The FY-4B satellite is one of the second generation of China’s geosynchronous meteorological satellites aiming at numerical weather forecasts. The space environment monitoring package (SEMP) onboard the FY-4B is a comprehensive instrument package for plasma, high-energy particle, and energetic neutral particle measurements. The low-energy particle analyzer (LEPA) is one of the instruments of the SEMP and consists of two top hat electrostatic analyzers designed for plasma detection. The electron and ion sensors are back-to-back assembled and are integrated to a shared electronic box. It measures the three-dimensional velocity distribution of low-energy electrons and ions on the geosynchronous orbit. In this paper, we present the ground calibration and in-flight performance of the instrument. With the electrostatic deflectors and the cylindrically symmetric structure, the instrument provides high-cadence measurements of electron and ion velocity distributions with a wide field of view (FOV) of 180° by 100°, an angular resolution of 16.7° × 20°, and a broad energy range for both the electrons and ions from tens of eV to above 30 keV, with a 1 s time resolution. The geometric factors of the electron and ion analyzers are 1.1 × 10−3 cm2·sr·eV/eV and 1.4 × 10−3 cm2·sr·eV/eV, respectively, which fulfills the requirements of the low-energy plasma measurement. The LEPA monitored typical space environment disturbance such as geomagnetic storms and successfully recorded the responses of plasma energy fluxes. Satellite surface charging events were measured, with the highest potentials of −2000 V in the shadow period and −500 V in the nonshadow period.
In this paper, we propose a bipolar charge plasma spectrometer based on the double-channel electrostatic analyzer for simultaneously measuring thermal ions and electrons with a 2π hemispherical field-of-view. Both ions and electrons within the wide field-of-view enter the spectrometer, pass through the variable geometric factor channel, and are then separated by the double-channel electric fields. Two microchannel plates are accommodated at the exit of the analyzer for ion and electron detection. The main performance of the spectrometer has been obtained from on-ground calibration. With the electrostatic deflectors and the cylindrically symmetric structure, the spectrometer provides simultaneous measurements of thermal ion and electron velocity distributions with a shared field-of-view of 360° (azimuth angle) by 90° (elevation angle) and a broad energy range for both ions and electrons. The ion analyzer constant and the electron analyzer constant are 11.1 and 9.7, respectively. The detecting energy range of 33.3–44.4 keV for ions and 29.1–38.8 keV for electrons can be obtained by using the sweeping electrostatic analyzer voltage range of 3–4000 V. The ion and electron energy resolutions are 9.6% and 6.1%, respectively. The variable geometric factor function provides a large geometric factor adjusting range for both ion and electron measurements by two orders of magnitude, which fulfills the requirements of a large dynamic flux range for simultaneous measurements of space thermal plasma in the solar wind and magnetosphere.
The plasma analyzer (PMA) on the Fengyun-3E (FY-3E) meteorological satellite series is a critical sensor of the space environment monitoring package that is capable of the comprehensive in situ detection of the thermal plasma environment and surface discharge effects. In this paper, we conducted a thorough evaluation of the PMA’s performance and reliability through a combination of ground-based laboratory calibration and in-orbit testing. During the ground-based calibration, the PMA underwent assessments for the energy range, field of view (FOV), and measurement accuracy, and obtained the detection accuracy and the geometric factors. During the in-orbit testing, the PMA successfully obtained the typical distribution characteristics of low-energy ions and electrons in orbital space regions, as well as the precipitating particles in the middle and high latitudes of both hemispheres. Notably, the PMA observed an expansion of the particle distribution in the high-latitude regions during a moderate geomagnetic storm. The results from both the ground-based calibration and in-orbit testing demonstrated that the PMA met the requirements for thermal plasma detection, with reliable and scientifically valid in-orbit detection data. These results provide a crucial foundation for studying spatial weather variations, improving the accuracy of space environment forecasts and enhancing disaster detection and monitoring capabilities.
1 February 2021 in Review of Scientific Instruments
Space plasma instruments provide 3D particle velocity distribution functions. Because of telemetry limitations, these cannot be transmitted in high time resolution and the plasma needs to be characterized by moments of the velocity distribution function. These moment uncertainties have vital effects on the reliability and accuracy of onboard plasma moments. We assess the measurement accuracy for magnetosheath and solar wind ions using an ion spectrometer with an asymmetric field of view designed for the all-sky measurement of low-energy ions in the magnetosheath and solar wind. We focus on moment uncertainties for the ideal spectrometer, not considering the background counts, which may have considerable effects on the uncertainties in real life. To obtain number density, bulk velocity, and temperature, different orders of moments are integrated assuming a Maxwellian velocity distribution. Based on the design specifications, we use simulations to estimate systematic and random errors for typical plasma conditions. We find that the spectrometer resolution is adequate for determining the density of solar wind (∼7% error) and magnetosheath ions (∼4% error). The resolution is also adequate for determining the temperature of solar wind (∼10% error) and magnetosheath ions (∼2% error). For high speed flows with a bulk velocity of 750 km/s and a temperature of 20 eV, the maximum density and temperature errors become 9% and 7%, respectively. The bulk velocity errors are less than 2% for all cases. The contributions of heavy ions to the systematic errors are less than 5% for magnetosheath ions and less than 8% for solar wind ions.
In deep-space exploration, Pickup Ion Analyzers (PUIAs) operate under varying thermal environments in orbit, where thermally induced stress–deformation coupling may severely degrade their performance and long-term stability. To address temperature field analysis for in-orbit PUIAs, in this study, we propose a coupled simulation framework integrating external heat flux, parallel temperature field calculation, and thermoelastic deformation analysis, establishing a systematic link from thermal inputs to performance analysis. Based on external heat flux results, a parallel LU decomposition algorithm reduced the computational time from 11.8 h to 2.9 h for rapid temperature field solutions. At 38 astronomical units (AUs), the instrument’s temperature distribution ranged from −45 °C to 51.13 °C, with simulation errors compared to COMSOL simulations meeting engineering accuracy requirements. Maximum thermoelastic deformation induced by thermal gradients reached 0.110 mm. Performance degradation due to deformation in key metrics—including ion energy resolution, angular resolution, detection field-of-view, geometric factor, and mass resolution—was below 7.2%. This research improves the computational efficiency of the temperature field and systematically quantifies temperature effects on PUIA performance in deep-space environments, and the proposed methodology could provide technical support for optimizing on-orbit thermal management strategies.
In recent years, the enthusiasm for deep space missions has remained unabated, resulting in continuous advancements in the research field of space environment and particles. Many instruments carried on these missions have conducted detection of pickup ions (PUIs) in the solar system. For those instruments, simulation is an effective means and a crucial step for their performance optimization and future operation in-orbit. It holds great significance for the instrument’s in-orbit performance assessment, science operation optimization, and detection efficiency enhancement. In this paper, the traditional probability model and the Vasyliunas and Siscoe (V–S) model are used to generate the PUIs, which are the input for the simulation of the PUI detector. For further analysis, the numerical results of the simulation are processed to calculate the instrument’s geometric factor, mass resolution, and count rates. Then, two sets of experiments are carried out for the comparison of the traditional probability model and the V–S model. The results show that, for the simulation of the instrument in the design stage, the simulation results of the traditional probability model and the V–S model are not much different. However, for the simulation of the instrument performance in-orbit, the PUI data generated based on the V–S model gave a better result than those of the traditional probability model. This conclusion is of great significance for evaluating the detection ability of the PUI detector in future deep space explorations.