The ongoing outbreak of COVID-19 has been announced by the World Health Organization as a worldwide public health emergency. The aim of this study was to distinguish between severe and non-severe patients in early diagnosis. The results showed that the mortality of COVID-19 patients increased accompanied by age. Host factors CRP, IL-1β, hs-CRP, IL-8, and IL-6 levels in severe pneumonia patients were higher than in non-severe patients. CD3, CD8, and CD45 counts were decreased in COVID-19 patients. The results of this study suggest that the K-values of CD45 might be useful in distinguishing between severe and non-severe cases. The cut-off value for CD45 was -94.33. The K-values for CD45 in non-severe case were above the cut-off values, indicating a 100% prediction success rate for severe and non-severe cases following SARS-CoV-2 infection. The results confirmed that immune system dysfunction is a potential cause of mortality following COVID-19 infection, particularly for the elderly. CD45 deficiency dysfunction the naïve and memory T lymphocytes which may affects the long-term effectiveness of COVID-19 vaccines. K-values of CD45 might be useful in distinguishing between severe and non-severe cases in the early infection. May be CD45 could increase the diagnostic sensitivity.
Purpose: To evaluate the accuracy of pulmonary nodule (PN) detection in overweight or obese adult patients using ultralow‐dose computed tomography (ULDCT) with tin filtration at 100 kV and advanced model‐based iterative reconstruction (ADMIRE).Methods: Eighty‐one patients with body mass indices of ≥25 kg/m2 were enrolled. All patients underwent low‐dose chest CT (LDCT), followed by ULDCT. Two radiologists experienced in LDCT established the standard of reference (SOR) for PNs. The number, type, size, and location of PNs were identified in the SOR. Effective dose, objective image quality (IQ), and subjective IQ based on two radiologists’ scores were compared between ULDCT and LDCT. The detection performances of radiologists based on ULDCT were calculated according to the nodule analyses. Logistic regression was used to test for independent predictors of PN detection sensitivity.Results: Both the effective dose and objective IQ were lower for ULDCT than for LDCT (both p < 0.001). Both radiologists rated the subjective IQ of the overall IQ on ULDCT to be diagnostically sufficient. In total, 234 nodules (mean diameter, 3.4 ± 1.9 mm) were classified into 32 subsolid, 149 solid, and 53 calcified nodules according to the SOR. The overall sensitivity of ULDCT for nodule detection was 93.6%. Based on multivariate analyses, the nodule types (p = 0.015) and sizes (p = 0.013) were independent predictors of nodule detection.Conclusions: Compared with LDCT, ULDCT with tin filtration at 100 kV and ADMIRE could significantly reduce the radiation dose in overweight or obese patients while maintaining good sensitivity for nodule detection.