Bambang Hari Priyambodo

Dr. Bambang Hari Priyambodo


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 May 2023 in International Journal on Interactive Design and Manufacturing (IJIDeM)
Verified
Journal Article
Closed access
PDF file
HHHasdiansah Hasdiansah
Hasdiansah Hasdiansah
RYRizqi Ilmal Yaqin
Rizqi Ilmal Yaqin
PPPristiansyah Pristiansyah
Pristiansyah Pristiansyah
MUMega Lazuardi Umar
Mega Lazuardi Umar
BPBambang Hari Priyambodo
Bambang Hari Priyambodo

1 July 2021 in Materials
Verified
Journal Article
Open access
PDF file
KNKacuk Cikal Nugroho
Kacuk Cikal Nugroho
U UBAIDILLAHU UBAIDILLAH
U UBAIDILLAH
RARetna Arilasita
Retna Arilasita
MMMargono margono
Margono margono
BPBambang Hari Priyambodo
Bambang Hari Priyambodo
Seung-Bok ChoiSeung-Bok Choi
Seung-Bok Choi
This study investigated the effect of adding strontium (Sr)-doped cobalt ferrite (CoFe2O4) nanoparticles in carbonyl iron particle (CIP)-based magnetorheological fluids (MRFs). Sr-CoFe2O4 nanoparticles were fabricated at different particle sizes using co-precipitation at calcination temperatures of 300 and 400 °C. Field emission scanning electron microscopy (FESEM) was used to evaluate the morphology of the Sr-CoFe2O4 nanoparticles, which were found to be spherical. The average grain sizes were 71–91 nm and 118–157 nm for nanoparticles that had been calcinated at 300 and 400 °C, respectively. As such, higher calcination temperatures were found to produce larger-sized Sr-CoFe2O4 nanoparticles. To investigate the rheological effects that Sr-CoFe2O4 nanoparticles have on CIP-based MRF, three MRF samples were prepared: (1) CIP-based MRF without nanoparticle additives (CIP-based MRF), (2) CIP-based MRF with Sr-CoFe2O4 nanoparticles calcinated at 300 °C (MRF CIP+Sr-CoFe2O4-T300), and (3) CIP-based MRF with Sr-CoFe2O4 nanoparticles calcinated at 400 °C (MRF CIP+Sr-CoFe2O4-T400). The rheological properties of these MRF samples were then observed at room temperature using a rheometer with a parallel plate at a gap of 1 mm. Dispersion stability tests were also performed to determine the sedimentation ratio of the three CIP-based MRF samples.

14 July 2017 in Materials Science Forum
Verified
Journal Article
Closed access
PDF file
PIPriyo Tri Iswanto
Priyo Tri Iswanto
VMViktor Malau
Viktor Malau
BPBambang Hari Priyambodo
Bambang Hari Priyambodo
TWTrio Nur Wibowo
Trio Nur Wibowo
NANur Amin
Nur Amin
AISI 304 is a type of stainless steel used for load bearing implants due to relatively low cost. However, its mechanical properties and corrosion resistance must be improved to the level of AISI 316L, cobalt-based alloys, titanium and titanium alloy properties. Its fatigue characteristic is also one of the most important criteria have to be evaluated to achieve the overall service performance requirements, when this material subjected to dynamic load. High surface hardness may delay fatigue crack initiation and decrease corrosion rate because these two processes initiated at surface layer. The purpose of this research is to investigate the change in mechanical and corrosion characteristics of AISI 304 due to shot peening processes.Surface treatment with shot peening process were done by regulating the variation time for 0, 5, 10, 20, 30 and 40 minutes at the firing pressure of 7 bar; using 0,6 mm steel ball with hardness of 40-50 HRC. Firing distance between the nozzle with the specimen surface is 100 mm. Surface hardness was tested using indentation load of 10 grams for 10 seconds. Pitting corrosion test of treated AISI304 and non treated AISI316L was conducted in intravenous Otsu-RL brands as corrosion media. Pitting corrosion was performed using cyclic polarization methodThe hardness of surface layer increase with increasing shot-peening time. According to increase of length of shot-peening time from 0, 5, 10, 20, 30 and 40 minutes the hardness of these specimen increase to 241, 404, 418, 437, 481 and 496 VHN, respectively. The pitting corrosion rate tend to significantly decrease with increasing of shot peening time. According to increase of length of shot peening time from 0, 5, 10, 20, 30 and 40 minutes the pitting corrosion rate of these specimen also decrease to 0.853, 0.619, 0.086, 0.017, 0.116 and 0.036 mpy, respectively. Pitting corrosion rate of AISI316L is 0.042 mpy. Best pitting corrosion rate of treated AISI304 is 2.5 times smaller than that of non treated AISI316L. Therefore, shot-peening could be used to increase hardness number and reduce pitting corrosion rate, significanly.

