Leonard A Temme

Dr. Leonard A Temme

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 November 2023 in Biology
Verified
Journal Article
Open access
PDF file
LTLeonard A Temme
Leonard A Temme
HWHarrison L. Wittels
Harrison L. Wittels
MWMichael Wishon
Michael Wishon
POPaul St. Onge
Paul St. Onge
SMSamantha McDonald
Samantha McDonald
SWS. Wittels
S. Wittels
Military aviators endure high cognitive loads and hypoxic environments during flight operations, impacting the autonomic nervous system (ANS). The synergistic effects of these exposures on the ANS, however, are less clear. This study investigated the simultaneous effects of mild hypoxia and high cognitive load on the ANS in military personnel. This study employed a two-factor experimental design. Twenty-four healthy participants aged between 19 and 45 years were exposed to mild hypoxia (14.0% O2), normoxia (21.0% O2), and hyperoxia (33.0% O2). During each epoch (n = 5), participants continuously performed one 15 min and one 10 min series of simulated, in-flight tasks separated by 1 min of rest. Exposure sequences (hypoxia–normoxia and normoxia–hyperoxia) were separated by a 60 min break. Heart rate (HR), heart rate variability (HRV), and O2 saturation (SpO2) were continuously measured via an armband monitor (Warfighter MonitorTM, Tiger Tech Solutions, Inc., Miami, FL, USA). Paired and independent t-tests were used to evaluate differences in HR, HRV, and SpO2 within and between exposure sequences. Survival analyses were performed to assess the timing and magnitude of the ANS responses. Sympathetic nervous system (SNS) activity during hypoxia was highest in epoch 1 (HR: +6.9 bpm, p = 0.002; rMSSD: −9.7 ms, p = 0.003; SDNN: −11.3 ms, p = 0.003; SpO2: −8.4%, p < 0.0000) and appeared to slightly decline with non-significant increases in HRV. During normoxia, SNS activity was heightened, albeit non-significantly, in epoch 1, with higher HR (68.5 bpm vs. 73.0 bpm, p = 0.06), lower HRV (rMSSD: 45.1 ms vs. 38.7 ms, p = 0.09 and SDNN: 52.5 ms vs. 45.1 ms, p = 0.08), and lower SpO2 (−0.7% p = 0.05). In epochs 2–4, HR, HRV, and SpO2 trended towards baseline values. Significant between-group differences in HR, HRV, and O2 saturation were observed. Hypoxia elicited significantly greater HRs (+5.0, p = 0.03), lower rMSSD (−7.1, p = 0.03), lower SDNN (−8.2, p = 0.03), and lower SpO2 (−1.4%, p = 0.002) compared to normoxia. Hyperoxia appeared to augment the parasympathetic reactivation reflected by significantly lower HR, in addition to higher HRV and O2 relative to normoxia. Hypoxia induced a greater ANS response in military personnel during the simultaneous exposure to high cognitive load. The significant and differential ANS responses to varying O2 levels and high cognitive load observed highlight the importance of continuously monitoring multiple physiological parameters during flight operations.

