The maximum reflection at an open end of a standard rectangular waveguide is about −10 dB in its operating frequency range. It is often used without matching. For critical applications, it is desirable to further reduce the reflection coefficient. In this paper, a new technique is presented for the broadband impedance matching of an open-ended rectangular waveguide. The proposed technique employs three thin capacitive matching elements placed at proper intervals via a low-loss dielectric material. The capacitance of, and distance between, the matching elements are optimized for broadband impedance matching using a simulation tool. Based on the proposed technique, two design examples are presented for the matching of a WR75 waveguide radiator. A reflection coefficient of less than −16 dB and −20 dB has been achieved over a ratio bandwidth of 2.13:1 and 1.62:1, respectively.
This Communication presents a computational design approach for a broadband in-line coaxial-to-rectangular waveguide transition having a 2.83:1 bandwidth. Existing designs have a bandwidth ranging from 1.36:1 to 2:1. The proposed transition consists of a four-step ridge transformer and three sections of the rectangular waveguide. The proposed design approach extends the bandwidth of the transition by a theory-based design of the width and height of the three-section waveguides and by a computer-aided optimization of the stepped-ridge transformer. The dimensions of the three waveguide sections are determined such that the transition operates from very close to the TE10-mode cutoff to slightly less than the TE30-mode cutoff. A four-step ridge transformer was computer-optimized for a low reflection coefficient over a broad bandwidth. The proposed design approach was applied to the design of a coaxial-to-WR75 transition whose reflection coefficient is less than −22.6 dB at 8.14–23.00 GHz (2.83:1 bandwidth). The dimensions of the proposed transition were obtained using an electromagnetic simulation tool. The increased bandwidth of the transition can be very useful, especially in measurement applications.
28 February 2023 in The Journal of Korean Institute of Information Technology
본 논문에서는 전파고도계 개발에 사용하기 위해 여러 가지 평탄면에서의 산란계수 측정결과를 제시하였다. 2x4 배열로 구성된 송신(Tx) 안테나와 수신(Rx) 안테나를 설계 제작하여 산란계수 측정에 사용하였다. 84cm 간격으로 배치된 Tx/Rx 안테나의 Tx 신호가 반사면에 입사된 후 Rx 안테나에서 수신되는 신호의 전력비를 회로망분석기로 측정하였다. 측정된 송수신 전력비를 레이더 방정식에 대입하여 평탄면의 산란계수를 산출하였다. 수직입사, 수평편파 45° 경사입사, 수직편파 45° 경사 입사인 경우의 산란계수를 측정하였다. 수직입사의 경우 산란계수는 반사면의 종류에 따라 0.38부터 7.33의 값을 가지며 45° 경사입사의 경우에는 산란계수가 이보다 훨씬 작은 값을 가짐을 확인하였다.