Antonio Artes

Mr. Antonio Artes


Research Focus & Metrics

Academic Career Length

37Years (1990-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 June 2013 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
HKHyejung Kim
Hyejung Kim
SKSunyoung Kim
Sunyoung Kim
NHNick Van Helleputte
Nick Van Helleputte
AAAntonio Artes
Antonio Artes
MKMario Konijnenburg
Mario Konijnenburg
RYRefet Firat Yazicioglu
Refet Firat Yazicioglu
This paper describes a mixed-signal ECG System-on-Chip (SoC) that is capable of implementing configurable functionality with low-power consumption for portable ECG monitoring applications. A low-voltage and high performance analog front-end extracts 3-channel ECG signals and single channel electrode-tissue-impedance (ETI) measurement with high signal quality. This can be used to evaluate the quality of the ECG measurement and to filter motion artifacts. A custom digital signal processor consisting of 4-way SIMD processor provides the configurability and advanced functionality like motion artifact removal and R peak detection. A built-in 12-bit analog-to-digital converter (ADC) is capable of adaptive sampling achieving a compression ratio of up to 7, and loop buffer integration reduces the power consumption for on-chip memory access. The SoC is implemented in 0.18 μm CMOS process and consumes 32 μW from a 1.2 V while heart beat detection application is running, and integrated in a wireless ECG monitoring system with Bluetooth protocol. Thanks to the ECG SoC, the overall system power consumption can be reduced significantly.

8 January 2004 in IEEE Transactions on Signal Processing
Verified
Journal Article
Open access
José-Luis Rojo-ÁlvarezJosé-Luis Rojo-Álvarez
José-Luis Rojo-Álvarez
MMM. Martinez-Ramon
M. Martinez-Ramon
MDM. Deprado-Cumplido
M. Deprado-Cumplido
AAAntonio Artes
Antonio Artes
AFA.R. Figueiras-Vidal
A.R. Figueiras-Vidal
This paper presents a new approach to auto-regressive and moving average (ARMA) modeling based on the support vector method (SVM) for identification applications. A statistical analysis of the characteristics of the proposed method is carried out. An analytical relationship between residuals and SVM-ARMA coefficients allows the linking of the fundamentals of SVM with several classical system identification methods. Additionally, the effect of outliers can be cancelled. Application examples show the performance of SVM-ARMA algorithm when it is compared with other system identification methods.

7 September 2019 in BMC Psychiatry
Verified
Journal Article
Open access
PDF file
SBSofian Berrouiguet
Sofian Berrouiguet
MBMaria Luisa Barrigon
Maria Luisa Barrigon
JCJorge Lopez Castroman
Jorge Lopez Castroman
PCPhilippe Courtet
Philippe Courtet
AAAntonio Artes
Antonio Artes
EBEnrique Baca-García
Enrique Baca-García
The screening of digital footprint for clinical purposes relies on the capacity of wearable technologies to collect data and extract relevant information’s for patient management. Artificial intelligence (AI) techniques allow processing of real-time observational information and continuously learning from data to build understanding. We designed a system able to get clinical sense from digital footprints based on the smartphone’s native sensors and advanced machine learning and signal processing techniques in order to identify suicide risk. The Smartcrisis study is a cross-national comparative study. The study goal is to determine the relationship between suicide risk and changes in sleep quality and disturbed appetite. Outpatients from the Hospital Fundación Jiménez Díaz Psychiatry Department (Madrid, Spain) and the University Hospital of Nimes (France) will be proposed to participate to the study. Two smartphone applications and a wearable armband will be used to capture the data. In the intervention group, a smartphone application (MEmind) will allow for the ecological momentary assessment (EMA) data capture related with sleep, appetite and suicide ideations. Some concerns regarding data security might be raised. Our system complies with the highest level of security regarding patients’ data. Several important ethical considerations related to EMA method must also be considered. EMA methods entails a non-negligible time commitment on behalf of the participants. EMA rely on daily, or sometimes more frequent, Smartphone notifications. Furthermore, recording participants’ daily experiences in a continuous manner is an integral part of EMA. This approach may be significantly more than asking a participant to complete a retrospective questionnaire but also more accurate in terms of symptoms monitoring. Overall, we believe that Smartcrises could participate to a paradigm shift from the traditional identification of risks factors to personalized prevention strategies tailored to characteristics for each patient. NCT03720730. Retrospectively registered.

1 November 1998 in IEEE Transactions on Neural Networks
Verified
Journal Article
Closed access
FGF.J. Gonzalez-Serrano
F.J. Gonzalez-Serrano
AFA.R. Figueiras-Vidal
A.R. Figueiras-Vidal
AAAntonio Artes
Antonio Artes
The cerebellar model articulation controller (CMAC) is a simple and fast neural-network based on local approximations. However, its rigid structure reduces its accuracy of approximation and speed of convergence with heterogeneous inputs. In this paper, we propose a generalized CMAC (GCMAC) network that considers different degrees of generalization for each input. Its representation abilities are analyzed, and a set of local relationships that the output function must satisfy are derived. An adaptive growing method of the network is also presented. The validity of our approach and methods are shown by some simulated examples.

6 December 2017 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
Francisco Hernando-GallegoFrancisco Hernando-Gallego
Francisco Hernando-Gallego
DLDavid Luengo
David Luengo
AAAntonio Artes
Antonio Artes
Wearable sensors are increasingly taking part in daily activities, not only because of the recent society health concern, but also due to their relevance in the medical industry. In this paper, a galvanic skin response (GSR) extraction technique has been developed in order to interpret electrodermal activity (EDA) records, which can be useful both for ambulatory and health applications. The core of the proposed approach is a novel feature extraction scheme that is based on a nonnegative sparse deconvolution of the observed GSR signals. Unlike previous approaches, the resulting SparsEDA algorithm is fast (immediately extracting the skin conductance level and response), efficient (being able to work with any sampling rate and signal length), and highly interpretable (due to the sparsity of the extracted phasic component of the GSR). Results on real data from 100 different subjects confirm the good performance of the method, which has been released through a free web-based code repository.

4 September 2007 in IEEE Transactions on Neural Networks
Verified
Journal Article
Closed access
JLJose Miguel Leiva-Murillo
Jose Miguel Leiva-Murillo
AAAntonio Artes
Antonio Artes
In this paper, we present a novel scheme for linear feature extraction in classification. The method is based on the maximization of the mutual information (MI) between the features extracted and the classes. The sum of the MI corresponding to each of the features is taken as an heuristic that approximates the MI of the whole output vector. Then, a component-by-component gradient-ascent method is proposed for the maximization of the MI, similar to the gradient-based entropy optimization used in independent component analysis (ICA). The simulation results show that not only is the method competitive when compared to existing supervised feature extraction methods in all cases studied, but it also remarkably outperform them when the data are characterized by strongly nonlinear boundaries between classes.