14 May 2024 in Biology
Verified
Journal Article
Open access
PDF file
HWHarrison L. Wittels
Harrison L. Wittels
SWS. Wittels
S. Wittels
MWMichael Wishon
Michael Wishon
JVJonathan Vogl
Jonathan Vogl
POPaul St. Onge
Paul St. Onge
LTLeonard A Temme
Leonard A Temme
Executing flight operations demand that military personnel continuously perform tasks that utilize low- and high-order cognitive functions. The autonomic nervous system (ANS) is crucial for regulating the supply of oxygen (O2) to the brain, but it is unclear how sustained cognitive loads of different complexities may affect this regulation. Therefore, in the current study, ANS responses to low and high cognitive loads in hypoxic and normoxic conditions were evaluated. The present analysis used data from a previously conducted, two-factor experimental design. Healthy subjects (n = 24) aged 19 to 45 years and located near Fort Novosel, AL, participated in the parent study. Over two, 2-h trials, subjects were exposed to hypoxic (14.0% O2) and normoxic (21.0% O2) air while simultaneously performing one, 15-min and one, 10-min simulation incorporating low- and high-cognitive aviation-related tasks, respectively. The tests were alternated across five, 27-min epochs; however, only epochs 2 through 4 were used in the analyses. Heart rate (HR), HR variability (HRV), and arterial O2 saturation were continuously measured using the Warfighter MonitorTM (Tiger Tech Solutions, Inc., Miami, FL, USA), a previously validated armband device equipped with electrocardiographic and pulse oximetry capabilities. Analysis of variance (ANOVA) regression models were performed to compare ANS responses between the low- and high-cognitive-load assessments under hypoxic and normoxic conditions. Pairwise comparisons corrected for familywise error were performed using Tukey’s test within and between high and low cognitive loads under each environmental condition. Across epochs 2 through 4, in both the hypoxic condition and the normoxic condition, the high-cognitive-load assessment (MATB-II) elicited heightened ANS activity, reflected by increased HR (+2.4 ± 6.9 bpm) and decreased HRV (−rMSSD: −0.4 ± 2.7 ms and SDNN: −13.6 ± 14.6 ms). Conversely, low cognitive load (ADVT) induced an improvement in ANS activity, with reduced HR (−2.6 ± 6.3 bpm) and increased HRV (rMSSD: +1.8 ± 6.0 ms and SDNN: vs. +0.7 ± 6.3 ms). Similar observations were found for the normoxic condition, albeit to a lower degree. These within-group ANS responses were significantly different between high and low cognitive loads (HR: +5.0 bpm, 95% CI: 2.1, 7.9, p < 0.0001; rMSSD: −2.2 ms, 95% CI: −4.2, −0.2, p = 0.03; SDNN: −14.3 ms, 95% CI: −18.4, −10.1, p < 0.0001) under the hypoxic condition. For normoxia, significant differences in ANS response were only observed for HR (+4.3 bpm, 95% CI: 1.2, 7.4, p = 0.002). Lastly, only high cognitive loads elicited significant differences between hypoxic and normoxic conditions but just for SDNN (−13.3 ms, 95% CI, −17.5, −8.9, p < 0.0001). Our study observations suggest that compared to low cognitive loads, performing high-cognitive-load tasks significantly alters ANS activity, especially under hypoxic conditions. Accounting for this response is critical, as military personnel during flight operations sustain exposure to high cognitive loads of unpredictable duration and frequency. Additionally, this is likely compounded by the increased ANS activity consequent to pre-flight activities and anticipation of combat-related outcomes.

31 March 2025 in Research Square
Verified
Preprint
Open access
PDF file
LTLeonard A Temme
Leonard A Temme
JVJon Vogl
Jon Vogl
KOKevin O’bRien
Kevin O’bRien
CMCharles McCurry
Charles McCurry
POPaul St. Onge
Paul St. Onge
Background: Cognitive workload (CWL), a crucial concept in aviation human factors, has been described as the interplay between the aviator’s multidimensional, limited cognitive resources and the simultaneous dynamic task demands. The literature reports three general approaches to measuring CWL, task performance metrics, psychophysiological biomarkers, and relatively standardized CWL self-report ratings. The present study assesses a fourth method adapted from standard classic sensory psychophysics. Methods: Subjects were three study-team members highly trained on a surrogate aviation task. Random sequences of 10 CWL task demand levels (DL) spanning the range from low to high were presented to each subject. Using a 2-alternative forced-choice (2AFC) psychophysical thresholding paradigm, the minimum difference in DL a subject could reliably discriminate was measured at each DL. This method of measuring CWL DL differences is analogous to a psychophysical measurement of just noticeable sensory differences (JND). Results: Unexpectedly, the JND size for high-to-low DL transitions was much smaller than that of low-to-high DL transitions. Conclusions: The study demonstrated the feasibility of adapting a quantitative sensory psychophysical testing paradigm to develop an analogous psychophysics of CWL. The results identified an unexpected difference in CWL JND size that depends on the direction of transition. This difference suggests that the CWL demand experienced at a given demand level may depend on whether the demand level was approached from a lower or higher direction. This difference may have practical implications for implementing dynamic adaptive automation. These results support the value of further studies to elaborate the concept of a CWL psychophysics.

