Pleural effusion (PLEFF), mostly caused by volume overload, congestive heart failure, and pleuropulmonary infection, is a common condition in critical care patients. Thoracic ultrasound (TUS) helps clinicians not only to visualize pleural effusion, but also to distinguish between the different types. Furthermore, TUS is essential during thoracentesis and chest tube drainage as it increases safety and decreases life-threatening complications. It is crucial not only during needle or tube drainage insertion, but also to monitor the volume of the drained PLEFF. Moreover, TUS can help diagnose co-existing lung diseases, often with a higher specificity and sensitivity than chest radiography and without the need for X-ray exposure. We review data regarding the diagnosis and management of pleural effusion, paying particular attention to the impact of ultrasound. Technical data concerning thoracentesis and chest tube drainage are also provided.
15 June 2016 in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
Automated systems can improve the stability of controlled variables and reduce the workload in clinical practice without increasing the risks to patients. We conducted this review and meta-analysis to assess the clinical performance of closed-loop systems compared with manual control. Our primary outcome was the accuracy of closed-loop systems in comparison with manual control to maintain a given variable in a desired target range. The occurrence of overshoot and undershoot episodes was the secondary outcome. We retrieved randomized controlled trials on accuracy and safety of closed-loop systems versus manual control. Our primary outcome was the percentage of time during which the system was able to maintain a given variable (eg, bispectral index or oxygen saturation) in a desired range or the proportion of the target measurements that was within the required range. Our secondary outcome was the percentage of time or the number of episodes that the controlled variable was above or below the target range. The standardized mean difference and 95% confidence interval (CI) were calculated for continuous outcomes, whereas the odds ratio and 95% CI were estimated for dichotomous outcomes. Thirty-six trials were included. Compared with manual control, automated systems allowed better maintenance of the controlled variable in the anesthesia drug delivery setting (95% CI, 11.7%–23.1%; percentage of time,P< 0.0001, number of studies:n= 15), in patients with diabetes mellitus (95% CI, 11.5%–30.9%; percentage of time,P= 0.001,n= 8), and in patients mechanically ventilated (95% CI, 1.5%–23.1%; percentage of time,P= 0.03,n= 8). Heterogeneity among the studies was high (>75%). We observed a significant reduction of episodes of overshooting and undershooting when closed-loop systems were used. The use of automated systems can result in better control of a given target within a selected range. There was a decrease of overshooting or undershooting of a given target with closed-loop systems.
Lung ultrasound can be used as an alternative to chest radiography (CXR) for the diagnosis and follow-up of various lung diseases in the intensive care unit (ICU). Our aim was to evaluate the influence that introducing a routine daily use of lung ultrasound in critically ill patients may have on the number of CXRs and as a consequence, on medical costs and radiation exposure. Data were collected by conducting a retrospective evaluation of the medical records of adult patients who needed thoracic imaging and were admitted to our academic polyvalent ICU. We compared the number of CXRs and relative costs before and after the introduction of lung ultrasound in our ICU. A total of 4134 medical records were collected from January 2010 to December 2014. We divided our population into two groups, before (Group A, 1869 patients) and after (Group B, 2265 patients) the introduction of a routine use of LUS in July 2012. Group A performed a higher number of CXRs compared to Group B (1810 vs 961, P = 0.012), at an average of 0.97 vs 0.42 exams per patient. The estimated reduction of costs between Groups A and B obtained after the introduction of LUS, was 57%. No statistically significant difference between the outcome parameters of the two groups was observed. Lung ultrasound was effective in reducing the number of CXRs and relative medical costs and radiation exposure in ICU, without affecting patient outcome.
5 October 2016 in Gynecologic and Obstetric Investigation
Background/Aims: The normal lung ultrasound (US) pattern during a regular pregnancy has not been evaluated extensively in the current literature. Pregnancy-related changes in the respiratory tract affect maternal predisposition to several respiratory complications; consequently, it is important to differentiate between a physiologic pattern during pregnancy and a pathologic lung pattern, due to respiratory failure. The goal of our study was to assess the normal US lung pattern in women without known comorbidities in the last weeks of pregnancy. Methods: We conducted a prospective cross-sectional observational pilot study. Chest wall was examined in 8 areas, 1 scan for each area with women in supine position. Results: One hundred fifty parturients were enrolled during the 36th-38th gestational weeks. None of the participants showed pleural effusion, pneumothorax or lung consolidation. None presented an interstitial syndrome US pattern. One hundred thirteen participants out of 150 (75%) showed A-lines in all the regions. The remaining 25% showed 1 or 2 B-lines in at least 3 regions. Only 2 participants showed 2 positive regions also. Conclusions: We found that, in the majority of the women examined, the lung US pattern matches the physiological pattern in non-pregnant patients. Lung US assessment is a feasible and a helpful diagnostic tool during pregnancy.
This was a single-center, observational, prospective study designed to compare the effectiveness of a real-time, ultrasound- with landmark-guided technique for subclavian vein cannulation. Two groups of 74 consecutive patients each underwent subclavian vein catheterization. One group included patients from intensive care unit, studied by using an ultrasound-guided technique. The other group included patients from surgery or emergency units, studied by using a landmark technique. The primary outcome for comparison between techniques was the success rate of catheterization. Secondary outcomes were the number of attempts, cannulation failure, and mechanical complications. Although there was no difference in total success rate between ultrasound-guided and landmark groups (71 vs. 68, p = 0.464), the ultrasound-guided technique was more frequently successful at first attempt (64 vs. 30, p < 0.001) and required less attempts (1 to 2 vs. 1 to 6, p < 0.001) than landmark technique. Moreover, the ultrasound-guided technique was associated with less complications (2 vs. 13, p < 0.001), interruptions of mechanical ventilation (1 vs. 57, p < 0.001), and post-procedure chest X-ray (43 vs. 62, p = 0.001). In comparison with landmark-guided technique, the use of an ultrasound-guided technique for subclavian catheterization offers advantages in terms of reduced number of attempts and complications.