Sonja K. Schickhardt

Dr. Sonja K. Schickhardt


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 February 2021 in Ophthalmology and Therapy
Verified
Journal Article
Open access
PDF file
QWQiang Wang
Qiang Wang
TYTimur M. Yildirim
Timur M. Yildirim
SSSonja K. Schickhardt
Sonja K. Schickhardt
GŁGrzegorz Łabuz
Grzegorz Łabuz
Ramin KhoramniaRamin Khoramnia
Ramin Khoramnia
GAGerd U. Auffarth
Gerd U. Auffarth
Introduction Foldable hydrophobic acrylic intraocular lenses (IOLs) are prone to develop a long-term postoperative material change called glistenings. The aim of this study was to investigate the changes in the predisposition for glistening formation in one type of hydrophobic acrylic IOL material from its introduction to the present day. Methods In a laboratory setup, an in vitro model was used to induce glistenings in hydrophobic acrylic IOLs manufactured by one company (Alcon, Fort Worth, TX, USA) in different years: 23 1990s-manufacture hydrophobic acrylic three-piece IOLs (MA30BA/MA60AC) that were explanted in 1996 and 1997, and five of each of the newer AcrySof IOL models (MA60AC, SA60AT, TFNT00 and SN60WF) from 2014 to 2017. Furthermore, five Clareon (SY60WF) IOLs were put through the same accelerated aging procedure. The number of microvacuoles per square millimeter (MV/mm2) was determined in the central part of each IOL optic and compared between the groups. Results The mean number of MV was highest in the 1990s-manufacture Alcon acrylic IOLs, with 1289 (± 738) MV/mm2. The number decreased to 650 (± 101), 192 (± 105), 175 (± 112) and 47 (± 26) for MA60AC, SA60AT, TFNT00 and SN60WF, respectively. The lowest count was obtained in the Clareon group, with 1 (± 1) MV/mm2. Conclusions A high number of glistenings was induced in the explanted IOLs from the 1990s. The propensity for glistening formation decreased considerably after that decade and now in current use. Even though in vitro glistening formation in today’s AcrySof material was low, the Clareon material was essentially glistenings-free.

28 June 2022 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
MHMaximilian Hammer
Maximilian Hammer
SSSonja K. Schickhardt
Sonja K. Schickhardt
PMPatrick Roman Merz
Patrick Roman Merz
Ramin KhoramniaRamin Khoramnia
Ramin Khoramnia
ASAlexander F. Scheuerle
Alexander F. Scheuerle
GAGerd U. Auffarth
Gerd U. Auffarth
Silicone oil endotamponades provide a reservoir for drugs in the eye. Following vitrectomy surgery to treat retinal detachments, extensive diabetic retinopathy or endophthalmitis, they can be used as long-term lipophilic depots. This study aimed to investigate the physicochemical properties of intravitreally applied drugs of different lipophilicity, namely vancomycin, ceftazidime and voriconazole. For this purpose, an in vitro model of the silicone-oil-filled eye compared to porcine vitreous bodies (PVBs) was used. In a glass container, either light or heavy silicone oil or PVB was set into equilibrium with an aqueous fluid. Vancomycin, voriconazole and ceftazidime were added in concentrations commonly applied in clinical practice. The time course of the concentration of the drugs was determined in the hydrophilic phase for up to 24 h. With silicone oil present, the concentrations of vancomycin, voriconazole and ceftazidime were elevated in the aqueous humor when compared to the vitreous body (p < 0.001 for all drugs). With increasing lipophilicity, higher concentrations of the drug dissolved in silicone oil after 24 h (52.7%, 49.1% and 34.3% for vancomycin, ceftazidime and voriconazole, respectively). While no difference between lighter- and heavier-than-water silicone oil was apparent for vancomycin and ceftazidime (p = 0.17 and p = 0.72), voriconazole dissolved significantly better in the heavier-than-water silicone oil (p = 0.002). A higher-than-expected percentage of the glycopeptide vancomycin dissolved in the porcine vitreous body, possibly due to protein binding. In conclusion, silicone oils influence the drug concentration and distribution of intravitreally applied drugs depending on their lipophilicity. The addition of F6H8 used to create heavy silicone oils attenuates these effects for lipophilic drugs. Knowledge of the distribution of these intravitreally applied drugs is crucial to ensure the desired anti-infectious effect.

