Hideaki Ishida

Dr. Hideaki Ishida

orcid

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2001 in Abdominal Radiology
Verified
Journal Article
Closed access
PDF file
HIHideaki Ishida
Hideaki Ishida
KKK. Konno
K. Konno
JIJ. Ishida
J. Ishida
HNHiroshi Naganuma
Hiroshi Naganuma
TKT. Komatsuda
T. Komatsuda
SWSatoru Watanabe
Satoru Watanabe

27 January 2000 in European Radiology
Verified
Journal Article
Closed access
PDF file
MSM. Sato
M. Sato
HIHideaki Ishida
Hideaki Ishida
KKK. Konno
K. Konno
HNHiroshi Naganuma
Hiroshi Naganuma
TKT. Komatsuda
T. Komatsuda
SWShinya Watanabe
Shinya Watanabe

1 March 1994 in Abdominal Radiology
Verified
Journal Article
Closed access
PDF file
HNHiroshi Naganuma
Hiroshi Naganuma
HIHideaki Ishida
Hideaki Ishida
MNM. Niizawa
M. Niizawa
OMO. Masamune
O. Masamune

10 November 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
HNHiroshi Naganuma
Hiroshi Naganuma
HIHideaki Ishida
Hideaki Ishida
Hepatocellular carcinoma (HCC) in a non-fibrotic liver (F0) is considered to be rare, and there is a marked paucity of studies in the literature on this HCC type. A review of the literature shows some important clinical and tumor characteristics: (a) it occurs mainly in young female and elder male patients; (b) clinically, under normal hepatic function, alpha-fetoprotein level is often normal, and there are no risk factors; (c) associated with metabolic disease; (d) macroscopically, single large lesions are noted; and (e) microscopically, the lesions are well-differentiated and encapsulated. Radiological imaging results are straightforward, showing arterial hyperenhancement and later wash-out. The combined use of B-mode and contrast-enhanced (CE) ultrasound (US) is the most reliable and cost-effective diagnostic method. Few peri-and post-operative complications are noted and 5-year survival is not inferior to patients with HCC on fibrosis liver despite the lesion’s large size. Most clinicians believe that HCC is unlikely to occur if patients have no symptoms and normal hepatic function. Although detailed clinical data are very limited, we expect that this review will help to improve the clinical management of HCC in non-fibrotic livers.

21 June 2007 in Journal of Medical Ultrasonics
Verified
Journal Article
Closed access
PDF file
HNHiroshi Nakagawara
Hiroshi Nakagawara
MOMasahiro Ogawa
Masahiro Ogawa
NMNaoki Matsumoto
Naoki Matsumoto
YHYoshikazu Hiroi
Yoshikazu Hiroi
TYToshiki Yamamoto
Toshiki Yamamoto
HIHideaki Ishida
Hideaki Ishida

20 August 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
HNHiroshi Naganuma
Hiroshi Naganuma
HIHideaki Ishida
Hideaki Ishida
HNHiroshi Nagai
Hiroshi Nagai
AUAtushi Uno
Atushi Uno
Contrast-enhanced sonography (CEUS) is a very important diagnostic imaging tool in clinical settings. However, it is associated with possible artifacts, such as B-mode US-related artifacts. Sufficient knowledge of US physics and these artifacts is indispensable to avoid the misinterpretation of CEUS images. This review aims to explain the basic physics of CEUS and the associated artifacts and to provide some examples to avoid them. This review includes problems related to the frame rate, scanning modes, and various artifacts encountered in daily CEUS examinations. Artifacts in CEUS can be divided into two groups: (1) B-mode US-related artifacts, which form the background of the CEUS image, and (2) artifacts that are specifically related to the CEUS method. The former includes refraction, reflection, reverberation (multiple reflections), attenuation, mirror image, and range-ambiguity artifacts. In the former case, the knowledge of B-mode US is sufficient to read the displayed artifactual image. Thus, in this group, the most useful artifact avoidance strategy is to use the reference B-mode image, which allows for a simultaneous comparison between the CEUS and B-mode images. In the latter case, CEUS-specific artifacts include microbubble destruction artifacts, prolonged heterogeneous accumulation artifacts, and CEUS-related posterior echo enhancement; these require an understanding of the mechanism of their appearance in CEUS images for correct image interpretation. Thus, in this group, the most useful artifact avoidance strategy is to confirm the phenomenon’s instability by changing the examination conditions, including the frequency, depth, and other parameters.