Gautam Anand

Dr. Gautam Anand

Auckland University of Technology
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 February 2024 in Sensors
Verified
Journal Article
Open access
PDF file
EDEkta Dahiya
Ekta Dahiya
Anubha KalraAnubha Kalra
Anubha Kalra
ALAndrew Lowe
Andrew Lowe
Gautam AnandGautam Anand
Gautam Anand
In the rapidly evolving landscape of continuous electrocardiogram (ECG) monitoring systems, there is a heightened demand for non-invasive sensors capable of measuring ECGs and detecting heart rate variability (HRV) in diverse populations, ranging from cardiovascular patients to sports enthusiasts. Challenges like device accuracy, patient privacy, signal noise, and long-term safety impede the use of wearable devices in clinical practice. This scoping review aims to assess the performance and safety of novel multi-channel, sensor-based biopotential wearable devices in adults. A comprehensive search strategy was employed on four databases, resulting in 143 records and the inclusion of 12 relevant studies. Most studies focused on healthy adult subjects (n = 6), with some examining controlled groups with atrial fibrillation (AF) (n = 3), long QT syndrome (n = 1), and sleep apnea (n = 1). The investigated bio-sensor devices included chest-worn belts (n = 2), wrist bands (n = 2), adhesive chest strips (n = 2), and wearable textile smart clothes (n = 4). The primary objective of the included studies was to evaluate device performance in terms of accuracy, signal quality, comparability, and visual assessment of ECGs. Safety findings, reported in five articles, indicated no major side effects for long-term/continuous monitoring, with only minor instances of skin irritation. Looking forward, there are ample opportunities to enhance and test these technologies across various physical activity intensities and clinical conditions.

1 March 2021 in Physiological Measurement
Verified
Journal Article
Closed access
Gautam AnandGautam Anand
Gautam Anand
YYYang Yu
Yang Yu
ALAndrew Lowe
Andrew Lowe
Anubha KalraAnubha Kalra
Anubha Kalra
Recent advances in hemodynamic monitoring have seen the advent of non-invasive methods which offer ease of application and improve patient comfort. Bioimpedance Analysis or BIA is one of the currently employed non-invasive techniques for hemodynamic monitoring. Impedance Cardiography (ICG), one of the implementations of BIA, is widely used as a non-invasive procedure for estimating hemodynamic parameters such as stroke volume (SV) and cardiac output (CO). Even though BIA is not a new diagnostic technique, it has failed to gain consensus as a reliable measure of hemodynamic parameters. Several devices have emerged for estimating CO using ICG which are based on evolving methodologies and techniques to calculate SV. However, the calculations are generally dependent on the electrode configurations (whole body, segmental or localised) as well as the accuracy of different techniques in tracking blood flow changes. Blood volume changes, concentration of red blood cells, pulsatile velocity profile and ambient temperature contribute to the overall conductivity of blood and hence its impedance response during flow. There is a growing interest in investigating limbs for localised BIA to estimate hemodynamic parameters such as pulse wave velocity. As such, this paper summarises the current state of hemodynamic monitoring through BIA in terms of different configurations and devices in the market. The conductivity of blood flow has been emphasized with contributions from both volume and velocity changes during flow. Recommendations for using BIA in hemodynamic monitoring have been mentioned highlighting the suitable range of frequencies (1 kHz–1 MHz) as well as safety considerations for a BIA setup. Finally, current challenges in using BIA such as geometry assumption and inaccuracies have been discussed while mentioning potential advantages of a multi-frequency analysis to cover all the major contributors to blood’s impedance response during flow.

5 December 2023 in Biosensors and Bioelectronics: X
Verified
Journal Article
Open access
Yang YuYang Yu
Yang Yu
BJBhavya Jain
Bhavya Jain
Gautam AnandGautam Anand
Gautam Anand
MHMahdi Heidarian
Mahdi Heidarian
ALAndrew Lowe
Andrew Lowe
AKAnubha Kalra
Anubha Kalra

1 March 2019 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
Gautam AnandGautam Anand
Gautam Anand
ALAndrew Lowe
Andrew Lowe
AAAhmed Al-Jumaily
Ahmed Al-Jumaily

1 January 2016 in Journal of Electrical Bioimpedance
Verified
Journal Article
Open access
PDF file
Gautam AnandGautam Anand
Gautam Anand
ALAndrew Lowe
Andrew Lowe
AAAhmed M. Al-Jumaily
Ahmed M. Al-Jumaily
This work presents a simulation analysis of the bioimpedance measurements at the human forearm. The Ansys® High Frequency Structure Simulator (HFSS) has been used to analyze the electrical response of a section of human forearm with three domains of dielectric behavior – fat, muscle and artery (blood). The impedance values were calculated as the ratio of the output voltage at the electrodes to the applied known current (1 mA). A model was developed and was simulated for impedance values obtained within a frequency range of 1 kHz to 2 MHz. The measurements were done at three instances of radial artery diameter. The maximum resistance and reactance values were calculated as 445 Ω and 178.5 Ω, 356 Ω and 138 Ω, and 368 Ω and 144.3 Ω for diameters 2.3 mm, 2.35 mm, and 2.4 mm respectively. The set of impedance values obtained followed the Cole-plot trend. The results obtained were found to be in excellent agreement with the Cole modelling. The set of values obtained at three different diameters reflected the effect of blood flow on impedance values.

1 February 2023 in Sensors
Verified
Journal Article
Open access
PDF file
HZHuiyang Zhang
Huiyang Zhang
Anubha KalraAnubha Kalra
Anubha Kalra
ALAndrew Lowe
Andrew Lowe
Yang YuYang Yu
Yang Yu
Gautam AnandGautam Anand
Gautam Anand
Recent advancement in wearable and robot-assisted healthcare technology gives rise to the demand for smart interfaces that allow more efficient human-machine interaction. In this paper, a hydrogel-based soft sensor for subtle touch detection is proposed. Adopting the working principle of a biomedical imaging technology known as electrical impedance tomography (EIT), the sensor produces images that display the electrical conductivity distribution of its sensitive region to enable touch detection. The sensor was made from a natural gelatin hydrogel whose electrical conductivity is considerably less than that of human skin. The low conductivity of the sensor enabled a touch-detection mechanism based on a novel short-circuiting approach, which resulted in the reconstructed images being predominantly affected by the electrical contact between the sensor and fingertips, rather than the conventionally used piezoresistive response of the sensing material. The experimental results indicated that the proposed sensor was promising for detecting subtle contacts without the necessity of exerting a noticeable force on the sensor.