Animals can easily detect hundreds of thousands of odors in the environment with high sensitivity and selectivity. With the progress of biological olfactory research, scientists have extracted multiple biomaterials and integrated them with different transducers thus generating numerous biosensors. Those biosensors inherit the sensing ability of living organisms and present excellent detection performance. In this paper, we mainly introduce odor biosensors based on substances from animal olfactory systems. Several instances of organ/tissue-based, cell-based, and protein-based biosensors are described and compared. Furthermore, we list some other biological materials such as peptide, nanovesicle, enzyme, and aptamer that are also utilized in odor biosensors. In addition, we illustrate the further developments of odor biosensors.
In recent few years, researchers utilized cell expressing olfactory receptor for vapor detection under various sensing mechanisms. Those olfactory systems, however, have relatively short lifetime due to the dry out of aqueous solution covering the cell. In this paper, we came up with a feedback control structure composed of an impedance measurement circuit, a microcontroller and two syringe pumps for maintaining thin liquid layer above cell. Cell lifetime was improved from less than 40 min to longer than 75 min when liquid film control was introduced. However, the biosensor lifetime remained similar between with or without liquid thickness control. Then, we added liquid exchange to further extend the lifetime of our odor biosensor. Minimal liquid exchange speed was able to significantly extend the biosensor lifetime. Meanwhile, faster liquid exchange speed resulted in better sensor responses. Furthermore, the enhancement acquired from intermittent liquid exchange was compared with continuous one. In this study, the lifetime of odor biosensor was extended to more than 3 h whereas it was less than half an hour without liquid thickness control. We believe the methodology we established in this paper will facilitate gas phase odor biosensor in continuous monitoring of target substances.
The OR (olfactory receptor) with its high selectivity and sensitivity attracts many researchers to apply it to numerous kinds of odor biosensors. Till now, the liquid phase odorant detection has been well studied. However, most of the odorant molecules that scientists are interested in are hydrophobic and exist in atmosphere. Meanwhile, some odorant samples to be detected are precious and hard to collect. Here, we developed a gas phase odorant detection system using cell expressing insect OR. We then tested it with target ligand as well as reference gas and obtained the typical OR response. After this, we checked the influence of stimulation duration and liquid thickness to it. Moreover, the detection limit and selectivity were confirmed by a series of experiments. In addition, the sample concentration dependency was exhibited and a hypothesis towards inhibition phenomenon was proposed. Lastly, a human sensory test was operated to compare the performance of our system with human olfaction. In our system, only sub-milliliter target odorant was enough to trigger the OR response. Altogether, these results suggest this odor biosensor can be applied to gas phase odorant detection in multiple aspects owning to its detection capability and rapid response.
In recent years, several gas-phase odor biosensors have been developed. Sensitive cells and multiple sensing elements were investigated for enhancing the performance of those biosensors. The thickness of the liquid layer that covers the cells, however, has rarely been so far explored. Recently we utilized the feedback control method to maintain a constant liquid film. Now we intended to step further about the alteration and estimation of this liquid film. Here, we developed a gas phase odor biosensor with variable liquid film thickness. The liquid layer thickness change was reflected as the impedance change between two electrodes. Thinner liquid film always resulted in greater response and faster peak time. For realizing such a thin liquid film state, withdrawing the buffer solution step by step was more preferred. Furthermore, the sample concentration dependency curves under normal and thin liquid layer conditions proved thin liquid film improved response evidently. Moreover, the weakened stability caused by thin liquid film was explained. Finally, we calculated the liquid film thickness according to the feedback control signal and validated the estimation result by manual operation. It revealed a steady liquid film thinner than 100 $\mu \text{m}$ was implemented in this system. This study demonstrated the advantages of thin liquid layer and provided an access to estimation and fine adjustment of liquid film thickness in gas phase odor biosensors.