Sang-Ha Oh

Sang-Ha Oh


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 September 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
BSBokeun Song
Bokeun Song
JKJeonghee Kim
Jeonghee Kim
HKHyeokjae Kwon
Hyeokjae Kwon
SKSun Je Kim
Sun Je Kim
SOSang-Ha Oh
Sang-Ha Oh
SSSeung Han Song
Seung Han Song
The accurate assessment of wound size is a critical step in advanced wound care management. This study aims to introduce and validate a Light Detection and Ranging (LiDAR) technique for measuring wound size. Twenty-eight wounds treated from December 2022 to April 2023 at the Chungnam National University Hospital were analyzed. All the wounds were measured using three techniques: conventional ruler methods, the LiDAR technique, and ImageJ analysis. Correlation analysis, linear regression, and Bland–Altman plot analysis were performed to validate the accuracy of the novel method. The measurement results (mean ± standard deviation) obtained using the ruler method, LiDAR technique, and ImageJ analysis were 112.99 ± 110.07 cm2, 73.59 ± 72.97 cm2, and 74.29 ± 72.15 cm2, respectively. The Pearson correlation coefficient was higher for the LiDAR application (0.995) than for the conventional ruler methods (mean difference, −5.0000 cm2), as was the degree of agreement (mean difference, 38.6933 cm2). Wound size measurement using LiDAR is a simple and reliable method that will enable practitioners to conveniently assess wounds with a flattened and irregular shape with higher accuracy. However, non-flattened wounds cannot be assessed owing to the technical limitations of LiDAR.

1 December 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
BSBokeun Song
Bokeun Song
HKHyeokjae Kwon
Hyeokjae Kwon
SKSun Je Kim
Sun Je Kim
YHYooseok Ha
Yooseok Ha
SOSang-Ha Oh
Sang-Ha Oh
SSSeung Han Song
Seung Han Song
Marginal reflex distance1 (MRD1) is a crucial clinical tool used to evaluate the position of the eyelid margin in relation to the cornea. Traditionally, this assessment has been conducted manually by plastic surgeons, ophthalmologists, or trained technicians. However, with the advancements in artificial intelligence (AI) technology, there is a growing interest in the development of automated systems capable of accurately measuring MRD1. In this context, we introduce novel MRD1 measurement methods based on deep learning algorithms that can simultaneously capture images and compute the results. This prospective observational study involved 154 eyes of 77 patients aged over 18 years who visited Chungnam National University Hospital between 1 January 2023 and 29 July 2023. We collected four different MRD1 datasets from patients using three distinct measurement methods, each tailored to the individual patient. The mean MRD1 values, measured through the manual method using a penlight, the deep learning method, ImageJ analysis from RGB eye images, and ImageJ analysis from IR eye images in 56 eyes of 28 patients, were 2.64 ± 1.04 mm, 2.85 ± 1.07 mm, 2.78 ± 1.08 mm, and 3.07 ± 0.95 mm, respectively. Notably, the strongest agreement was observed between MRD1_deep learning (DL) and MRD1_IR (0.822, p < 0.01). In a Bland–Altman plot, the smallest difference was observed between MRD1_DL and MRD1_IR ImageJ, with a mean difference of 0.0611 and ΔLOA (limits of agreement) of 2.5162, which was the smallest among all of the groups. In conclusion, this novel MRD1 measurement method, based on an IR camera and deep learning, demonstrates statistical significance and can be readily applied in clinical settings.

28 November 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
BSBokeun Song
Bokeun Song
HKHyeokjae Kwon
Hyeokjae Kwon
SKSun Je Kim
Sun Je Kim
YHYooseok Ha
Yooseok Ha
SOSang-Ha Oh
Sang-Ha Oh
SSSeung Han Song
Seung Han Song
Measuring Marginal Reflex Distance-1 (MRD-1) is a crucial clinical tool used to evaluate the position of the eyelid margin in relation to the cornea. Traditionally, this assessment has been conducted manually by plastic surgeons, ophthalmologists, or trained technicians. However, with the advancements in Artificial Intelligence (AI) technology, there is a growing interest in the development of automated systems capable of accurately measuring MRD-1.In this context, we introduce novel MRD-1 measurement methods based on deep learning algorithms that can simultaneously capture images and compute the results. This prospective observational study involved 154 eyes of 77 patients aged over 18 years who visited Chungnam National University Hospital between September 1, 2023, and July 29, 2023. We collected four different MRD1 da-tasets from patients using three distinct measurement methods, each tailored to the individual patient. The mean MRD1 values, measured through the manual method using a penlight, the deep learning method, ImageJ analysis from RGB eye images, and ImageJ analysis from IR eye images in 56 eyes of 28 patients, were 2.64 ± 1.04 mm, 2.85 ± 1.07 mm, 2.78 ± 1.08 mm, and 3.07 ± 0.95 mm, respectively. Notably, the strongest agreement was observed between MRD1_deep learning (DL) and MRD1_IR (0.822, p < 0.01). In the Bland-Altman plot, the smallest difference was observed between MRD1_DL and MRD1_IR ImageJ, with a mean difference of 0.0611 and △LOA (limits of agreement) of 2.5162, which is the smallest among the other groups. In conclusion, this novel MRD1 measurement method, based on an IR camera and deep learning, demon-strates statistical significance and can be readily applied in clinical settings.

15 September 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
BSBokeun Song
Bokeun Song
JKJeonghee Kim
Jeonghee Kim
HKHyeokjae Kwon
Hyeokjae Kwon
SKSun Je Kim
Sun Je Kim
SOSang-Ha Oh
Sang-Ha Oh
SSSeung Han Song
Seung Han Song
The accurate assessment of wound size is a critical step in advanced wound care management. This study aims to introduce and validate a Light Detection and Ranging (LiDAR) technique for measuring wound size. Twenty-eight wounds treated from December 2022 to April 2023 at the Chunganam National University Hospital were analyzed. All wounds were measured using three techniques; conventional ruler methods, the LiDAR technique, and ImageJ analysis. Correlation analysis, linear regression, and Bland-Altman plot analysis were conducted to validate the accuracy of the newly introduced method. The measurement results (Mean ± Standard deviation) obtained using the Ruler method, LiDAR technique, and ImageJ analysis were 112.99 ± 110.07 cm², 73.59 ± 72.97 cm², and 74.29 ± 72.15 cm², respectively. The Pearson correlation coefficient was higher in the LiDAR application (0.995) than the conventional ruler methods (Mean difference; -5.0000 cm2), as was the degree of agreement (Mean difference; 38.6933 cm2). Wound size measurement using LiDAR is a simple and reliable method that allows practitioners to conveniently assess wounds with a flattened and irregular shape. However, non-flattened wounds cannot be assessed owing to the technical limitations of LiDAR.