Lei Miao

Dr. Lei Miao

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2015 in Fire Safety Journal
Verified
Journal Article
Closed access
W.K. ChowW.K. Chow
W.K. Chow
YGY. Gao
Y. Gao
JZJ.H. Zhao
J.H. Zhao
JDJ.F. Dang
J.F. Dang
Cheuk Lun ChowCheuk Lun Chow
Cheuk Lun Chow
LMLei Miao
Lei Miao

12 September 2019 in Journal of Thermal Analysis and Calorimetry
Verified
Journal Article
Closed access
PDF file
TGTing Gan
Ting Gan
Tingzhen MingTingzhen Ming
Tingzhen Ming
WFWeijie Fang
Weijie Fang
YLYang Liu
Yang Liu
LMLei Miao
Lei Miao
MAMohammad Hossein Ahmadi
Mohammad Hossein Ahmadi

1 January 2018 in Applied Thermal Engineering
Verified
Journal Article
Closed access
LMLei Miao
Lei Miao
CCCheuk Lun Chow
Cheuk Lun Chow

15 March 2018 in Fire Technology
Verified
Journal Article
Closed access
PDF file
W.K. ChowW.K. Chow
W.K. Chow
YGY. Gao
Y. Gao
JZJ. F. Zou
J. F. Zou
QLQ. K. Liu
Q. K. Liu
CCC. L. Chow
C. L. Chow
LMLei Miao
Lei Miao

1 February 2018 in Applied Thermal Engineering
Verified
Journal Article
Closed access
YYYuzhuo Yang
Yuzhuo Yang
LMLei Miao
Lei Miao
Cheuk Lun ChowCheuk Lun Chow
Cheuk Lun Chow

8 October 2018 in Indoor and Built Environment
Verified
Journal Article
Closed access
LMLei Miao
Lei Miao
Cheuk Lun ChowCheuk Lun Chow
Cheuk Lun Chow
Integrating photovoltaic (PV) panels with building envelope or roof to give building- integrated photovoltaic system is now widely used for conservation of energy. PV panels are also installed on double-skin facade (DSF). The window ejecting flame caused by adjacent compartment fire to the cavity may lead to fire in the PV system. To understand the effect of burning PV panels on fire hazard, experimental investigation of burning PV panels in a DSF rig was reported in this paper. To simulate the PV-DSF compartment system, a model rig with a combustion chamber connected to an 8 m tall vertical shaft was built. A 3.5 MW gasoline pool fire of diameter 1.16 m was placed inside the chamber. Four PV panels were installed on the shaft model wall opposite to the chamber model with a vertical facade (back-layer) facing the cavity. Gas temperatures inside the facade cavity in cases with PV panels on the DSF were much higher than in cases without PV panels. The present study shows that burning PV panels inside the DSF cavity could aggravate the fire hazard scenario and should be considered seriously in building design and fire safety management.