Eun-Chul Kang

Eun-Chul Kang


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 April 2020 in Energies
Verified
Journal Article
Open access
PDF file
YKYu Jin Kim
Yu Jin Kim
KLKwang Seob Lee
Kwang Seob Lee
LYLibing Yang
Libing Yang
Entchev EvgueniyEntchev Evgueniy
Entchev Evgueniy
EKEun-Chul Kang
Eun-Chul Kang
ELE J Lee
E J Lee
Photovoltaic-Thermal (PVT) is a type of technology that generates electricity and heat simultaneously at the point of use. The generated electricity could be used on site or exported to the grid while the thermal output could be utilized for space and water heating. There is a lot of research for solar air heating with experiment or CFD (Computational Fluid Dynamics), but CFD has the disadvantage that it would indicate impractical results. In this paper, a numerical PVT baseline model was developed and validated with Separate Effect Test (SET) data to increase reliability. The numerical study was conducted by considering the effect of baffle lengths and baffle slopes on outlet temperature, total heat transfer and pressure drop inside PVT air module. An optimum PVT baffle length and slope design were suggested. The baseline numerical PVT model agreed well with the test data set as indicated by 1.25% error for inlet–outlet temperatures difference. The sensitivity study was conducted by changing the PVT baffle length and slope. The optimum baffle design was concerned with both heat transfer and pressure drop at the same time with ratio. The baffle length should be kept under 150 mm and baffle slope should be greater than 30° to achieve better air mixing in PVT air channel and unit heat transfer compared to baffle slope less than 30°.

16 January 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MGMohamed Gaber Ghorab
Mohamed Gaber Ghorab
LYLibing Yang
Libing Yang
Entchev EvgueniyEntchev Evgueniy
Entchev Evgueniy
ELE J Lee
E J Lee
EKEun-Chul Kang
Eun-Chul Kang
KKKwonye Kim
Kwonye Kim
Hybrid renewable energy systems are subject to extensive research around the world and different designs have found their way to the market and have been commercialized. These systems usually employ multiple components, both renewable and conventional, combined in a way to increase the system’s overall efficiency and resilience and to lower GHG emissions. In this paper, a hybrid renewable energy system was designed for residential use and its annual energy performance was investigated and optimized. The multi-module hybrid system consists of a Ground-Air Heat Exchanger (GAHX), Photovoltaic Thermal (PVT) panels and Air to Water Heat Pump (AWHP). The developed system’s annual performance was simulated in the TRaNsient SYStem (TRNSYS) environment and optimized using the General Algebraic Modelling System (GAMS) platform. Multi-objective non-linear optimization algorithms were developed and applied to define optimal system design and performance parameters while reducing cost and GHG emissions. The results revealed that the designed system was able to satisfy building thermal heating/cooling loads throughout the year. The ground source heat exchanger contributed 21.3% and 26.3% of the energy during heating and cooling seasons, respectively. The initial design was optimized in terms of key performance parameters and module sizes. The annual simulation analysis showed that the system was able to self-generate and meet nearly 29.4% of the total HVAC electricity needs, with the rest being supplied by the grid. The annual system module performance efficiencies were 13.4% for the PVT electric and 5.5% for the PVT thermal, with an AWHP COP of 4.0.

20 September 2016 in Energies
Verified
Journal Article
Open access
PDF file
EKEun-Chul Kang
Eun-Chul Kang
ELE J Lee
E J Lee
MGMohamed Ghorab
Mohamed Ghorab
LYLibing Yang
Libing Yang
Entchev EvgueniyEntchev Evgueniy
Entchev Evgueniy
NLNam-Jin Lyu
Nam-Jin Lyu
Micro polygeneration utilizing renewable energy is a suitable approach to reduce energy consumption and carbon emission by offering high-efficiency performance, offsetting the need for centrally-generated grid electricity and avoiding transmission/distribution losses associated with it. This paper investigates the energy and environmental potential of a renewable trigeneration system in a residential application under Incheon (Korea) and Ottawa (Canada) weather conditions. The trigeneration system consists of a ground-to-air heat exchanger (GAHX), photovoltaic thermal (PVT) panels and an air-to-water heat pump (AWHP). The study is performed by simulations in TRNSYS (Version 17.02) environment. The performance of the trigeneration system is compared to a reference conventional system that utilizes a boiler for space and domestic hot water heating and a chiller for space cooling. Simulation results showed substantial annual primary energy savings from the renewable trigeneration system in comparison to the reference system—45% for Incheon and 42% for Ottawa. The CO2eq emission reduction from the renewable trigeneration system is also significant, standing at 43% for Incheon and 82% for Ottawa. Furthermore, trigeneration systems’ capability to generate electricity and thermal energy at the point of use is considered as an attractive option for inclusion in the future smart energy network applications.