19 August 2024 in Military Medicine
Verified
Journal Article
Open access
PDF file
LTLeonard A Temme
Leonard A Temme
RNRyan Nagy
Ryan Nagy
IPIsaiah Persson
Isaiah Persson
Introduction: Vection is a stationary individual’s illusory experience of self-motion. This illusory self-motion is operationally important for aviation, particularly military aviation, since vection is a dramatic example of spatial disorientation (SD), which is an individual’s failure to correctly sense the aircraft’s position, motion, and/or attitude with respect to the fixed coordinate system of the Earth’s surface and its gravitational vertical. Notably, SD is a major cause of fatal aviation mishaps, and the visual system is particularly prone to provoking vection. This article describes the Virtual Reality Vection System (VRVS), which uses computer-controlled virtual reality technology to induce vection under controlled conditions for training, demonstration, testing, and research. Materials and Methods: The VRVS enables the precise specification of the number and appearance of visual stimulus elements intended to generate vection, including photorealistic images. The VRVS can present visual stimuli on any OpenXR-capable virtual reality headset. The VRVS currently records 2 types of behavioral responses, button presses to indicate the presence and duration of vection and the voltage of a handheld linear potentiometer to indicate the presence, duration, and magnitude of vection. Results: An approved test plan helped guide, organize, document, and validate the VRVS during its development. Under this plan, a pair of tests guided hardware and software development of the VRVS system. Although the first test verified the ability of the VRVS to generate and measure vection, it also demonstrated that the VRVS can quickly manipulate the visual stimuli from one trial to the next so that the VRVS can support complex experimental designs. The second test used these capabilities to verify that the VRVS can characterize vection in a more analytic fashion using a masking paradigm. Specifically, the test assessed whether random stimulus elements injected into the vection-inducing stimulus disrupted vection in a quantifiable fashion. This work opens the door to studies that characterize the necessary and sufficient visual elements for vection-based SD. Discussion: The VRVS is currently used to research, develop, test, and evaluate mitigation strategies targeting vection-related SD in degraded visual environments. Similarly, the VRVS is supporting research to develop methods to predict individual differences in visually induced motion sickness susceptibilities. The VRVS is currently being integrated with a precision motor-controlled rotating Barany chair for multisensory studies. It should be noted that since the VRVS was developed to support United States Army Aeromedical Research Laboratory projects, it is an Army product representing government intellectual property and may be freely available to other government institutions.

5 May 2006
Verified
Conference Paper
Closed access
PDF file
LTLeonard A Temme
Leonard A Temme
DSDavid L Still
David L Still
AHAdrianus J M Houtsma
Adrianus J M Houtsma
Background: Since helmet mounted displays (HMDs) are slaved to a pilot's head, head motion is important for the design of HMDs and their symbology. This is particularly true since the lateral tilt of a pilot's head changes when the pilot shifts his/her gaze from the horizon visible outside the cockpit to the instruments inside the cockpit. This change in head tilt, which may contribute to episodes of spatial disorientation and possibly dangerous control input reversal errors, is commonly attributed to a neuro-muscular reflex driven by the apparent tilt of the visible horizon, the so-called optokinetic cervical reflex (OKCR). The present paper: (1) describes head motion in the frequency domain, and (2) elaborates a biomechanical explanation for the observed head tilt that is simpler than the neurological OKCR model. Methods: Fourier spectral decompositions were calculated from archived head pitch, tilt, and azimuth data recorded at 10 Hz from four pilots as they executed a slalom maneuver in an AH Mk 7 Linx helicopter. Pilots A through D performed the slalom 11, 12, 8, and 11 times, respectively, for a total of 42 flights. Results: The Fourier decomposition showed that the typical azimuth spectrum differs from that of pitch, and tilt. Discussion: These results provide: (1) spectral descriptions of head azimuth, pitch, and tilt to aid the design of HMD systems, and (2) further support for the biomechanical model of head tilt.

3 April 2008
Verified
Conference Paper
Closed access
PDF file
DSDavid L Still
David L Still
LTLeonard A Temme
Leonard A Temme
Hover is an essential component of rotary wing aviation but learning to hover is extremely difficult. From the viewpoint inside the cockpit, the beginning student neither sees nor understands what needs to be done to control the aircraft. This is because the out-the-window real world visual cues suffer from two primary shortcomings. First, the real world visual cues are ambiguous. For example, the relative motion of the ground moving under the nose may indicate forward flight, pitching upward, vertical ascent, or any combination of these. Second, human ability to judge aircraft pitch by itself is insufficient to stabilize the aircraft; such other clues as relative motion or parallax are needed to augment pitch judgments to set aircraft attitude adequately. We report a training display (TD) designed to assist training rotary wing hover. The TD is specifically constructed to communicate aircraft performance and attitude to the student pilot and to disambiguate the external world's features and motions cues into symbology that allows each cue independently to support sufficient levels of parameter resolution. Our preliminary observations, based on pilot data collected during the design, parameterization, and calibration of the TD indicate that it meets its goals in a fashion that enables beginning flight students to understand and interpret the motion cues of the real world out-the-window view.