Emerging data suggest that post-traumatic stress disorder (PTSD) arises from disrupted brain default mode network (DMN) activity manifested by dysregulated encephalogram (EEG) alpha oscillations. Hence, we pursued the treatment of combat veterans with PTSD (n = 185) using an expanded form of repetitive transcranial magnetic stimulation (rTMS) termed personalized-rTMS (PrTMS). In this treatment methodology spectral EEG based guidance is used to iteratively optimize symptom resolution via (1) stimulation of multiple motor sensory and frontal cortical sites at reduced power, and (2) adjustments of cortical treatment loci and stimulus frequency during treatment progression based on a proprietary frequency algorithm (PeakLogic, Inc. San Diego) identifying stimulation frequency in the DMN elements of the alpha oscillatory band. Following 4 - 6 weeks of PrTMS® therapy in addition to routine PTSD therapy, veterans exhibited significant clinical improvement accompanied by increased cortical alpha center frequency and alpha oscillatory synchronization. Full resolution of PTSD symptoms was attained in over 50% of patients. These data support DMN involvement in PTSD pathophysiology and suggest a role in therapeutic outcomes. Prospective, sham controlled PrTMS® trials may be warranted to validate our clinical findings and to examine the contribution of DMN targeting for novel preventive, diagnostic, and therapeutic strategies tailored to the unique needs of individual patients with both combat and non-combat PTSD.
Repetitive transcranial magnetic stimulation (rTMS) is a rapidly developing therapeutic modality for the safe and effective treatment of neuropsychiatric disorders. However, clinical rTMS driving systems and head coils are large, heavy, and expensive, so miniaturized, affordable rTMS devices may facilitate treatment access for patients at home, in underserved areas, in field and mobile hospitals, on ships and submarines, and in space. The central component of a portable rTMS system is a miniaturized, lightweight coil. Such a coil, when mated to lightweight driving circuits, must be able to induce B and E fields of sufficient intensity for medical use. This paper newly identifies and validates salient theoretical considerations specific to the dimensional scaling and miniaturization of coil geometries, particularly figure-8 coils, and delineates novel, key design criteria. In this context, the essential requirement of matching coil inductance with the characteristic resistance of the driver switches is highlighted. Computer simulations predicted E- and B-fields which were validated via benchtop experiments. Using a miniaturized coil with dimensions of 76 mm × 38 mm and weighing only 12.6 g, the peak E-field was 87 V/m at a distance of 1.5 cm. Practical considerations limited the maximum voltage and current to 350 V and 3.1 kA, respectively; nonetheless, this peak E-field value was well within the intensity range, 60–120 V/m, generally held to be therapeutically relevant. The presented parameters and results delineate coil and circuit guidelines for a future miniaturized, power-scalable rTMS system able to generate pulsed E-fields of sufficient amplitude for potential clinical use.
30 June 2023 in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
Pulse stimulation of peripheral nerves (PNS) is extensively used in the diagnosis of nerve abnormalities and can be applied for pain mitigation and to promote nerve regrowth. Nerve stimulation via magnetic pulses can provide advantages over conventional electrical stimulation; it obviates the need for electrode contact with the skin and is typically less painful. This work contributes to the development of compact and portable systems for magnetic PNS (M-PNS). To date, M-PNS has largely employed pulse generation systems developed for repetitive transcranial magnetic stimulation (rTMS). A new circuit is demonstrated to generate pulsed magnetic fields that increases induced electric (E) field intensities over those attainable in conventional rTMS systems. The resultant E-field has a shortened duration. The required external voltage input is below 300 V. A compact circuit implementation produced peak E-fields of 280 V/m at 1.5 cm distance from the magnetic coil, in 23 μs pulses (while 70-280 μs pulses are typically used for rTMS). Although threshold E fields for neural excitation increase with shorter pulse widths, neural excitation is demonstrated in human subjects via ulnar nerve stimulation and electromyography. This circuit technique may facilitate greater feasibility and flexibility in the design of miniaturized and portable PNS medical devices.