Many efforts have been presented in the bibliography for wind power forecasting in power systems and few of them have been used for autonomous power systems. The impact of knowing the distribution function of wind power forecasting error in the economic operation of a power system is studied in this paper. The papers proposes that the distribution of the wind power forecasting error of a specific tool can be easily derived if, for that model, an evaluation of its performance is made off-line comparing the forecasted values of the tool with the actual wind power values in the same horizon. The proposed methodology is applied to the autonomous power system of Crete. It is shown that the improvement of the performance of wind power forecasting tool has significant economic impact on the operation of autonomous power systems with increased wind power penetration. The obtained results for various levels of wind power production and load show that using only mean absolute percentage error (MAPE) leads to significant change in the estimation of the wind power to be shed to avoid technical limits violation, especially if the wind power forecasting tool presents underestimation of the actual production
This paper compares two common dispatch policies—Load-Following (LF) and Cycle-Charging (CC)—for a photovoltaic Battery Energy Storage System (PV–BESS) microgrid (MG) with a 12 kW diesel generator, using a full-year of real 15 min PV and load data from an industrial use case in Germany. A forward time-step simulation enforces the battery State-of-Energy (SoE) window (total basis [20, 100] %, DoD = 80%) and computes curtailment, generator use, and unmet energy. Feasible designs satisfy a Loss of Power Supply Probability (LPSP) ≤ 0.03. Economic evaluation follows an Equivalent Annual Cost (EUAC) model with PV and BESS Capital Expenditure/Operation and Maintenance (CAPEX/O&M) (cycle life dependent on DoD and 15-year calendar life), generator costs, and fuel via SFC and diesel price. A value of lost load (VOLL) can be applied to unserved energy, with an optional curtailment penalty. Across the design space, a clear cost valley appears toward moderate storage and modest PV, with the baseline optimum at ≈56 kWp PV and 200 kWh BESS (DoD = 80%). Both policies meet the reliability target (in our runs LPSP ≈ 0), and their SoE trajectories are nearly identical; CC only lifts the SoE slightly after generator-ON events by using headroom to charge, while LF supplies just the residual deficit. Sensitivity analyses show that the optimum is most affected by diesel price and discount rate, with smaller shifts for ±10% changes in SFC. The study provides a transparent, reproducible workflow—grounded in real data—for controller selection and capacity planning.
16 May 2017 in Advances in Building Energy Research