The Concrete Damage Plasticity (CDP) model is a widely used constitutive model to represent the non-linear behavior of concrete in numerical analysis. However, a limited number of studies compared the level of accuracy of numerical models with the main code provisions from the literature. In addition, the influence of CDP material parameters on the structural behavior of corbels was scarcely studied. This study proposes to evaluate the ability of numerical models using CDP to represent the structural behavior of corbels regarding the ultimate load, reinforcement deformation and failure mechanism. In addition, we compared the predictions of the numerical models with the ones from design code expressions regarding the ultimate capacity. For this, three test results of corbels from the literature were evaluated with numerical models using the CDP, as well as with analytical models from different code provisions. A sensitivity analysis—by changing the dilation angle (ψ) and shape factor (Kc)—was performed. The comparison between tested and predicted resistances with the proposed numerical modeling choices was equal to 1.04 with a coefficient of variation of 11%. On the other hand, the analytical models evaluated overestimated the corbel capacity by more than 62%, on average. Therefore, the proposed modeling choices provide better predictions of ultimate capacity than the evaluated analytical models and can be used to assess the corbel design under more complex boundary conditions.
The thermal discomfort in buildings on hot days and the high levels of electricity expenditure in buildings with refrigeration systems have an economic and energetic impact on the maintenance of thermal comfort. This work presents a comparison of energy efficiency between a green roof and a fiber cement roof using a comparison carried out by temperature collection over a period of one month, highlighting the arboreal benefits and cost savings that the green roof can bring. Data collection was carried out over a period of one month at 7:00 am, 1:00 pm and 5:00 pm, measuring the temperature at these times in two reduced-scale prototypes, one with a green roof and the other with fiber cement tile. The green roof system proved to be efficient, reducing maximum temperatures and increasing minimum temperatures, keeping internal temperatures closer to current thermal performance standards.
1 January 2025 in Revista IBRACON de Estruturas e Materiais
In precast concrete systems, connections play a crucial role in ensuring structural continuity between elements and contributing to the overall stability of the structure. Among various types, semi-rigid bolted beam-to-column connections are commonly used to reduce on-site construction time. Additionally, they provide enhanced energy dissipation under seismic loading compared to cast-in-place connections. This study developed and validated a nonlinear numerical model in DIANA® software to simulate the behavior of a bolted beam-to-column connection under monotonic and cyclic loading. An analytical model was also proposed to estimate the secant stiffness of the connection. The numerical model was calibrated using experimental data available in the literature, showing a maximum error of 3% in predicting ultimate strength and 30% in energy dissipation capacity. Moreover, the model accurately represented the stiffness, cracking pattern, and global behavior of the connection. A parametric analysis was conducted to assess the influence of concrete strength, bolt diameter, and bolt steel grade on the connection performance. The comparison between cyclic and monotonic loading indicated low stiffness degradation up to the yielding of the bolts. The proposed analytical model yielded a stiffness ratio (numerical-to-analytical) of 1.00 with a coefficient of variation of 4.54%, confirming its applicability for estimating the stiffness of bolted connections.