Mehmet Azmi AKTACİR

Prof. Mehmet Azmi AKTACİR

Mechanical Engineering department, Harran University, Sanliurfa, Turkey (Türkiye)
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 December 2023 in Ceramics International
Verified
Journal Article
Closed access
EAE. Aslan
E. Aslan
ÖEÖ. Emir
Ö. Emir
FAF. Arslan
F. Arslan
AGA. Goktas
A. Goktas
ATA. Tumbul
A. Tumbul
FAF. Aslan
F. Aslan

1 March 2011 in Applied Energy
Verified
Journal Article
Closed access
HBHüsamettin Bulut
Hüsamettin Bulut
MAMehmet Azmi AKTACİR
Mehmet Azmi AKTACİR

1 June 2006 in Applied Energy
Verified
Journal Article
Closed access
MAMehmet Azmi AKTACİR
Mehmet Azmi AKTACİR
OBOrhan Büyükalaca
Orhan Büyükalaca
TYTuncay Yılmaz
Tuncay Yılmaz

1 June 2008 in Energy Conversion and Management
Verified
Journal Article
Closed access
MAMehmet Azmi AKTACİR
Mehmet Azmi AKTACİR
OBOrhan Büyükalaca
Orhan Büyükalaca
HBHüsamettin Bulut
Hüsamettin Bulut
TYTuncay YILMAZ
Tuncay YILMAZ

1 March 2009 in Applied Thermal Engineering
Verified
Journal Article
Closed access
BYBulent Yeşilata
Bulent Yeşilata
MAMehmet Azmi AKTACİR
Mehmet Azmi AKTACİR

17 November 2021 in Mathematics
Verified
Journal Article
Open access
PDF file
RARami Alamoudi
Rami Alamoudi
OTOsman Taylan
Osman Taylan
MAMehmet Azmi AKTACİR
Mehmet Azmi AKTACİR
Enrique Herrera-ViedmaEnrique Herrera-Viedma
Enrique Herrera-Viedma
One of the most favorable renewable energy sources, solar photovoltaic (PV) can meet the electricity demand considerably. Sunlight is converted into electricity by the solar PV systems using cells containing semiconductor materials. A PV system is designed to meet the energy needs of King Abdulaziz University Hospital. A new method has been introduced to find optimal working capacity, and determine the self-consumption and sufficiency rates of the PV system. Response surface methodology (RSM) is used for determining the optimal working conditions of PV panels. Similarly, an adaptive neural network based fuzzy inference system (ANFIS) was employed to analyze the performance of solar PV panels. The outcomes of methods were compared to the actual outcomes available for testing the performance of models. Hence, for a 40 MW target PV system capacity, the RSM determined that approximately 33.96 MW electricity can be produced, when the radiation rate is 896.3 W/m2, the module surface temperature is 41.4 °C, the outdoor temperature is 36.2 °C, the wind direction and speed are 305.6 and 6.7 m/s, respectively. The ANFIS model (with nine rules) gave the highest performance with lowest residual for the same design parameters. Hence, it was determined that the hourly electrical energy requirement of the hospital can be met by the PV system during the year.