This study describes a new method for analyzing microcirculatory videos. It introduces algorithms for quantitative assessment of vessel length, diameter, the functional microcirculatory density distribution and red blood-cell (RBC) velocity in individual vessels as well as its distribution. The technique was validated and compared to commercial software. The method was applied to the sublingual microcirculation in a healthy volunteer and in a patient during cardiac surgery. Analysis time was reduced from hours to minutes compared to previous methods requiring manual vessel identification. Vessel diameter was detected with high accuracy (>80%, d > 3 pixels). Capillary length was estimated within 5 pixels accuracy. Velocity estimation was very accurate (>95%) in the range [2.5, 1,000] pixels/s. RBC velocity was reduced by 70% during the first 10 s of cardiac luxation. The present method has been shown to be fast and accurate and provides increased insight into the functional properties of the microcirculation.
The accuracy of additive manufactured medical constructs is limited by errors introduced during image segmentation. The aim of this study was to review the existing literature on different image segmentation methods used in medical additive manufacturing. Thirty-two publications that reported on the accuracy of bone segmentation based on computed tomography images were identified using PubMed, ScienceDirect, Scopus, and Google Scholar. The advantages and disadvantages of the different segmentation methods used in these studies were evaluated and reported accuracies were compared. The spread between the reported accuracies was large (0.04 mm - 1.9 mm). Global thresholding was the most commonly used segmentation method with accuracies under 0.6 mm. The disadvantage of this method is the extensive manual post-processing required. Advanced thresholding methods could improve the accuracy to under 0.38 mm. However, such methods are currently not included in commercial software packages. Statistical shape model methods resulted in accuracies from 0.25 mm to 1.9 mm but are only suitable for anatomical structures with moderate anatomical variations. Thresholding remains the most widely used segmentation method in medical additive manufacturing. To improve the accuracy and reduce the costs of patient-specific additive manufactured constructs, more advanced segmentation methods are required.
Malunion after a distal radius fracture is very common and if symptomatic, is treated with a so-called corrective osteotomy. In a traditional distal radius osteotomy, the radius is cut at the fracture site and a wedge is inserted in the osteotomy gap to correct the distal radius pose. The standard procedure uses two orthogonal radiographs to estimate the two inclination angles and the dimensions of the wedge to be inserted into the osteotomy gap. However, optimal correction in 3-Dspace requires restoring three angles and three displacements. This paper introduces a new technique that uses preoperative planning based on 3-D images. Intraoperative 3-D imaging is also used after inserting pins with marker tools in the proximal and distal part of the radius and before the osteotomy. Positioning tools are developed to correct the distal radius pose in six degrees of freedom by navigating the pins. The method is accurate (d err <; 1.2 mm, φ err <; 0.9°, mTRE = 1.7 mm), highly reproducible (SE d <; 1.0 mm, SE φ ≤ 1.4°, SE mTRE = 0.7 mm), and allows intraoperative evaluation of the end result. Small incisions for pin placement and for the osteotomy render the method minimally invasive.
Regular blood transfusion is the cornerstone of care for patients with red blood cell (RBC) disorders such as thalassaemia or sickle‐cell disease. With repeated transfusion, alloimmunisation often occurs due to incompatibility at the level of minor blood group antigens. We use CRISPR‐mediated genome editing of an immortalised human erythroblast cell line (BEL‐A) to generate multiple enucleation competent cell lines deficient in individual blood groups. Edits are combined to generate a single cell line deficient in multiple antigens responsible for the most common transfusion incompatibilities: ABO (Bombay phenotype), Rh (Rh null ), Kell ( K0 ), Duffy (Fy null ), GPB (S−s−U−). These cells can be differentiated to generate deformable reticulocytes, illustrating the capacity for coexistence of multiple rare blood group antigen null phenotypes. This study provides the first proof‐of‐principle demonstration of combinatorial CRISPR‐mediated blood group gene editing to generate customisable or multi‐compatible RBCs for diagnostic reagents or recipients with complicated matching requirements.