene (PTFE) nanoparticles and malic acid solution to fabricate composite anodic film on Ti-10V-2Fe-3Al alloy at different electrolyte temperatures. The morphology revealed that the PTFE nanoparticles were successfully incorporated into composite anodic films and embedded preferentially in the pores and cracks. Their performances (wear, corrosion and hydrophobicity) were evaluated via electrochemical tests, ball on disc tests, and a contact angle (CA) meter. Compared to the substrate of titanium alloy Ti-10V-2Fe-3Al, the composite anodic films exhibited the low wear rates, high corrosion resistance and good hydrophobicity. However, the microstructure and morphology of the films were affected by the electrolyte temperature. As a result, their performances were changed greatly as a function of the temperature and the film fabricated at 20 °C exhibited better performances (CA = 131.95, icorr = 6.75 × 10−8 A·cm−2, friction coefficient = 0.14) than those at other electrolyte temperatures. In addition, the corresponding lubrication mechanism of the composite anodic films was discussed.