1 September 2020 in American Journal of Ophthalmology Case Reports
Verified
Journal Article
Open access
TYTimur M. Yildirim
Timur M. Yildirim
Ramin KhoramniaRamin Khoramnia
Ramin Khoramnia
SSSonja K. Schickhardt
Sonja K. Schickhardt
DMDonald J. Munro
Donald J. Munro
PMPatrick Roman Merz
Patrick Roman Merz
GAGerd U. Auffarth
Gerd U. Auffarth
Analysis of explanted intraocular lenses (IOLs) from pseudophakic eyes with supplementary sulcus-supported IOLs. In this laboratory investigation, ten supplementary and capsular bag IOLs were analyzed. All lenses were received between January 2012 and March 2018. Explants were examined morphologically with histological and electron microscopic techniques and patients’ medical history was evaluated. Additionally, we used a technique new to this field: Transmission Electron Microscopy and electron diffraction pattern analysis was performed to investigate the structure of the opacifying crystals in detail. Eleven lenses were explanted due to IOL opacification from seven polypseudophakic eyes: In three cases the supplementary lens calcified, in three cases the capsular bag IOL (both lenses analyzed) and in one case both IOLs (only the supplementary was received). Additional surgical procedures and comorbidities included pars plana vitrectomy or Descemet stripping endothelial keratoplasty and diabetes mellitus. For each opacified lens, a varying layer of a Calcium phosphate beneath the optic surface was apparent. Crystal characterization revealed its composition to be Hydroxyapatite. We report on a series of secondary calcification in lenses explanted from polypseudophakic eyes. In some cases, calcification occurred in the capsular bag lens, in other cases in the supplementary lens, or in both. The severity of the morphological change could be related to the comorbidities and the presence of surgery subsequent to the lens implantations. Detailed morphology of the opacifying crystals was revealed.

28 June 2021 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Open access
LZLu Zhang
Lu Zhang
SSSonja K. Schickhardt
Sonja K. Schickhardt
HFHui Fang
Hui Fang
FAFlorian Auerbach
Florian Auerbach
PCPerfecto Iii Cagampang
Perfecto Iii Cagampang
GAGerd U. Auffarth
Gerd U. Auffarth
Purpose: To compare 1 new intraocular lens injector system against 3 standard injector systems in porcine eyes. Setting: David J Apple Center for Vision Research, Department of Ophthalmology, University Hospital Heidelberg, Heidelberg, Germany. Design: In vitro laboratory study. Methods: In 70 porcine eyes, +20.0 diopter IOLs were implanted with the following systems: multiSert, UltraSert, iTec and RayOne, i.e., S1.8 (incision size: 1.8mm), S2.0 (2.0mm), S2.2P (2.2mm, push-mode), S2.2S (2.2mm, screw-mode), U2.2 (2.2mm), iT2.2 (2.2mm) and R2.0 (2.0mm). Corneal incision sizes were measured before and after implantation with a incision gauge set. Ease of use was evaluated using a Likert scale. IOL delivery time and performance were determined based on Miyake-Apple view videos. Results: The incision enlargements were 0.36 ± 0.08mm (S1.8), 0.15 ± 0.07mm (S2.0), 0.17 ± 0.12mm (S2.2P), 0.28 ± 0.10mm (S2.2S), 0.32 ± 0.09mm (U2.2), 0.30 ± 0.08mm (iT2.2) and 0.35 ± 0.11mm (R2.0). Total scores of ease of use were 23.00 (S1.8), 25.00 (S2.0), 29.00 (S2.2P), 26.00 (S2.2S), 26.00 (U2.2), 25.00 (iT2.2) and 24.00 (R2.0). As for the mean delivery time, iT2.2 took the longest time (13.20 ± 3.29 seconds), while S2.2S took the shortest time (4.50 ± 0.71 seconds). Haptic-optic adhesion was observed in S1.8 (4, 40%), S2.2P (2, 20%), U2.2 (5, 50%) and iT2.2 (5, 50%). Conclusions: Injector S, with the appropriate incision size and implantation method, could achieve better results regarding incision enlargement, ease of use, delivery time and performance than other injector systems. There was an indirect relationship between incision size and inadvertent events.

