Hyun Joon Shim

Dr. Hyun Joon Shim

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 December 2015 in Journal of Audiology and Otology
Verified
Journal Article
Open access
PDF file
HSHyun Joon Shim
Hyun Joon Shim
MKMin Young Kwak
Min Young Kwak
YAYong-Hwi An
Yong-Hwi An
DKDong Hyun Kim
Dong Hyun Kim
YKYun Jin Kim
Yun Jin Kim
HKHyo Jung Kim
Hyo Jung Kim
A recent study demonstrated that tinnitus could be eliminated by vagus nerve stimulation (VNS) paired with notched sounds in a rat tinnitus model. The aims of this clinical study were to investigate the effects and safety of transcutaneous VNS (tVNS) by patch-type electrode paired with notched music for treating chronic tinnitus. Thirty patients with refractory chronic tinnitus for >12 months were included in this study. A patch-type electrode was attached to the auricular concha of the patient's left ear and tVNS was performed for 30 min (pulse rate 25 Hz, pulse width 200 µs, and amplitude 1-10 mA) using a transcutaneous electric nerve stimulation eco2. During tVNS, the patients listened to notched music cleared of the frequency spectrum corresponding to the tinnitus with a 0.5 octave notch width. After 10 treatment sessions, 15/30 patients (50%) reported symptom relief in terms of a global improvement questionnaire. The mean tinnitus loudness (10-point scale) and the mean tinnitus awareness score (%) improved significantly from 6.32±2.06 to 5.16±1.52 and from 82.40±24.37% to 65.60±28.15%, respectively (both p<0.05). None of the patients had any specific side effects, such as changes in heart rate or blood pressure. This study has demonstrated the feasibility and safety of tVNS paired with notched music therapy in patients with chronic tinnitus, with the use of a pad-type electrode attached to the auricular concha.

21 October 2015 in Journal of Neuroscience
Verified
Journal Article
Open access
IMIl Joon Moon
Il Joon Moon
JWJong-Ho Won
Jong-Ho Won
HKHyun Woo Kang
Hyun Woo Kang
DKDong Hyun Kim
Dong Hyun Kim
YAYong-Hwi An
Yong-Hwi An
HSHyun Joon Shim
Hyun Joon Shim
Although cochlear damage is believed to trigger the perception of tinnitus in the central auditory system, its pathophysiological mechanism is still unclear. We aimed to investigate the pathophysiology of tinnitus using psychoacoustic assessments of auditory spectral and temporal resolution and speech perception in noise. Human subjects with tinnitus and symmetric hearing thresholds were divided into three groups: nine unilateral tinnitus subjects with normal hearing thresholds (Group 1), 12 unilateral tinnitus subjects with hearing loss (HL; Group 2), and nine bilateral tinnitus subjects with HL. Fifteen normal-hearing subjects without tinnitus were also tested as a control group. Four different tests were administered: (1) the spectral-ripple discrimination (SRD) test, (2) the temporal modulation detection (TMD) test, (3) the Schroeder-phase discrimination (SPD) test, and (4) the speech recognition threshold (SRT) in noise test. There were no significant differences in SRD, TMD, and SPD between the tinnitus-affected ears (TEs) and non-tinnitus ears (NTEs) in Groups 1 and 2 (p> 0.05). In contrast, the TEs showed poorer SRTs than the NTEs in these two subject groups (p= 0.022 and 0.049). No inferiority of spectral/temporal resolution in TEs compared with NTEs suggests that there may be no more outer hair cell (OHC) damage on the tinnitus side given that damaged OHCs are associated with broadening the auditory filters. The decoupling of the SRT results from the spectral/temporal resolution data could imply that the occurrence of tinnitus does not depend upon the degree of damage to the OHCs, but rather upon different plastic changes in the central auditory system after cochlear damage.SIGNIFICANCE STATEMENTWe can easily find unilateral tinnitus patients who have symmetric hearing thresholds. Our research question was what kind of difference would be responsible for the tinnitus in the tinnitus-affected ears but not in the non-tinnitus ears of subjects with symmetric hearing thresholds. The answer to this fundamental question could help us to understand the pathophysiology of tinnitus. We evaluated the potential influence of tinnitus upon the subjects' auditory spectral and temporal resolution and speech perception in noise by comparing these psychoacoustic performances between tinnitus-affected ears and non-tinnitus ears in the same subjects.

18 December 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
HSHyun Joon Shim
Hyun Joon Shim
YAYong-Hwi An
Yong-Hwi An
DKDong Hyun Kim
Dong Hyun Kim
JYJi Eun Yoon
Ji Eun Yoon
Recently, “hidden hearing loss” with cochlear synaptopathy has been suggested as a potential pathophysiology of tinnitus in individuals with a normal hearing threshold. Several studies have demonstrated that subjects with tinnitus and normal audiograms show significantly reduced auditory brainstem response (ABR) wave I amplitudes compared with control subjects, but normal wave V amplitudes, suggesting increased central auditory gain. We aimed to reconfirm the “hidden hearing loss” theory through a within-subject comparison of wave I and wave V amplitudes and uncomfortable loudness level (UCL), which might be decreased with increased central gain, in tinnitus ears (TEs) and non-tinnitus ears (NTEs). Human subjects included 43 unilateral tinnitus patients (19 males, 24 females) with normal and symmetric hearing thresholds and 18 control subjects with normal audiograms. The amplitudes of wave I and V from the peak to the following trough were measured twice at 90 dB nHL and we separately assessed UCLs at 500 Hz and 3000 Hz pure tones in each TE and NTE. The within-subject comparison between TEs and NTEs showed no significant differences in wave I and wave V amplitude, or wave V/I ratio in both the male and female groups. Individual data revealed increased V/I amplitude ratios > mean + 2 SD in 3 TEs, but not in any control ears. We found no significant differences in UCL at 500 Hz or 3000 Hz between the TEs and NTEs, but the UCLs of both TEs and NTEs were lower than those of the control ears. Our ABR data do not represent meaningful evidence supporting the hypothesis of cochlear synaptopathy with increased central gain in tinnitus subjects with normal audiograms. However, reduced sound level tolerance in both TEs and NTEs might reflect increased central gain consequent on hidden synaptopathy that was subsequently balanced between the ears by lateral olivocochlear efferents.

