Background: The present article describes a step-by-step maximally digitalized workflow protocol with computer-aided design and computer-aided manufacturing (CAD/CAM) in partial-arch edentulous patients rehabilitated with fixed dental prostheses and removable partial dentures (FDPs and RPDs). Methods: Facial digitalization, intraoral scans, and functional mandibular movement recordings were used to create a 4D virtual patient on commercially available CAD software. The fixed components including post-and-cores, both metal–ceramic with extra-coronal attachment and monolithic zirconia crowns, and the RPDs were manufactured by computer numerical controlled direct milling. Results: This innovative digital approach using the virtual patient and the superimposition of interim RPDs fitted in the mouth has been used to provide fixed and removable rehabilitation to the patient without clinical complications with 2 years of follow-up. Conclusions: Within the limitations of this report, the developed combined prosthesis fabrication technique allowed optimization of the production by decreasing the clinical steps and laboratory procedures in partial-arch edentulous rehabilitated with FDPs and RPDs.
The development of new titanium alloys for dental implants aims to eliminate potentially cytotoxic elements while achieving mechanical properties compatible with bone, particularly a low elastic modulus. This study evaluates the in vitro biocompatibility and mechanical performance of a newly developed β-type Ti-20Zr-3Mo-3Sn (Ti2033) alloy, in comparison with Ti-14Zr and Ti-6Al-4V, two reference alloys used in oral implantology. Mechanical properties were assessed by tensile testing and hardness measurements, while biocompatibility was evaluated using MTT and wound healing assays on osteoblastic cells (Saos-2). Ti2033 exhibits a significantly reduced Young’s modulus (52 GPa), nearly 50% that of the reference alloys, thereby improving mechanical compatibility with bone. Although its ultimate tensile strength (825 MPa) and hardness (300 HV) are slightly lower, Ti2033 shows good ductility (elongation at rupture: 10%). No cytotoxic effects were observed, and cellular viability and migration were comparable among the three alloys. These findings suggest that Ti2033 combines mechanical performance and biocompatibility, making it a promising candidate for endosseous dental implant applications.
31 October 2023 in The Journal of Prosthetic Dentistry
In clinical situations of complete rehabilitation with fixed prostheses, mastering each parameter of all restorations (shape, marginal adaptation, proximal and occlusal contacts) proves to be a challenge. The large number of restorations involves many potential adjustments that are time‐consuming and lead to final ceramic properties degradation. This clinical report highlights the benefits of using castable patterns in complete fixed prosthetic rehabilitation. Minimal preparations of the teeth were carried out using the conventional mock‐up technique. The impressions were then digitized to produce wax and resin patterns (Castable Wax Resin; Formlabs) with a stereolithography 3D printer (Form 2; Formlabs). During oral try‐in of patterns, adjustments can be carried out to correct any defects of shape, marginal adaptation, proximal, and occlusal contacts. The definitive restorations were directly pressed from the patterns into lithium disilicate glass‐reinforced ceramic (IPS e.max Press; Ivoclar Vivadent) using the lost‐wax casting process. Finally, the restorations were placed permanently in the mouth with complete patient satisfaction after 4 years of follow‐up. This procedure is intended to reduce ceramic adjustments on definitive restorations. It is especially relevant in complete fixed rehabilitation and in situations where the thickness of ceramic restorations does not allow for try‐in before bonding.
29 November 2025 in The Journal of Prosthetic Dentistry