It has been the dream of many scientists and engineers to realize a non-contact remote sensing system that can perform continuous, accurate and long-term monitoring of human vital signs as we have seen in many Sci-Fi movies. Having an intelligible sensor system that can measure and record key vital signs (such as heart rates and respiration rates) remotely and continuously without touching the patients, for example, can be an invaluable tool for physicians who need to make rapid life-and-death decisions. Such a sensor system can also effectively help physicians and patients making better informed decisions when patients’ long-term vital signs data is available. Therefore, there has been a lot of research activities on developing a non-contact sensor system that can monitor a patient’s vital signs and quickly transmit the information to healthcare professionals. Doppler-based radio-frequency (RF) non-contact vital signs (NCVS) monitoring system are particularly attractive for long term vital signs monitoring because there are no wires, electrodes, wearable devices, nor any contact-based sensors involved so the subjects may not be even aware of the ubiquitous monitoring. In this paper, we will provide a brief review on some latest development on NCVS sensors and compare them against a few novel and intelligent phased-array Doppler-based RF NCVS biosensors we have built in our labs. Some of our NCVS sensor tests were performed within a clutter-free anechoic chamber to mitigate the environmental clutters, while most tests were conducted within the typical Herman-Miller type office cubicle setting to mimic a more practical monitoring environment. Additionally, we will show the measurement data to demonstrate the feasibility of long-term NCVS monitoring. The measured data strongly suggests that our latest phased array NCVS system should be able to perform long-term vital signs monitoring intelligently and robustly, especially for situations where the subject is sleeping without hectic movements nearby.
1 January 2018 in Wireless Communications and Mobile Computing
The 5G wireless revolution presents some dramatic challenges to the design of handsets and communication infrastructures, as 5G targets higher than 10 Gbps download speed using millimeter‐wave (mm‐Wave) spectrum with multiple‐input multiple‐output (MIMO) antennas, connecting densely deployed wireless devices for Internet‐of‐Everything (IoE), and very small latency time for ultrareliable machine type communication, etc. The broadband modulation bandwidth for 5G RF transmitters (i.e., maximum possibly even above 1 GHz) demands high‐power efficiency and stringent linearity from its power amplifier (PA). Additionally, the phased‐array MIMO antennas with numerous RF front‐ends (RFFEs) will require unprecedented high integration level with low cost, making the design of 5G PA one of the most challenging tasks. As the centimeter‐wave (cm‐Wave) 5G systems will probably be deployed on the market earlier than their mm‐Wave counterparts, we will review in this paper the latest development on 15 GHz and 28 GHz 5G cm‐Wave PAs extensively, while also covering some key mm‐Wave PAs in the literature. Our review will focus on the available options of device technologies, novel circuit and system architectures, and efficiency enhancement techniques at power back‐off for 5G PA design.
29 November 2010 in IEEE Transactions on Circuits and Systems I: Regular Papers
This paper discusses the circuits and system design methodology of a highly-efficient wideband RF polar transmitter (TX) using the envelope-tracking (ET) technique for mobile WiMAX applications. Monolithic power amplifiers (PAs) are designed and fabricated in IBM 0.18 μm SiGe BiCMOS technology, and a linear-assisted switch-mode envelope amplifier is applied to modulate the PA supply voltage to form the core of the RF polar TX. Nonlinearities caused by bandwidth limitation of the envelope amplifier and timing misalignment have been investigated. When driven by WiMAX 64QAM 8.75 MHz signals, the overall PAE of our ET-based polar TX system reaches 30.5% at 17 dBm average output power, while also meeting the stringent WiMAX linearity specs without using any predistortion. When the decresting algorithm using the soft limiter is applied to the baseband, the overall PAE increases to 33%, at the expense of a higher EVM of 4.9%. Based on measurement results, our ET-based polar TX system has demonstrated excellent efficiency with good linearity for high peak-to-average ratio (PAR) broadband signals when compared with the recent literature on state-of-the-arts polar TX designs.
2 June 2021 in IEEE Microwave and Wireless Components Letters
A medium-power, highly-efficient broadband linear power amplifier (PA) is designed in a 40-nm GaN technology that covers the key 5G FR2 band of 24-40 GHz. Load-pull simulations suggest better device broadband performance and peak power-added-efficiency (PAE) around V DD = 4-6 V. Measurement data corroborates the simulations and this PA achieves a small-signal 3-dB bandwidth (BW) of 18.0-40.3 GHz, with max. PAE/P SAT of 42.1%/18.6 dBm at 28 GHz, and 26.0%/17.2 dBm at 38 GHz at V DD = 4 V. When tested with a 9 MHz × 100 MHz 256-quadratic-amplitude modulation (QAM) 5G new radio (NR) signal, it achieves an adjacent-channel-leakage-ratio (ACLR) of -27 dBc with P OUT, AVG /PAE of 11.3 dBm/13.9% at 28 GHz. When compared with state-of-the-art broadband PAs, it achieves the best S 21 3-dB BW with excellent peak PAE and linearity. This work also reports the best PAE for broadband medium-power millimeter-wave GaN PA at P SAT ~ 20 dBm.
Gait analysis using wearable wireless sensors can be an economical, convenient and effective way to provide diagnostic and clinical information for various health-related issues. In this work, our custom designed low-cost wireless gait analysis sensor that contains a basic inertial measurement unit (IMU) was used to collect the gait data for four patients diagnosed with balance disorders and additionally three normal subjects, each performing the Dynamic Gait Index (DGI) tests while wearing the custom wireless gait analysis sensor (WGAS). The small WGAS includes a tri-axial accelerometer integrated circuit (IC), two gyroscopes ICs and a Texas Instruments (TI) MSP430 microcontroller and is worn by each subject at the T4 position during the DGI tests. The raw gait data are wirelessly transmitted from the WGAS to a near-by PC for real-time gait data collection and analysis. In order to perform successful classification of patients vs. normal subjects, we used several different classification algorithms, such as the back propagation artificial neural network (BP-ANN), support vector machine (SVM), k-nearest neighbors (KNN) and binary decision trees (BDT), based on features extracted from the raw gait data of the gyroscopes and accelerometers. When the range was used as the input feature, the overall classification accuracy obtained is 100% with BP-ANN, 98% with SVM, 96% with KNN and 94% using BDT. Similar high classification accuracy results were also achieved when the standard deviation or other values were used as input features to these classifiers. These results show that gait data collected from our very low-cost wearable wireless gait sensor can effectively differentiate patients with balance disorders from normal subjects in real time using various classifiers, the success of which may eventually lead to accurate and objective diagnosis of abnormal human gaits and their underlying etiologies in the future, as more patient data are being collected.
Metastable pseudomorphic Ge0.12Si0.88 films were grown by molecular beam epitaxy on Si(100) substrates and then implanted with 100 keV 31P at room temperature for a dose of 5×1013/cm2. Samples were subsequently annealed by rapid thermal annealing (RTA) in nitrogen and by steady‐state furnace annealing in vacuum. Both damage and strain introduced by implantation can be completely removed, within instrumental sensitivity, by RTA at 700 °C for 10–40 s. Vacuum annealing for 30 min at 500–550 °C removes most of the damage and strain induced by the implantation but the activation of the P is poor. At 700 °C, the activation is nearly 100%, but the crystallinity worsens and the pseudomorphic strain begins to relax. We conclude that for a lightly implanted metastable and pseudomorphic GeSi epilayer on Si, steady‐state vacuum annealing cannot achieve good dopant activation without introducing significant strain relaxation to the heterostructure, while RTA can.