Zachary Levine

Dr. Zachary Levine

orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 July 2012 in Journal of the Optical Society of America B
Verified
Journal Article
Closed access
PDF file
ZLZachary Levine
Zachary Levine
TGThomas Gerrits
Thomas Gerrits
AMAlan L. Migdall
Alan L. Migdall
DSDaniel V. Samarov
Daniel V. Samarov
BCBrice Calkins
Brice Calkins
SNSae Woo Nam
Sae Woo Nam
Improving photon-number resolution of single-photon sensitive detectors is important for many applications, as is extending the range of such detectors. Here we seek improved resolution for a particular superconducting transition-edge sensor (TES) through better processing of the TES output waveforms. With that aim, two algorithms to extract number resolution from TES output waveforms are compared. The comparison is done by processing waveform data sets from a TES illuminated at nine illumination levels by a pulsed laser at 1550 nm. The algorithms are used to sort the individual output waveforms and then create clusters associated with individual photon numbers. The first uses a dot product with the waveform mean (for each illumination level), while the second uses K-means clustering modified to include knowledge of the Poisson distribution. The first algorithm is shown to distinguish adjacent peaks associated with photon numbers up to 19, whereas the second algorithm distinguishes photon numbers up to 23, using the same data.

22 May 2019 in Journal of Research of the National Institute of Standards and Technology
Verified
Journal Article
Closed access
ZLZachary Levine
Zachary Levine
TBTimothy J. Blattner
Timothy J. Blattner
APAdele P. Peskin
Adele P. Peskin
APAdam L. Pintar
Adam L. Pintar
Fundamental limits for the calculation of scattering corrections within X-ray computed tomography (CT) are found within the independent atom approximation from an analysis of the cross sections, CT geometry, and the Nyquist sampling theorem, suggesting large reductions in computational time compared to existing methods. By modifying the scatter by less than 1 %, it is possible to treat some of the elastic scattering in the forward direction as inelastic to achieve a smoother elastic scattering distribution. We present an analysis showing that the number of samples required for the smoother distribution can be greatly reduced. We show that fixed forced detection can be used with many fewer points for inelastic scattering, but that for pure elastic scattering, a standard Monte Carlo calculation is preferred. We use smoothing for both elastic and inelastic scattering because the intrinsic angular resolution is much poorer than can be achieved for projective tomography. Representative numerical examples are given.

10 June 2022 in Optics Express
Verified
Journal Article
Closed access
ZGZhen Guo
Zhen Guo
JSJung Ki Song
Jung Ki Song
GBGeorge Barbastathis
George Barbastathis
MGMichael E. Glinsky
Michael E. Glinsky
CVCourtenay T. Vaughan
Courtenay T. Vaughan
ZLZachary Levine
Zachary Levine
X-ray tomography is capable of imaging the interior of objects in three dimensions non-invasively, with applications in biomedical imaging, materials science, electronic inspection, and other fields. The reconstruction process can be an ill-conditioned inverse problem, requiring regularization to obtain satisfactory results. Recently, deep learning has been adopted for tomographic reconstruction. Unlike iterative algorithms which require a distribution that is known a priori, deep reconstruction networks can learn a prior distribution through sampling the training distributions. In this work, we develop a Physics-assisted Generative Adversarial Network (PGAN), a two-step algorithm for tomographic reconstruction. In contrast to previous efforts, our PGAN utilizes maximum-likelihood estimates derived from the measurements to regularize the reconstruction with both known physics and the learned prior. Compared with methods with less physics assisting in training, PGAN can reduce the photon requirement with limited projection angles to achieve a given error rate. The advantages of using a physics-assisted learned prior in X-ray tomography may further enable low-photon nanoscale imaging.

