Ice accumulation on glass insulators is likely to cause faults such as flashover, tripping and power failure, which interfere with the normal operation of the power grid. Accordingly, superhydrophobic coatings with great anti-icing potential have received much attention. In this study, three superhydrophobic coatings (PTFE, Al2O3 and SiO2) were successfully prepared on glass surfaces by using one-step spraying. The microscopic morphology, wettability, anti-icing and anti-glaze icing properties of the superhydrophobic coatings were comparatively analyzed. The results indicated that the PTFE coating had a densely distributed rough structure, showing a contact angle of 165.5° and a sliding angle of 3.1°. The water droplets on the surface could rebound five times. Compared with the Al2O3 and SiO2 coatings, the anti-icing performance of the PTFE coating was significantly improved. The freezing time was far more than 16 times that of glass (4898.7 s), and the ice adhesion strength was 9 times lower than that of glass (27.5 kPa). The glaze icing test in the artificial climate chamber showed that the icing weight of the PTFE coating was 1.38 g, which was about 32% lower than that of the glass. In addition, the icing/melting and abrasion cycles destroyed the low-surface-energy substances and nanostructures on the surface, leading to the degradation of the anti-icing durability of the PTFE coatings. However, the PTFE coating still maintained excellent hydrophobicity and anti-icing properties after UV irradiation for up to 624 h. The superhydrophobic coatings prepared in this work have promising development prospects and offer experimental guidance for the application of anti-icing coatings on glass insulators.
The icing of glass insulators is likely to cause faults such as insulator flashover, which poses a serious threat to the power system. Traditional deicing techniques have the disadvantage of being costly and inefficient. Herein, polytetrafluoroethylenes (PTFEs) as nanoparticles and epoxy and fluorosilicone resins as binders were blended to construct an anti-icing coating. The superhydrophobic (SHP) epoxy/fluorosilicone/PTFE coatings for anti-icing were successfully prepared on glass slides through one-step spraying. The effect of PTFE mass fraction on the microstructure, on the wettability and on the anti-icing properties of the coatings was investigated. The results showed that the coatings with different PTFE mass fractions had different microstructures. When the PTFE mass fraction was 47.2%, the SHP coating exhibited a uniform rough structure with an apparent contact angle as high as 164.7° and a sliding angle as low as 3.2°. Moreover, the water droplets can bounce back five times with a contact time of only 9.5 ms and a rebound height of 4.58 mm. In the low-temperature environment (−10 °C), the SHP coating displayed good anti-frosting, anti-icing and icephobic properties. The delayed frosting time (1499 s) and delayed freezing time (1295.3 s) of the SHP coating were three and five times longer than those of the glass, respectively. The SHP coating presented an ice-adhesion strength (39.8 kPa) that was six times lower than that of glass. The prepared SHP coating demonstrated potential applications for the anti-icing of glass insulators.
Recently, the icing disaster of transmission lines has been a serious threat to the safe operation of the power system. A superhydrophobic (SHP) anti-icing surface with a honeycomb nanopore structure was constructed using anodic oxidation technology combined with a vacuum infusion process. When the current density was 87.5 mA/cm2, the honeycomb porous surface had the best superhydrophobic performance (excellent water mobility), lowest ice-adhesion strength (0.7 kPa) and best anti-frosting performance. Compared with other types of alumina surfaces, the ice-adhesion strength of the SHP surface (87.5 mA/cm2) was only 0.2% of that of the bare surface. The frosting time of the SHP surface (87.5 mA/cm2) was 150 min, which was much slower. The former is attributed to the air cushion within the porous structure and the stress concentration, and the latter is attributed to the self-transition of the droplets and low solid–liquid heat transfer area. After 100 icing or frosting cycles, the SHP surface (87.5 mA/cm2) maintained a low ice-adhesion strength and superhydrophobic performance. This is because the anodic oxidation process forms a hard porous film, and the nano porous structure with a high aspect ratio can store modifiers to realize self-healing. The results indicate that the SHP surface with a honeycomb nanopore structure presents excellent anti-icing performance and durability.
Globally escalating electricity demand necessitates substantial power grid capacity expansion. Current transmission line capacity enhancement technologies are seriously constrained by factors including limited accuracy of computational models, elevated line losses, requirements for new line construction, and substantial capital investment. Capacity-uprating conductors, recognized for their superior current-carrying performance and cost-effective retrofitting, represent one of the most viable solutions for transmission augmentation. However, their large-scale deployment remains impeded by increased line losses and high costs. This review systematically analyses critical constraints on transmission line ampacity through computational modeling and elucidates conductor heat dissipation pathways. Based on this foundation, we synthesize recent advancements in capacity-uprating conductors across three key dimensions: structural optimization, material engineering, and passive radiative cooling technologies. We concurrently evaluate their applications in power transmission projects and explore promising future development directions. This review aims to provide a theoretical foundation, guiding next-generation capacity enhancement solutions for grid modernization.
Icing on transmission lines often causes potential electric damage in power systems. Superhydrophobic anodized Al conductors have been proposed to have good anti-icing properties. In this study, superhydrophobic anodized Al conductors with composite nanopore structures were prepared by a two-step anodization. The microstructure, hydrophobicity, and anti-icing properties of composite nanopore structures were compared and studied. The optimal preparation parameter was determined as a current density of 0.04375 A/cm2 and anodization time of 15 min. Compared with the bare substrate, the optimal anodized Al surface of the composite nanopore structures show excellent hydrophobic and anti-icing properties, including a contact angle of 173°, a contact angle hysteresis of 0.122°, an ice adhesion strength of 0.71 kPa, and a glaze icing weight of 0.1 g after the 8 h. Therefore, the prepared anodized Al surface of composite nanopore structures with good anti-icing properties has profound application potential for overhead transmission lines.
Enhancing the ampacity of existing overhead transmission conductors through surface heat-dissipation regulation is important for grid capacity expansion. Herein, a superhydrophobic radiative heat-dissipating conductor was fabricated by combining phosphoric acid anodization with low-surface-energy modification. Porous anodic aluminum oxide (AAO) layers were in situ constructed on ACSR conductors under different anodizing current densities and oxidation times, followed by modification with hexadecyltrimethoxysilane or 1H,1H,2H,2H-perfluorodecyltrimethoxysilane to obtain H-AAO and F-AAO conductors, respectively. The surface morphology, optical properties, wettability, electrical resistance, current-induced temperature rise, and aging stability were systematically evaluated. The porous AAO layer enhanced the broadband infrared emissivity of the conductor surface while maintaining relatively high solar-band reflectance. The F-AAO conductor exhibited a water contact angle of 164.9° and a sliding angle of 1.8°, confirming excellent super-hydrophobicity. At 450 A, the steady-state temperature of the F-AAO conductor decreased from 106.85 °C for the Bare conductor to 75.34 °C. Under a 70 °C temperature limit, the allowable current increased from 343.58 to 431.57 A, corresponding to a 25.6% enhancement. Moreover, the F-AAO conductor retained stable heat-dissipation performance after 28 days of thermal aging. These findings demonstrate that anodization-assisted surface engineering is a feasible strategy for improving radiative heat dissipation, environmental adaptability, and current-carrying performance of overhead transmission conductors.