For the functional control of prosthetic hand, it is insufficient to obtain only the motion pattern information. As far as practicality is concerned, the control of the prosthetic hand force is indispensable. The application value of prosthetic hand will be greatly improved if the stable grip of prosthetic hand can be achieved. To address this problem, in this study, a bio-signal control method for grasping control of a prosthetic hand is proposed to improve patient’s sense of using prosthetic hand and the thus improving the quality of life. A MYO gesture control armband is used to collect the surface electromyographic (sEMG) signals from the upper limb. The overlapping sliding window scheme are applied for data segmentation and the correlated features are extracted from each segmented data. Principal component analysis (PCA) methods are then deployed for dimension reduction. Deep neural network is used to generate sEMG-force regression model for force prediction at different levels. The predicted force values are input to a fuzzy controller for the grasping control of a prosthetic hand. A vibration feedback device is used to feed grasping force value back to patient’s arm to improve patient’s sense of using prosthetic hand and realize accurate grasping. To test the effectiveness of the scheme, 15 able-bodied subjects participated in the experiments. The classification results indicated that 8-channel sEMG applying all four time-domain features, with PCA reduction from 32 to 8 dimensions results in the highest classification accuracy. Based on the experimental results from 15 participants, the average recognition rate is over 95%. On the other hand, from the statistical results of standard deviation, the between-subject variations ranges from 3.58 to 1.25%, proving that the robustness and stability of the proposed approach. The method proposed hereto control grasping power through the patient’s own sEMG signal, which achieves a high recognition rate to improve the success rate of grip and increases the sense of operation and also brings the gospel for upper extremity amputation patients.
As the restaurant industry is facing labor shortage issues, the use of meal delivery robots instead of waiters/waitresses not only allows the customers to experience the impact of robot technology but also benefits the restaurant business financially by reducing labor costs. Most existing meal delivery robots employ magnetic navigation technologies, which require magnetic strip installation and changes to the restaurant decor. Once the moving path is changed, the magnetic strips need to be re-laid. This study proposes multisource information fusion, i.e., the fusion of ultra-wide band positioning technology with an odometer and a low-cost gyroscope accelerometer, to achieve the positioning of a non-rail meal delivery robot with navigation. By using a low-cost electronic compass and gyroscope accelerometer, the delivery robot can move along a fixed orbit in a flexible and cost-effective manner with steering control. Ultra-wide band (UWB) and track estimation algorithm are combined by extended Kalman filter (EKF), and the positioning error after fusion is about 15 cm, which is accepted by restaurants. In summary, the proposed approach has some potential for commercial applications.
9 September 2024 in International Journal of Adaptive Control and Signal Processing
Male infertility is a global health issue, with 40–50% attributed to sperm abnormalities. The subjectivity and irreproducibility of existing detection methods pose challenges to sperm assessment, making the design of automated semen analysis algorithms crucial for enhancing the reliability of sperm evaluations. This paper proposes a comprehensive sperm tracking algorithm (Sperm YOLOv8E-TrackEVD) that combines an enhanced YOLOv8 small object detection algorithm (SpermYOLOv8-E) with an improved DeepOCSORT tracking algorithm (SpermTrack-EVD) to detect human sperm in a microscopic field of view and track healthy sperm in a sample in a short period effectively. Firstly, we trained the improved YOLOv8 model on the VISEM-Tracking dataset for accurate sperm detection. To enhance the detection of small sperm objects, we introduced an attention mechanism, added a small object detection layer, and integrated the SPDConv and Detect_DyHead modules. Furthermore, we used a new distance metric method and chose IoU loss calculation. Ultimately, we achieved a 1.3% increase in precision, a 1.4% increase in recall rate, and a 2.0% improvement in mAP@0.5:0.95. We applied SpermYOLOv8-E combined with SpermTrack-EVD for sperm tracking. On the VISEM-Tracking dataset, we achieved 74.303% HOTA and 71.167% MOTA. These results show the effectiveness of the designed Sperm YOLOv8E-TrackEVD approach in sperm tracking scenarios.
For a SLAM system operating in a dynamic indoor environment, its position estimation accuracy and visual odometer stability could be reduced because the system can be easily affected by moving obstacles. In this paper, a visual SLAM algorithm based on the Yolov4-Tiny network is proposed. Meanwhile, a dynamic feature point elimination strategy based on the traditional ORBSLAM is proposed. Besides this, to obtain semantic information, object detection is carried out when the feature points of the image are extracted. In addition, the epipolar geometry algorithm and the LK optical flow method are employed to detect dynamic objects. The dynamic feature points are removed in the tracking thread, and only the static feature points are used to estimate the position of the camera. The proposed method is evaluated on the TUM dataset. The experimental results show that, compared with ORB-SLAM2, our algorithm improves the camera position estimation accuracy by 93.35% in a highly dynamic environment. Additionally, the average time needed by our algorithm to process an image frame in the tracking thread is 21.49 ms, achieving real-time performance.
For the successful application of brain-computer interface (BCI) systems, accurate recognition of electroencephalography (EEG) signals is one of the core issues. To solve the differences in individual EEG signals and the problem of less EEG data in classification and recognition, an attention mechanism-based multi-scale convolution network was designed; the transfer learning data alignment algorithm was then introduced to explore the application of transfer learning for analyzing motor imagery EEG signals. The data set 2a of BCI Competition IV was used to verify the designed dual channel attention module migration alignment with convolution neural network (MS-AFM). Experimental results showed that the classification recognition rate improved with the addition of the alignment algorithm and adaptive adjustment in transfer learning; the average classification recognition rate of nine subjects was 86.03%.