Rachel Scheperle

Dr. Rachel Scheperle

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2017 in Hearing Research
Verified
Journal Article
Closed access
RSRachel Scheperle
Rachel Scheperle
VTViral Tejani
Viral Tejani
JOJulia K. Omtvedt
Julia K. Omtvedt
CBCarolyn J. Brown
Carolyn J. Brown
PAPaul J. Abbas
Paul J. Abbas
MOMarie Ozanne
Marie Ozanne

1 December 2011 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
RSRachel Scheperle
Rachel Scheperle
SGShawn S. Goodman
Shawn S. Goodman
SNStephen T. Neely
Stephen T. Neely
Quantifying ear-canal sound level in forward pressure has been suggested as a more accurate and practical alternative to sound pressure level (SPL) calibrations used in clinical settings. The mathematical isolation of forward (and reverse) pressure requires defining the Thévenin-equivalent impedance and pressure of the sound source and characteristic impedance of the load; however, the extent to which inaccuracies in characterizing the source and/or load impact forward pressure level (FPL) calibrations has not been specifically evaluated. This study examined how commercially available probe tips and estimates of characteristic impedance impact the calculation of forward and reverse pressure in a number of test cavities with dimensions chosen to reflect human ear-canal dimensions. Results demonstrate that FPL calibration, which has already been shown to be more accurate than in situ SPL calibration, can be improved particularly around standing-wave null frequencies by refining estimates of characteristic impedance. Better estimates allow FPL to be accurately calculated at least through 10 kHz using a variety of probe tips in test cavities of different sizes, suggesting that FPL calibration can be performed in ear canals of all sizes. Additionally, FPL calibration appears a reasonable option when quantifying the levels of extended high-frequency (10–18 kHz) stimuli.

1 March 2017 in Journal of Otology
Verified
Journal Article
Open access
RSRachel Scheperle
Rachel Scheperle
Electrically evoked compound action potential (eCAP) amplitudes elicited at suprathreshold levels were assessed as a measure of the effectiveness of cochlear implant (CI) stimulation. Twenty-one individuals participated; one was excluded due to facial stimulation during eCAP testing. For each participant, eCAPs were elicited with stimulation from seven electrodes near the upper limit of the individual's electrical dynamic range. A reduced-channel CI program was created using those same seven electrodes, and participants performed a vowel discrimination task. Consistent with previous reports, eCAP amplitudes varied across tested electrodes; the profiles were unique to each individual. In 6 subjects (30%), eCAP amplitude variability was partially explained by the impedance of the recording electrode. The remaining amplitude variability within subjects, and the variability observed across subjects could not be explained by recording electrode impedance. This implies that other underlying factors, such as variations in neural status across the array, are responsible. Across-site mean eCAP amplitude was significantly correlated with vowel discrimination scores (r2 = 0.56). A single eCAP amplitude measured from the middle of the array was also significantly correlated with vowel discrimination, but the correlation was weaker (r2 = 0.37), though not statistically different from the across-site mean. Normalizing each eCAP amplitude by its associated recording electrode impedance did not improve the correlation with vowel discrimination (r2 = 0.52). Further work is needed to assess whether combining eCAP amplitude with other measures of the electrode-neural interface and/or with more central measures of auditory function provides a more complete picture of auditory function in CI recipients.

11 June 2025 in The Laryngoscope
Verified
Journal Article
Open access
UKUzair A. Khan
Uzair A. Khan
CDCamille C. Dunn
Camille C. Dunn
RSRachel Scheperle
Rachel Scheperle
JOJacob Oleson
Jacob Oleson
ACAlexander Claussen
Alexander Claussen
MHMarlan R. Hansen
Marlan R. Hansen
Objective(s): Robotic‐assisted electrode array (EA) insertion is a promising technique that may enhance hearing preservation in cochlear implant (CI) surgery. The purpose of our study is to understand the extent to which robotic‐assisted EA insertion improves hearing preservation. Methods: Twenty‐four adult patients underwent CI surgery with manual EA insertion and 27 adult patients underwent CI surgery with robotic‐assisted EA insertion using the iotaSOFT system. The EAs used included the Flex 20/24/26. The primary outcome variable was low frequency pure‐tone average (LFPTA), defined as mean audiometric threshold at 125, 250, and 500 Hz. This was measured preoperatively, at initial activation (within 4 weeks of surgery), and subsequently at 2 weeks, 3 months, 6 months, and 1 year. Functional acoustic hearing was defined as LFPTA < 80 dB HL. Results: Seventeen out of 24 patients (71%) in the manual insertion group and 23 out of 27 patients (85%) in the robotic‐assisted EA insertion group had preserved functional acoustic hearing (< 80 dB HL) up till 1 year (Fisher's exact test (two‐tailed) is not statistically significant, p = 0.31). The number needed to treat with robotic‐assisted EA insertion to prevent one additional negative outcome of loss of functional acoustic hearing would be 7 (1/0.14). Conclusion: Robotic‐assisted EA insertion is associated with improved hearing preservation over 1 year compared with manual insertion. Hearing preservation leads to improved outcomes and therefore every effort should be made to preserve the delicate structure and function of the cochlea during EA insertion. Robotic‐assisted EA insertion advances that objective. Level of Evidence: III (cohort study).

