Fernando Leyton

Dr. Fernando Leyton

orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 January 2009 in Pediatric Cardiology
Verified
Journal Article
Closed access
PDF file
EVEliseo Vano
Eliseo Vano
CUCarlos Ubeda
Carlos Ubeda
FLFernando Leyton
Fernando Leyton
PMPatricia Miranda
Patricia Miranda
LGLuciano Gonzalez
Luciano Gonzalez

8 July 2008 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
EVEliseo Vano
Eliseo Vano
CUCarlos Ubeda
Carlos Ubeda
FLFernando Leyton
Fernando Leyton
PMP Miranda
P Miranda
Radiation dose and image quality for paediatric protocols in a biplane x-ray system used for interventional cardiology have been evaluated. Entrance surface air kerma (ESAK) and image quality using a test object and polymethyl methacrylate (PMMA) phantoms have been measured for the typical paediatric patient thicknesses (4-20 cm of PMMA). Images from fluoroscopy (low, medium and high) and cine modes have been archived in digital imaging and communications in medicine (DICOM) format. Signal-to-noise ratio (SNR), figure of merit (FOM), contrast (CO), contrast-to-noise ratio (CNR) and high contrast spatial resolution (HCSR) have been computed from the images. Data on dose transferred to the DICOM header have been used to test the values of the dosimetric display at the interventional reference point. ESAK for fluoroscopy modes ranges from 0.15 to 36.60 mu Gy/frame when moving from 4 to 20 cm PMMA. For cine, these values range from 2.80 to 161.10 mu Gy/frame. SNR, FOM, CO, CNR and HCSR are improved for high fluoroscopy and cine modes and maintained roughly constant for the different thicknesses. Cumulative dose at the interventional reference point resulted 25-45% higher than the skin dose for the vertical C-arm (depending of the phantom thickness). ESAK and numerical image quality parameters allow the verification of the proper setting of the x-ray system. Knowing the increases in dose per frame when increasing phantom thicknesses together with the image quality parameters will help cardiologists in the good management of patient dose and allow them to select the best imaging acquisition mode during clinical procedures.

12 April 2012 in Medical Physics
Verified
Journal Article
Closed access
CUCarlos Ubeda
Carlos Ubeda
EVEliseo Vano
Eliseo Vano
PMPatricia Miranda
Patricia Miranda
FLFernando Leyton
Fernando Leyton

16 February 2010 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
PDF file
CUCarlos Ubeda
Carlos Ubeda
EVEliseo Vano
Eliseo Vano
LGLuciano Gonzalez
Luciano Gonzalez
PMPatricia Miranda
Patricia Miranda
EVEdith Valenzuela
Edith Valenzuela
COCarlos Oyarzun
Carlos Oyarzun
Interventional cardiology procedures usually imply high doses to the staff, as paediatric cardiologists need to stay closer to the patient than during adult procedures. Also, biplane systems are used that imply an additional source of staff doses. The objective of this paper is to measure scatter doses in four X-ray systems, using polymethyl methacrylate phantoms with thicknesses ranging from 4 to 16 cm to simulate paediatric patients, for the different acquisition modes. Scatter dose rates measured at the position of cardiologist's eyes ranged from 0.8 to 12 mSv h−1, and about twice the above values at lower extremities, as a linear function of the surface air kerma at the phantom, keeping the irradiated area constant. Therefore, the respective personal dose equivalent for the lens of the eyes may be around 0.5 and 1 mSv throughout the procedure, if additional protection is not used. Simultaneous cine acquisition in biplane systems yielded scatter doses to cardiologists, increased by factors from 5 to 21, compared with a single C-arm acquisition case and depending on geometry. Knowledge of scatter doses for different operation modes, patient thicknesses and the biplane operation should help paediatric cardiologists to adopt conservative attitudes in respect of their occupational radiation risks.

1 September 2011 in Health Physics
Verified
Journal Article
Closed access
EVEliseo Vano
Eliseo Vano
CUCarlos Ubeda
Carlos Ubeda
PMPatricia Miranda
Patricia Miranda
FLFernando Leyton
Fernando Leyton
ADAriel Durán
Ariel Durán
ANAlejandro Nader
Alejandro Nader
The aim of this work is to present a methodology and some initial results for a pilot program on radiation protection (RP) in pediatric interventional cardiology under the auspices of the International Atomic Energy Agency. The starting point of the program was a workshop involving several pediatric cardiologists leading this specialty in 11 Latin American countries. The workshop included a pilot RP training course and additional sessions during which the objectives of the program and the methodology to collect and process data on patient and staff radiation doses were discussed. Special attention was dedicated to agree on a common quality control (QC) protocol for the x-ray and imaging systems used in the different catheterization laboratories. The preliminary data showed that only 64% of the cardiologists used their personal dosimeters regularly and that only 36% were aware of their personal dose values. The data on pediatric interventional activity were collected from 10 centers from nine different countries. A total of 2,429 procedures (50% diagnostic and 50% therapeutic) were carried out during 2009 in these centers. Patient dose data were available in only a few centers and were not analyzed on a regular basis in any of the catheterization laboratories involved. Plans were developed for a basic QC protocol of the x-ray systems and construction of a Latin American database on pediatric cardiology with patient and staff dose values with the idea in mind of obtaining distributions of these dose values before promoting several optimization strategies.

1 November 2016 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
FLFernando Leyton
Fernando Leyton
MNMaria S. Nogueira
Maria S. Nogueira
LGLuiz A. Gubolino
Luiz A. Gubolino
MPMakyson R. Pivetta
Makyson R. Pivetta
CUCarlos Ubeda
Carlos Ubeda