13 March 2023 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
PSPaul Szypryt
Paul Szypryt
NNNathan Nakamura
Nathan Nakamura
DBDaniel T. Becker
Daniel T. Becker
DBDouglas A. Bennett
Douglas A. Bennett
ADAmber Dagel
Amber Dagel
JWJason W. Wheeler
Jason W. Wheeler
We report on the 1,000-element transition-edge sensor (TES) x-ray spectrometer implementation of the TOMographic Circuit Analysis Tool (TOMCAT). TOMCAT combines a high spatial resolution scanning electron microscope (SEM) with a highly efficient and pixelated TES spectrometer to reconstruct three-dimensional maps of nanoscale integrated circuits (ICs). A 240-pixel prototype spectrometer was recently used to reconstruct ICs at the 130 nm technology node, but to increase imaging speed to more practical levels, the detector efficiency needs to be improved. For this reason, we are building a spectrometer that will eventually contain 3,000 TES microcalorimeters read out with microwave superconducting quantum interference device (SQUID) multiplexing, and we currently have commissioned a 1,000 TES subarray. This still represents a significant improvement from the 240-pixel system and allows us to begin characterizing the full spectrometer performance. Of the 992 maximimum available readout channels, we have yielded 818 devices, representing the largest number of TES x-ray microcalorimeters simultaneously read out to date. These microcalorimeters have been optimized for pulse speed rather than purely energy resolution, and we measure a FWHM energy resolution of 14 eV at the 8.0 keV Cu K $\alpha$ line.

24 March 2011 in Optics Express
Verified
Journal Article
Closed access
PDF file
ZLZachary Levine
Zachary Levine
JFJingyun Fan
Jingyun Fan
JCJun Chen
Jun Chen
AMAlan L. Migdall
Alan L. Migdall
A proposal is made for the generation of polarization-entangled photon pairs from a periodically poled crystal allowing for high collection efficiency, high entanglement, and stable operation. The theory is formulated for colinear propagation for application to waveguides. The key feature of the theory is the use of type II phase matching using both the +1 and −1 diffraction orders of the poling structure. Although these conditions are fairly restrictive in terms of operating parameters, practical operating conditions can be found. For example, we find that a HeNe pump laser may be used for a periodically poled rubidium-doped potassium titanyl phosphate (Rb:KTP) waveguide to yield single mode polarization-entangled pairs. Fidelities of 0.98 are possible under practical conditions.

20 December 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ZLZachary Levine
Zachary Levine
APAdele P Peskin
Adele P Peskin
AHAndrew D Holmgren
Andrew D Holmgren
EGEdward J Garboczi
Edward J Garboczi
This paper lays the groundwork for linking Hounsfield unit measurements to the International System of Units (SI), ultimately enabling traceable measurements across X-ray CT (XCT) machines. We do this by characterizing a material basis that may be used in XCT reconstruction giving linear combinations of concentrations of chemical elements (in the SI units of mol/m3) which may be observed at each voxel. By implication, linear combinations not in the set are not observable. We formulated a model for our material basis with a set of measurements of elemental powders at four tube voltages, 80 kV, 100 kV, 120 kV, and 140 kV, on a medical XCT. The samples included 30 small plastic bottles of powders containing various compounds spanning the atomic numbers up to 20, and a bottle of water and one of air. Using the chemical formulas and measured masses, we formed a matrix giving the number of Hounsfield units per (mole per cubic meter) at each tube voltage for each of 13 chemical elements. We defined a corresponding matrix in units we call molar Hounsfield unit (HU) potency, the difference in HU values that an added mole per cubic meter in a given voxel would add to the measured HU value. We built a matrix of molar potencies for each chemical element and tube voltage and performed a singular value decomposition (SVD) on these to formulate our material basis. We determined that the dimension of this basis is two. We then compared measurements in this material space with theoretical measurements, combining XCOM cross section data with the tungsten anode spectral model using interpolating cubic splines (TASMICS), a one-parameter filter, and a simple detector model, creating a matrix similar to our experimental matrix for the first 20 chemical elements. Finally, we compared the model predictions to Hounsfield unit measurements on three XCT calibration phantoms taken from the literature. We predict the experimental HU potency values derived from our scans of chemical elements with our theoretical model built from XCOM data. The singular values and singular vectors of the model and powder measurements are in substantial agreement. Application of the Bayesian Information Criterion (BIC) shows that exactly two singular values and singular vectors describe the results over four tube voltages. We give a good account of the HU values from the literature, measured for the calibration phantoms at several tube voltages for several commercial instruments, compared with our theoretical model without introducing additional parameters. We have developed a two-dimensional material basis that specifies the degree to which individual elements in compounds effect the HU values in XCT images of samples with elements up to atomic number Z = 20. We show that two dimensions is sufficient given the contrast and noise in our experiment. The linear combination of concentrations of elements that can be observed using a medical XCT have been characterized, providing a material basis for use in dual-energy reconstruction. This approach provides groundwork for improved reconstruction and for the link of Hounsfield units to the SI.