21 October 2023 in Gels
Verified
Journal Article
Open access
PDF file
MHMaximilian Hammer
Maximilian Hammer
JHJonathan Herth
Jonathan Herth
MMMarcel Muuss
Marcel Muuss
SSSonja K. Schickhardt
Sonja K. Schickhardt
ASAlexander Scheuerle
Alexander Scheuerle
GAGerd U. Auffarth
Gerd U. Auffarth
To treat certain vitreoretinal diseases, the vitreous body, a hydrogel composed of mostly collagen and hyaluronic acid, must be removed. After vitrectomy surgery, the vitreous cavity is filled with an endotamponade. Previously, pre-clinical hydrogel-based vitreous body substitutes either made from uncrosslinked monomers (1st generation), preformed crosslinked polymers (2nd generation), or in situ gelating polymers (3rd generation) have been developed. Forward light scattering is a measure of Stray light induced by optical media, when increased, causing visual disturbance and glare. During pinhole surgery, the hydrogels are injected into the vitreous cavity through a small 23G-cannula. The aim of this study was to assess if and to what extent forward light scattering is induced by vitreous body replacement hydrogels and if Stray light differs between different generations of vitreous body hydrogel replacements due to the different gelation mechanisms and fragmentation during injection. A modified C-Quant setup was used to objectively determine forward light scattering. In this study, we found that the 1st and 3rd generation vitreous body replacements show very low stray light levels even after injection (2.8 +/− 0.4 deg2/sr and 0.2 +/− 0.2 deg2/sr, respectively) as gel fragmentation and generation of interfaces is circumvented. The 2nd generation preformed hydrogels showed a permanent increase in stray light after injection that will most likely lead to symptoms such as glare when used in patients (11.9 +/− 0.9 deg2/sr). Stray light of the 2nd generation hydrogels was 3- and 2-fold increased compared to juvenile and aged vitreous bodies, respectively. In conclusion, this significant downside in the forward light scattering of the 2nd generation hydrogels should be kept in mind when developing vitreous body replacement strategies, as any source of stray light should be minimized in patients with retinal comorbidities.

1 June 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
SBSilvia Bopp
Silvia Bopp
HOHuseyin Baran Ozdemir
Huseyin Baran Ozdemir
ZAZeynep Aktaş
Zeynep Aktaş
Ramin KhoramniaRamin Khoramnia
Ramin Khoramnia
TYTimur M. Yildirim
Timur M. Yildirim
ŞÖŞengül Özdek
Şengül Özdek
Aim: To determine the clinical risk factors that may increase the occurrence of intraocular lens (IOL) calcification in patients who had undergone pars plana vitrectomy (PPV). Methods: The medical records of 14 patients who underwent IOL explantation due to clinically significant IOL opacification after PPV were reviewed. The date of primary cataract surgery, technique and implanted IOL characteristics; the time, cause and technique of PPV; tamponade used; additional surgeries; the time of IOL calcification and explantation; and IOL explantation technique were investigated. Results: PPV had been performed as a combined procedure with cataract surgery in eight eyes and solely in six pseudophakic eyes. The IOL material was hydrophilic in six eyes, hydrophilic with a hydrophobic surface in seven eyes and undetermined in one eye. The endotamponades used during primary PPV were C2F6 in eight eyes, C3F8 in one eye, air in two eyes and silicone oil in three eyes. Two of three eyes underwent subsequent silicone oil removal and gas tamponade exchange. Gas in the anterior chamber was detected in six eyes after PPV or silicone oil removal. The mean interval between PPV and IOL opacification was 20.5 ± 18.6 months. The mean BCVA in logMAR was 0.43 ± 0.42 after PPV, which significantly decreased to 0.67 ± 0.68 before IOL explantation for IOL opacification (p = 0.007) and increased to 0.48 ± 0.59 after the IOL exchange (p = 0.015). Conclusions: PPV with endotamponades in pseudophakic eyes, particularly gas, seems to increase the risk for secondary IOL calcification, especially in hydrophilic IOLs. IOL exchange seems to solve this problem when clinically significant vision loss occurs.