1 January 2011 in Clinical and Experimental Otorhinolaryngology
Verified
Journal Article
Open access
PDF file
ACA Young Choi
A Young Choi
HSHyun Joon Shim
Hyun Joon Shim
SLSung Hee Lee
Sung Hee Lee
SYSang Won Yoon
Sang Won Yoon
EJEun-Jeong Joo
Eun-Jeong Joo
In the present study, we investigated whether speech-related cognitive function and speech recognition ability under background noise in adults with hearing impairment are improved with the use of hearing aids. Participants were recruited from the ENT Department of Eulji Hospital from September 2008 to July 2009. The study group comprised 18 participants (mean age, 69.5±8.3 years) with sensorineural hearing loss who were fitted with hearing aids, and the control group comprised 11 participants of equivalent age (mean age, 63.1±11.8 years) who were not fitted with hearing aids. All participants were assessed using the computerized Korean visual verbal learning test (VVLT) and words-in-noise (WIN) test prior to fitting of hearing aids for the study group and initially for the control group. Both groups were reassessed in both tests after 6 months. For each group, differences in the results between the two assessments were compared using the Friedman test. There was no difference in mean age between the study group and control group. In the study group, total VVLT score (reflecting short-term memory) was significantly improved from before hearing aid use to 6 months after hearing aid use (P0.05). The speech-related cognitive function of individuals with hearing impairment improved after using hearing aids. This finding indicates that hearing aids may induce acclimatization of the central auditory system.

1 January 2014 in Korean Journal of Audiology
Verified
Journal Article
Open access
PDF file
KYKwang Kyu Yu
Kwang Kyu Yu
CCChi Ho Choi
Chi Ho Choi
YAYong-Hwi An
Yong-Hwi An
MKMin Young Kwak
Min Young Kwak
SGSoo Jung Gong
Soo Jung Gong
HSHyun Joon Shim
Hyun Joon Shim
To compare the effectiveness of monitoring cisplatin-induced ototoxicity in adult patients using extended high-frequency pure-tone audiometry (EHF-PTA) or distortion-product otoacoustic emission (DP-OAE) and to evaluate the concurrence of ototoxicity and nephrotoxicity in cisplatin-treated patients. EHF-PTA was measured at frequencies of 0.25, 0.5, 1, 2, 3, 4, 6, 8, 9, 11.2, 12.5, 14, 16, 18, and 20 kHz and DP-OAE at frequencies of 0.5, 0.75, 1, 1.5, 2, 3, 4, 6, and 8 kHz in cisplatin-treated patients (n=10). Baseline evaluations were made immediately before chemotherapy and additional tests were performed before each of six cycles of cisplatin treatment. Laboratory tests to monitor nephrotoxicity were included before every cycle of chemotherapy. Four of 10 patients showed threshold changes on EHF-PTA. Five of 10 patients showed reductions in DP-OAE, but one was a false-positive result. The results of EHF-PTA and DP-OAE were consistent in two patients. Only one patient displayed nephrotoxicity on laboratory tests after the third cycle. In our study, the incidence rate of cisplatin-induced ototoxicity was 40% with EHF-PTA or DP-OAE. Although both EHF-PTA and DP-OAE showed the same sensitivity in detecting ototoxicity, they did not produce the same results in all patients. These two hearing tests could be used to complement one another. Clinicians should use both tests simultaneously in every cycle of chemotherapy to ensure the detection of ototoxicity.

1 July 2012 in Otology & Neurotology
Verified
Journal Article
Closed access
YAYong-Hwi An
Yong-Hwi An
LLLae Hyung Lee
Lae Hyung Lee
SYSang Won Yoon
Sang Won Yoon
SJSo Young Jin
So Young Jin
HSHyun Joon Shim
Hyun Joon Shim
Objective To investigate whether tinnitus affects sound localization ability. Study Design Prospective controlled study. Setting Tertiary referral center. Patients Forty tinnitus patients (mean age, 36.7 ± 14.3 yr; hearing threshold, <20 dB HL; tinnitus group) and 40 controls (mean age, 39.3 ± 12.9 yr; hearing threshold, <20 dB HL; control group). Methods We performed a sound localization test (SLT) with 7 speakers positioned in a semicircle on the horizontal plane at a distance of 1 m from the subject, at 30-degree intervals. Subjects were asked to identify the stimulus-presenting speaker, through a forced-choice procedure. The error score was calculated by scoring 1 point for each 30 degrees of difference between the stimulus-presenting speaker and the speaker identified by the subject. Results The mean SLT total error score (TES) of the tinnitus group (18.8 ± 9.2) was significantly higher than that of the control group (13.1 ± 7.5) (p < 0.05). Regarding SLT responses for stimulation from speakers located at each side of the listener, mean TES in patients with tinnitus on the same side as the speaker was higher than that in patients with opposite side or bilateral tinnitus. Age showed a positive correlation with TES in the tinnitus (r = 0.44, p < 0.05) and control groups (r = 0.35, p < 0.05). Conclusion We consider that tinnitus interferes with sound localization ability and that interference is worse for sound originating from the same side as the tinnitus. Age is a worsening factor in sound localization ability.