High-étendue Fourier transform imaging spectrometers can be useful tools for acquiring airborne hyperspectral images, since they do not need moving parts and, as Fourier transform spectrometers, they benefit from the Felgett advantage. The Sagnac interferometer and the Michelson interferometer with dihedrons can be used in such an instrument. These two interferometers act very similarly on the entering beam, and in particular they both work with fringes of equal inclination. This property enables them to benefit from the Jacquinot advantage, too. Nevertheless, to fully benefit from this advantage, it is necessary to maximize the geometrical étendue accepted by the interferometer. From this point of view, the Michelson interferometer with dihedrons appears to be much more interesting than the Sagnac interferometer. Indeed, calculation shows that, in the optimal symmetric configuration, and for the same beamsplitter diameter, the étendue accepted without vignetting by the Michelson interferometer is more than five times greater than the étendue accepted by the Sagnac interferometer. Even if, in a real instrument, the optical scheme cannot be exactly this optimal configuration, this result is a strong argument in support of the Michelson interfero-meter with dihedrons.
19 May 2010 in Journal of the Optical Society of America A
In this article, we report that usual multilayer mirror configurations to focus attosecond pulses generate geometric aberrations and can significantly stretch pulses. The numerical simulations show that the effects can be strong enough to delay some parts of the pulses of an attosecond pulse train and make them interfere with the next pulses of the train. The influence of the numerical aperture on the pulse duration is also studied, showing that such effects can occur even with very low numerical apertures.
25 September 2007 in Journal of the Optical Society of America A
Tolerance in angles of continuously self-imaging gratings (CSIGs) is explored. The degradation in angle of the shape of the point-spread function is theoretically investigated and illustrated by simulations and experiments. The formalism presented is inspired by the one used for classical lenses and can be easily generalized to diffraction gratings. It turns out that well-designed CSIGs could be used for scanning optical systems requiring a large field of view.
An optoelectronic device for generating random numbers at high flow rates is presented. Such a device can be exploited for implementating massive arrays of stochastic decision-making elements encountered in simulated annealing and in Boltzmann machine algorithms. It is comprised of an optical random number generator and an array of electronic neuron elements. The random number arrays are derived from the continually changing modal noise of a step-index optical fiber, and the neuron elements include photodiodes and a few associated electronic components. To demonstrate the feasibility of large arrays of neuron elements, a circuit with three neurons has been implemented and tested. The results reveal that 104 neuron elements can be integrated into 1 cm2 and that flow rates of 1010 random numbers per second are possible.
Imaging static Fourier transform spectrometers are well-adapted instruments for remote sensing. However, the path from the raw images to the spectral images is quite long, thus multiplying the potential noise sources. In this article, we propose to review these perturbation sources. We first recall how detector or photon noise on the interferogram affects the estimated spectrum. Then, we focus on inhomogeneities of the focal plane array. Although these inhomogeneities are deterministic, they generate noise when they are ill-corrected. Finally, we describe defects due to errors that may occur during the image processing step. We also give some avenues to limit the impact of these noises.