29 March 2021 in Energies
Verified
Journal Article
Open access
PDF file
KKKwonye Kim
Kwonye Kim
JKJaemin Kim
Jaemin Kim
YNYujin Nam
Yujin Nam
ELE J Lee
E J Lee
EKEun-Chul Kang
Eun-Chul Kang
Entchev EvgueniyEntchev Evgueniy
Entchev Evgueniy
A ground source heat pump system is a high-performance technology used for maintaining a stable underground temperature all year-round. However, the high costs for installation, such as for boring and drilling, is a drawback that prevents the system to be rapidly introduced into the market. This study proposes a modular ground heat exchanger (GHX) that can compensate for the disadvantages (such as high-boring/drilling costs) of the conventional vertical GHX. Through a real-scale experiment, a modular GHX was manufactured and buried at a depth of 4 m below ground level; the heat exchange rate and the change in underground temperatures during the GHX operation were tracked and calculated. The average heat exchanges rate was 78.98 W/m and 88.83 W/m during heating and cooling periods, respectively; the underground temperature decreased by 1.2 °C during heat extraction and increased by 4.4 °C during heat emission, with the heat pump (HP) working. The study showed that the modular GHX is a cost-effective alternative to the vertical GHX; further research is needed for application to actual small buildings.

8 May 2018 in Energies
Verified
Journal Article
Open access
PDF file
JJJeachul Jang
Jeachul Jang
EKEun-Chul Kang
Eun-Chul Kang
HLHyung Keun Lee
Hyung Keun Lee
SJSiyoung Jeong
Siyoung Jeong
SPSeongryong Park
Seongryong Park
This communication presents the performance evaluation and comparative study between two different techniques: a membrane-based dehumidification system (MDS) and evaporative cooling dehumidification (ECD) for a typical climate of South Korea. Although there are different ways to dehumidify the air in living and work spaces, the membrane-based dehumidification system (MDS) is the most effective way as it neither causes a change in the temperature nor harms the environment. Moreover, it consumes significantly less energy when compared to other methods. There are also limitations concerning products that are sensitive to temperature such as food and pharmaceutical products; the method of evaporative cooling dehumidification is not suitable for such applications. The present work demonstrated the excellent energy-saving performance of the membrane-based dehumidification system against evaporative cooling dehumidification by comparing the performance of these two systems during the rainy season using a transient system simulation. The results showed that the MDS helped to reduce the dehumidification load by more than 47.6% when compared to the ECD system, which is a significant achievement in this regard.

24 October 2019 in Energies
Verified
Journal Article
Open access
PDF file
KLKwang Seob Lee
Kwang Seob Lee
EKEun-Chul Kang
Eun-Chul Kang
YKYu Jin Kim
Yu Jin Kim
ELE J Lee
E J Lee
Ground-air heat exchangers have become an important topic in recent years due to their contributions to the market growth of the ground source heat pump industry. This paper provides a comprehensive study and recommends suggestions on the selection process of a suitable pipe for an air-to-water heat pump (AWHP). Parametric studies including material, turbulent plate quantity, and pipe type were performed to identify an optimal pipe design for high-performance AWHP. Both numerical and experimental studies were carried out to validate current pipe models. Overall, there was good agreement between the numerical model and experimental results. It was determined that a spirally corrugated pipe exhibited excellent thermal power generation with little compromising pressure drop. Finally, a pipe selection example was demonstrated as a design guideline to size an optimal pipe for AWHP application.