Handdeut Chang

Handdeut Chang

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 June 2020 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
JKJung Kim
Jung Kim
YNYoungjin Na
Youngjin Na
DLDong Yeon Lee
Dong Yeon Lee
HCHanddeut Chang
Handdeut Chang
JKJung Kim
Jung Kim
For active AFO applications, pneumatic remote transmission has advantages in minimizing the mass and complexity of the system due to the flexibility in placing pneumatic components and providing high back-drivability via simple valve control. However, pneumatic systems are generally tethered to large stationary air compressors, which greatly limit the practical daily usage. In this study, we implemented a wearable custom compressor that can be worn at the trunk of the body and can generate up to 1050 kPa of pressurized air to power an unilateral active AFO for dorsiflexion (DF) assistance of drop-foot patients. In order to minimize the size and weight of the custom compressor, the compression rate of the custom compressor was optimized to the rate of consumption required to power the active AFO. The finalized system can provide a maximum assistive torque of 9.8 Nm at a functional frequency of 1 Hz and the average resistive torque during free movement was 0.03 Nm. The system was tested for five hemiplegic drop-foot patients. The proposed system showed an average improvement of 12.3° of ankle peak dorsiflexion angle during the mid to late swing phase.

11 May 2022 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
HJHyerim Jeon
Hyerim Jeon
QLQuang Ngoc Le
Quang Ngoc Le
SJSanghun Jeong
Sanghun Jeong
SJSujin Jang
Sujin Jang
Hoeryong JungHoeryong Jung
Hoeryong Jung
YKYeongjin Kim
Yeongjin Kim
A flexible surgical robot that can adjust its stiffness guarantees safe operation by satisfying both the high flexibility required when the robot approaches a surgical target and the more stiffness necessary for the end effector to perform surgical procedures. Therefore, this paper proposes a flexible surgical robot that consists of a central backbone, eight super-elastic wires as peripheral backbones, SMA springs, rubber tubes, and several disks. The inner diameter of the SMA springs that can be changed via their temperature creates a tightening force change to apply onto the eight backbone wires of the robot to adjust the overall stiffness of the robot. The simple structure is favorable for robot miniaturization. Frictional force and stiffness modulation experiments of the robot are performed. The results confirmed that the robot's stiffness was increased approximately 1.4 times between the martensite state and the austenite state of the SMA spring. The relationship model between the flexural rigidity of the robot and the frictional force between the SMA spring with the peripheral backbones is established. We compared the flexural rigidity values obtained from our model with those of the experimental result and confirmed that the model was valid.

10 August 2018 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
JKJung Kim
Jung Kim
HCHanddeut Chang
Handdeut Chang
JPJunghoon Park
Junghoon Park
JKJung Kim
Jung Kim
Despite the rapid advances in soft robotic actuation technologies, the main energy source that powers most wearable systems remains the conventional tethered stationary air compressor that greatly limits these systems’ applicability. Several portable pneumatic energy sources have been introduced; however, the limited maximum output pressure and flow rate, size and weight, large operational noise, and potential safety hazards must still be resolved before being applied to current wearable applications. In this study, we propose the design of a portable double-piston crank microcompressor that can generate up to a maximum gauge output pressure of 986 kPa and a maximum flow rate of 9.78 L/min, while maintaining a simple structure, static mass of 1.5 kg and not generating any safety hazards. The design requirements in terms of maximum pressure and flow rate were optimized based on wearable robotic applications. The sound intensity level generated by the developed microcompressor was approximately 65 dB, which can be used for long-term usage, at maximum flow rate when measured from a 0.5 m distance.

19 March 2019 in IEEE Transactions on Robotics
Verified
Journal Article
Closed access
HCHanddeut Chang
Handdeut Chang
SKSangjoon J. Kim
Sangjoon J. Kim
JKJung Kim
Jung Kim
High mechanical impedance, sensor resolution, and computing bandwidth are desirable for achieving stability in feedback control. In contrast, although the human body is physically inferior to man-made systems in terms of feedback control due to signal transmission delay, humans can achieve not only stable but also robust and adaptive control ability. For these reasons, the significance of the feedforward control of the human has been emphasized in neuroscience. In previous studies, virtual trajectory control and internal model hypotheses were used to explain the principle of human feedforward control in view of the mechanical stiffness of joints and the internal model of the brain, respectively. Inspired by these insights, in this paper, we focus on the relationship between the joint stiffness and inverse model accuracy and attempted to apply it to the field of robotics. We present a variable stiffness actuator developed using variable radius gear transmission inspired by muscle cross-bridge kinematics. The developed mechanism allows the joint stiffness to be accurately controlled without any sensor-based feedback control. Using the developed actuator, we conduct a feedforward motion generating experiment with respect to variations in the inverse dynamics model uncertainty and verified that joint stiffness can compensate for inverse model uncertainty and external disturbances. These results indicate that the developed variable stiffness actuator can be applied to the robotics field for feedforward applications and support the hypothesis that humans may utilize joint stiffness to compensate for the inverse dynamics model uncertainty.

21 April 2022 in International Journal of Precision Engineering and Manufacturing
Verified
Journal Article
Closed access
PDF file
QLQuang Ngoc Le
Quang Ngoc Le
HKHyunho Kim
Hyunho Kim
SJSanghun Jeong
Sanghun Jeong
HCHanddeut Chang
Handdeut Chang
HPHardik J. Pandya
Hardik J. Pandya
YKYeongjin Kim
Yeongjin Kim

23 November 2023 in Actuators
Verified
Journal Article
Open access
PDF file
HKHyunho Kim
Hyunho Kim
SJSujin Jang
Sujin Jang
TDThien Phuoc Do
Thien Phuoc Do
CLChang Kee Lee
Chang Kee Lee
BABummo Ahn
Bummo Ahn
YKYeongjin Kim
Yeongjin Kim
As the number of patients with amputations increases, research on assistive devices such as prosthetic limbs is actively being conducted. However, the development of assistive devices for patients with partial amputations is insufficient. In this study, we developed a finger prosthesis for patients with partial amputations. The design and mathematical modeling of the prosthesis are briefly presented. A pneumatic actuator, based on the McKibben muscle design, was employed to drive the finger prosthesis. We characterized the relationship between the actuator’s force and axial length changes with varying pressure. An empirical model derived from conventional mathematical modeling of force and axis length changes was proposed and compared with experimental data, and the error was measured to be between about 3% and 13%. In order to control the actuator using an electromyography (EMG) signal, an electrode was attached to the user’s finger flexors. The EMG signal was measured in relation to the actual gripping force and was provided with visual feedback, and the magnitude of the signal was evaluated using root mean square (RMS). Depending on the evaluated EMG signal magnitude, the pressure of the actuator was continuously adjusted. The pneumatic pressure was adjusted between 100 kPa and 250 kPa, and the gripping force of the finger prosthesis ranged from about 0.7 N to 6.5 N. The stiffness of the prosthesis can be varied using the SMA spring. The SMA spring is switched to a fully austenite state at 50 °C through PID control, and when the finger prosthesis is bent to a 90° angle, it can provide approximately 1.2 N of assistance force. Finally, the functional evaluation of the finger prosthesis was performed through a pinch grip test of eight movements.