29 November 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
RSRachel Scheperle
Rachel Scheperle
CEChristine Etler
Christine Etler
JOJacob Oleson
Jacob Oleson
CDCamille Dunn
Camille Dunn
RKRustin Kashani
Rustin Kashani
MHMarlan R. Hansen
Marlan R. Hansen
This study evaluates intracochlear electrocochleography (ECochG) for real-time monitoring during cochlear implantation. One aim tested whether adjusting the recording electrode site would help differentiate between atraumatic and traumatic ECochG amplitude decrements. A second aim assessed whether associations between ECochG amplitude decrements and post-operative hearing loss were weaker when considering hearing sensitivity at the ECochG stimulus frequency compared to a broader frequency range. Eleven adult cochlear implant recipients who were candidates for electro-acoustic stimulation participated. Single-frequency (500-Hz) ECochG was performed during cochlear implantation; the amplitude of the first harmonic of the difference waveform was considered. Post-operative hearing preservation at 500 Hz ranged from 0 to 94%. The expected relationship between ECochG amplitude decrements and hearing preservation was observed, though the trend was not statistically significant, and predictions were grossly inaccurate for two participants. Associations did not improve when considering alternative recording sites or hearing sensitivity two octaves above the ECochG stimulus frequency. Intracochlear location of a moving recording electrode is a known confound to real-time interpretation of ECochG amplitude fluctuations, which was illustrated by the strength of the correlation with ECochG amplitude decrements. Multiple factors contribute to ECochG amplitude patterns and to hearing preservation; these results highlight the confounding influence of intracochlear recording electrode location on the ECochG.

21 January 2026 in The Laryngoscope
Verified
Journal Article
Open access
UKUzair A. Khan
Uzair A. Khan
RSRachel Scheperle
Rachel Scheperle
GPGrant Podhajsky
Grant Podhajsky
MLMeggan J. Lind
Meggan J. Lind
CDCamille C. Dunn
Camille C. Dunn
MHMarlan R. Hansen
Marlan R. Hansen
Objective(s): Robotic‐assisted electrode array (EA) insertion is a promising technique that may enhance preservation of residual acoustic hearing after cochlear implant (CI) surgery. The purpose of this study is to evaluate the impact of robotic‐assisted EA insertion on rates of delayed‐onset hearing loss (DOHL). Methods: Sixty (Advanced Bionics [AB]: 30, MED‐EL: 30) adult patients underwent CI surgery with manual EA insertion and 29 (AB: 13, MED‐EL: 16) with robotic‐assisted insertion using the iotaSOFT system. The primary outcome variable was longitudinal change in low frequency pure‐tone average (LFPTA). DOHL was defined as a decrease in LFPTA of > 10 dB compared to previous best postoperative LFPTA. Results: Twenty‐two (37%) out of the 60 subjects in the manual cohort and two (7%) out of the 29 subjects in the robotic‐assisted cohort had DOHL over the entire length of available follow‐up ( p = 0.002, Fisher's exact test, two‐tailed). When evaluating DOHL results for subjects who had LFPTA data at 12 months (±4 weeks) post initial activation, 11 (29%) out of the 38 (AB: 15, MED‐EL: 23) subjects in the manual cohort and zero (0%) out of the 18 (AB: 8, MED‐EL: 10) subjects in the robotic‐assisted cohort had DOHL ( p = 0.011, Fisher's exact test, two‐tailed). The number needed to treat was 4. Conclusion: Robotic‐assisted EA insertion is associated with a clinically meaningful reduction in rates of DOHL. Preservation of residual acoustic hearing is a critical goal in CI surgery, and robotic‐assisted EA insertion contributes towards achieving this goal. Level of Evidence: 3.