1 January 2020 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
BPBambang Hari Priyambodo
Bambang Hari Priyambodo
SUSuhartoyo
Suhartoyo
SSSugeng Slamet
Sugeng Slamet
Cu35Zn is a metal with a copper matrix that has the properties of forgings and has good corrosion resistance. Cu35Zn is commonly known as brass metal. Brass is widely used by industry to make various metal components. Brass for engine components must be able to withstand statistical and dynamic loads. One of these components is a ship propeller made of brass. These components must be able to withstand axial loads and have high corrosion resistance. To improve physical and mechanical properties, surface treatment needs to be done with the shot peening method. Shot peening is done with steel shot ball with a diameter of 0.5 mm with a hardness of 40-50 HRC. Shooting distance between nozzles and 100 mm specimens for 4, 6 and 8 minutes. The shot peening pressure varies 7, 8 and 9 bars. Corrosion tests according to the ASTM G5-94 standard are carried out in a 3.5% NaCl solution, instead of seawater. The results showed an increase in the best corrosion resistance of 0.028 mpy at 8 Bar shot pressure, which is 2.8 times compared to raw materials.

25 January 2022 in Materials Science Forum
Verified
Journal Article
Closed access
PDF file
BPBambang Hari Priyambodo
Bambang Hari Priyambodo
MMMargono Margono
Margono Margono
KNKacuk Cikal Nugroho
Kacuk Cikal Nugroho
AISI 304 is widely used as biomedical material due to its lower cost and availability, but low corrosion resistance. The shot peening method can increase the mechanical characteristics and corrosion resistance of a surface. The purpose of this study was to determine the effect of shot peening surface treatment with a combination of steel ball diameter variations and pressure on corrosion resistance of AISI 304 material. Shot peening treatment was carried out using variations of 0.2, 0.5, and 0.8 mm steel ball diameters with a hardness of around 40-50 HRC. Shot peening pressure varies from 7, 8, and 9 bar. Corrosion rate testing was carried out using bovine serum media. The results showed that the best increase in corrosion resistance was 0.117 mpy for a steel ball diameter of 0.5 mm with a pressure of 9 bar, 3 times lower than that of non-treated specimens, which was 0.378 mpy.

13 November 2023 in Quantum Teknika : Jurnal Teknik Mesin Terapan
Verified
Journal Article
Open access
PDF file
RFRauuf Nur Fattah
Rauuf Nur Fattah
SSSugiyanto Sugiyanto
Sugiyanto Sugiyanto
BPBambang Hari Priyambodo
Bambang Hari Priyambodo
ANAchmad Nurhidayat
Achmad Nurhidayat
RYRizqi Ilmal Yaqin
Rizqi Ilmal Yaqin
This study used an experimental research method, which is a research method that aims to understand the causal process by treatment and conducting controlled testing on a sample of research subjects. This research uses quantitative methods by taking research data in the form of numbers. The material used in this study is the gear sprocket. A gear sprocket is a motor component that transmits power from the engine to the rear wheels so that the motor can run optimally. The sprocket gear was heat treated at 850 ℃ with a holding time of 20 minutes. The variations of quenching media are mineral water, dromus coolant, and SAE 40 oil. Hardness and microstructure tests were carried out for each specimen to determine the effect of different cooling media on the quenching process. The results of this study indicate the highest specimen hardness value was obtained at 301 HV by immersion in mineral water media. The lowest hardness was obtained at 207 HV with SAE 40 oil media immersion. Meanwhile, the non-treatment material hardness is 150 HV. In this case, there was an increase in the highest hardness of about two times compared to non-treated specimens. Observation of the microstructure shows that the grain size of the mineral water quenching specimens looks smaller than that of the non-treatment models. This phenomenon supports the idea that quenching can increase the surface hardness of the gear sprocket.