Batisse Cindy

Dr. Batisse Cindy

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 June 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
BCBatisse Cindy
Batisse Cindy
ENEmmanuel Nicolas
Emmanuel Nicolas
At present, complete dentures (CDs) remain the only treatment available for the majority of edentulous patients. CDs are primarily fabricated using a conventional method using polymethylmethacrylate (PMMA) resin. The steps involved in PMMA polymerisation directly affect the quality of the resin prosthetic base and any error reduces retention and occlusal accuracy of CDs. Furthermore, when using the conventional technique, the residual monomer alters the resin mechanical properties and may cause mucosal reactions. Recently, computer aided design and computer aided manufacture (CAD/CAM) techniques were increasingly used to fabricate CDs by machining resin discs that have been manufactured under high pressure and temperature. This systematic review compares CAD/CAM and conventional CDs according to their mechanical, physical and chemical characteristics, as well as the clinical impact of any differences between them. A review was conducted according to the preferred reporting items for systematic reviews and meta-analyses checklist on 392 publications from both PubMed and backward research. Fifteen studies have been included. Results showed that CAD/CAM resins had globally better physical and mechanical properties than conventional resins. The use of machined resin could improve the clinical performance, maintenance and longevity of CDs. Further studies in clinical use would be required to complement these results.

20 December 2017 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
GBGuillaume Bonnet
Guillaume Bonnet
BCBatisse Cindy
Batisse Cindy
MBMarion Bessadet
Marion Bessadet
ENEmmanuel Nicolas
Emmanuel Nicolas
JVJean-Luc Veyrune
Jean-Luc Veyrune
Historically, the complete removable denture is the last prosthetic procedure to switch to digital techniques whose advantages are mainly observed in the laboratory stages; however, it is not possible to measure the depressibility of the oral mucosa using optical cameras, thus conventional impression techniques are still necessary. This article describes the clinical and laboratory procedure and practitioners appraisal of the first fifteen digitally designed complete removable dental prostheses. Several systems are now available including the Wieland® Digital Denture® which offers a complete procedure. This system is composed of a five axis-milling machine combined with a laboratory scanner and a design software application. Fifteen rehabilitations were carried out using the Wieland® system. The practitioner’s role is simplified by intraoral recording with a central point and a reduced number of sessions. The prosthesis laboratory requires considerable investment in learning and equipment, making it possible to obtain ideal mounting assemblies in accordance with the occluso-prosthetic concept of bilateral balanced occlusion. The absence of polymerization and therefore of base deformation risks reduce the equilibration step. Finally, the creation of templates as an alternative to the assembly of teeth on wax makes it possible to functionally validate (masticatory and phonatory) the future dentures. However, this procedure still presented some limitations in terms of scanning and software scope of applications. Digital denture design software is relatively efficient and helps to standardize clinical results. However, to this date, improvements of the software are still required for a routine use.

2 February 2024 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Open access
LTLouise Le Texier
Louise Le Texier
ENEmmanuel Nicolas
Emmanuel Nicolas
BCBatisse Cindy
Batisse Cindy
Technological advances in digital acquisition tools have increased the scope of intraoral scanners (IOSs), including scanning a removable complete denture (RCD) to replicate it. However, studies assessing the accuracy of IOSs for replicating a maxillary or mandibular RCD are lacking. The purpose of this in vitro study was to evaluate the accuracy (trueness and precision) of 3 IOSs while replicating a maxillary and mandibular RCD. One maxillary and 1 mandibular RCD were scanned with a desktop scanner (D2000) to obtain the reference model. Two operators scanned each RCD 5 times with 3 different IOSs (TRIOS 4, Primescan, and IS3800), following a predefined acquisition protocol. The 60 study models obtained were compared with the reference model using the Geomagic software program. For each comparison, the mean and standard deviation of discrepancy were calculated. Distances were measured on both the reference and the study model, and differences were calculated to assess whether sagittal or transverse deformations were present. The tolerance percentage of the volume of the digital model compared with the volume of the reference model was determined (difference tolerance was set at 0.1 mm). A univariate analysis of variance followed by a post hoc analysis using the Student-Newman-Keuls (α=.05) test was performed to determine the truest and the most precise IOS. The TRIOS 4 and Primescan IOSs had comparable trueness, with mean dimensional variations of 47 ±27 µm and 57 ±8 µm respectively compared with the reference model. The IS3800 had a lower trueness (98 ±35 µm). Primescan was significantly more precise with a mean standard deviation of 64 ±15 µm (P<.05). The TRIOS 4 (141 ±48 µm) and IS3800 (129 ±24 µm) had comparable precision. Primescan showed the least sagittal and transverse deformation. This study determined that an RCD can be replicated using an IOS, although all IOSs did not have equal accuracy. An in vivo study needs to assess whether this procedure is clinically acceptable.

