Long-range power-law correlations have been reported recently for DNA sequences containing noncoding regions. We address the question of whether such correlations may be a trivial consequence of the known mosaic structure (‘‘patchiness’’) of DNA. We analyze two classes of controls consisting of patchy nucleotide sequences generated by different algorithms—one without and one with long-range power-law correlations. Although both types of sequences are highly heterogeneous, they are quantitatively distinguishable by new fluctuation analysis method that differentiates local patchiness from long-range correlations. Application of this analysis to selected DNA sequences demonstrates that patchiness is not sufficient to account for long-range correlation properties.
1 March 1995 in Chaos: An Interdisciplinary Journal of Nonlinear Science
The healthy heartbeat is traditionally thought to be regulated according to the classical principle of homeostasis whereby physiologic systems operate to reduce variability and achieve an equilibrium-like state [Physiol. Rev. 9, 399–431 (1929)]. However, recent studies [Phys. Rev. Lett. 70, 1343–1346 (1993); Fractals in Biology and Medicine (Birkhauser-Verlag, Basel, 1994), pp. 55–65] reveal that under normal conditions, beat-to-beat fluctuations in heart rate display the kind of long-range correlations typically exhibited by dynamical systems far from equilibrium [Phys. Rev. Lett. 59, 381–384 (1987)]. In contrast, heart rate time series from patients with severe congestive heart failure show a breakdown of this long-range correlation behavior. We describe a new method—detrended fluctuation analysis (DFA)—for quantifying this correlation property in non-stationary physiological time series. Application of this technique shows evidence for a crossover phenomenon associated with a change in short and long-range scaling exponents. This method may be of use in distinguishing healthy from pathologic data sets based on differences in these scaling properties.
There has been considerable interest in quantifying the complexity of physiologic time series, such as heart rate. However, traditional algorithms indicate higher complexity for certain pathologic processes associated with random outputs than for healthy dynamics exhibiting long-range correlations. This paradox may be due to the fact that conventional algorithms fail to account for the multiple time scales inherent in healthy physiologic dynamics. We introduce a method to calculate multiscale entropy (MSE) for complex time series. We find that MSE robustly separates healthy and pathologic groups and consistently yields higher values for simulated long-range correlated noise compared to uncorrelated noise.
Traditional approaches to measuring the complexity of biological signals fail to account for the multiple time scales inherent in such time series. These algorithms have yielded contradictory findings when applied to real-world datasets obtained in health and disease states. We describe in detail the basis and implementation of the multiscale entropy (MSE) method. We extend and elaborate previous findings showing its applicability to the fluctuations of the human heartbeat under physiologic and pathologic conditions. The method consistently indicates a loss of complexity with aging, with an erratic cardiac arrhythmia (atrial fibrillation), and with a life-threatening syndrome (congestive heart failure). Further, these different conditions have distinct MSE curve profiles, suggesting diagnostic uses. The results support a general "complexity-loss" theory of aging and disease. We also apply the method to the analysis of coding and noncoding DNA sequences and find that the latter have higher multiscale entropy, consistent with the emerging view that so-called "junk DNA" sequences contain important biological information.
19 February 2002 in Proceedings of the National Academy of Sciences
According to classical concepts of physiologic control, healthy systems are self-regulated to reduce variability and maintain physiologic constancy. Contrary to the predictions of homeostasis, however, the output of a wide variety of systems, such as the normal human heartbeat, fluctuates in a complex manner, even under resting conditions. Scaling techniques adapted from statistical physics reveal the presence of long-range, power-law correlations, as part of multifractal cascades operating over a wide range of time scales. These scaling properties suggest that the nonlinear regulatory systems are operating far from equilibrium, and that maintaining constancy is not the goal of physiologic control. In contrast, for subjects at high risk of sudden death (including those with heart failure), fractal organization, along with certain nonlinear interactions, breaks down. Application of fractal analysis may provide new approaches to assessing cardiac risk and forecasting sudden cardiac death, as well as to monitoring the aging process. Similar approaches show promise in assessing other regulatory systems, such as human gait control in health and disease. Elucidating the fractal and nonlinear mechanisms involved in physiologic control and complex signaling networks is emerging as a major challenge in the postgenomic era.