When a multi-inverter grid-connected system is influenced by the parasitic parameters of LCL-type inverters and the impedance of the connected system’s lines, its resonance characteristics become more complex and difficult to predict. For LCL-type multi-inverter grid-connected systems, a mathematical model that considers the effects of parasitic parameters and line impedance has been established, leading to the derivation of the system’s Norton equivalent circuit and a general expression for the inverter output current. The resonance characteristics of multi-inverter grid-connected systems composed of inverters with the same and different parameters were analyzed under the influence of parasitic parameters and line impedance. To suppress the resonance in multi-inverter grid-connected systems and address the issue of traditional PI control not meeting grid requirements for LCL-type grid-connected inverters, a strategy combining superhelical sliding mode control with active damping was adopted. To verify the practical performance of the adopted resonance suppression strategy in complex environments, a grid-connected system model containing two LCL-type inverters was constructed using the MATLAB/Simulink software platform, followed by simulation analysis. The simulation results strongly confirm the feasibility and effectiveness of the adopted resonance suppression strategy, considering the effects of parasitic parameters and line impedance. This strategy demonstrates significant suppression effects in addressing resonance issues caused by parasitic parameters and line impedance, effectively enhancing the quality of grid-connected electrical energy.
The current inverter control strategies have limitations in suppressing grid resonance, especially in complex grid environments with high penetration of renewable energy sources. These strate-gies often focus on suppressing resonance at a single frequency point, but their effectiveness is constrained when dealing with multi-band resonance or dynamically changing grid conditions. The study investigates the application of parallel-operated inverters in the grid, particularly their impact on grid stability. A novel active damping strategy is developed to enhance the grid’s dynamic response and suppress grid resonance. The effectiveness of the control strategy is verified through simulation by establishing Norton equivalent circuit models for multiple in-verters. Fast Through simulation, this study comprehensively evaluates the performance and adaptability of the strategy under various conditions. Results demonstrate that implementing the active damping strategy increases the inverter output power from 9.5 kW to 10 kW, an im-provement of 5.26%. System response time is reduced from 50 ms to 30 ms, and post-stabilization fluctuations decrease to 1.5%. These data conclusively prove the effectiveness of the control strategy in enhancing grid stability and reducing resonance effects. The findings underscore the potential of active damping strategies in improving grid performance and in-verter efficiency. However, further research and optimization are necessary to assess the adapt-ability of these strategies under different grid conditions.
The continual switching activity of the switching converter generates electromagnetic interference (EMI) within the system. Single-stage active EMI filters (AEFs) are ineffective at suppressing EMI, whereas multistage active filters are cumbersome and intricately designed. This paper proposes a multi-current injection active EMI filter (MCI-AEF) that incorporates feed-forward and feed-back techniques to address these issues. The results indicate that this filter suppresses EMI more effectively than a single-stage filter of comparable dimensions.