19 October 2017 in Materials
Verified
Journal Article
Open access
PDF file
BCBatisse Cindy
Batisse Cindy
GBGuillaume Bonnet
Guillaume Bonnet
JVJean-Luc Veyrune
Jean-Luc Veyrune
ENEmmanuel Nicolas
Emmanuel Nicolas
MBMarion Bessadet
Marion Bessadet
The frequent instability of mandibular removable complete dentures affects patient Oral Health Related Quality of Life (OHRQoL). An innovative therapeutic strategy used to improve stability involves placing four symphyseal mini-implants. This study was aimed at assessing OHRQoL over time in subjects in which mini-implants were placed and exploring if certain parameters could predict the evolution of their OHRQoL. The OHRQoL of subjects with dentures was assessed using the Geriatric Oral Health Assessment Index (GOHAI) before (T0), 2–6 months (T1), twelve months (T2) and twenty-four or more months (T3) after mini-implant setting. Age, gender and chewing ability were tested as explanatory variables for the change in OHRQoL with time. Thirteen women and six men were included (mean age: 69 ± 10 years). After treatment, mean GOHAI scores at T1, T2 and T3 increased significantly (p < 0.001). The GOHAI-Add mean score was not affected by age or gender. Baseline chewing ability impacted the “functional” and “pain and discomfort” fields of the mean GOHAI scores (p < 0.05). The OHRQoL quickly improved after mini-implant placement in complete denture wearers and then stabilized over time. Baseline chewing ability can be used as a predictive parameter of OHRQoL.

5 March 2022 in Healthcare
Verified
Journal Article
Open access
PDF file
BCBatisse Cindy
Batisse Cindy
PCPierre-Yves Cousson
Pierre-Yves Cousson
ENEmmanuel Nicolas
Emmanuel Nicolas
MBMarion Bessadet
Marion Bessadet
This case report presents the treatment of a 33-year-old patient with a genetic, generalized microdontia of permanent teeth. Microdontia is a developmental dental anomaly of the teeth characterized by a decrease in their size. In the literature, treatment has been multidisciplinary, often utilizing orthodontics and implantology. However, for adult patients with generalized microdontia who do not benefit from these treatments as much, a combination of adhesive dentistry, endodontics and removable prostheses remains a therapeutic alternative to consider. Given the specificities of the patient and the nature of the care, the objective of this treatment option was to manage the patient’s comfort while guaranteeing quality of care. A feature of this treatment was the use of general anesthesia for endodontic treatments and exodontia. Chairside CAD/CAM and adhesive dentistry reduced the chairside time and preserved healthy dental tissue.

1 December 2014
Verified
Journal Article
Closed access
BCBatisse Cindy
Batisse Cindy
MBMarion Bessadet
Marion Bessadet
NDNicolas Decerle
Nicolas Decerle
JVJean-Luc Veyrune
Jean-Luc Veyrune
ENEmmanuel Nicolas
Emmanuel Nicolas