Awais Shah

Dr. Awais Shah


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 September 2020 in International Journal of Control, Automation, and Systems
Verified
Journal Article
Closed access
PDF file
THTianpeng Huang
Tianpeng Huang
DHDeqing Huang
Deqing Huang
ZWZhikai Wang
Zhikai Wang
XDXi Dai
Xi Dai
ASAwais Shah
Awais Shah

9 November 2017 in Energies
Verified
Journal Article
Open access
PDF file
ASAwais Shah
Awais Shah
DHDeqing Huang
Deqing Huang
YCYixing Chen
Yixing Chen
XKXin Kang
Xin Kang
YCYong Chen
Yong Chen
In order to achieve feasible and copacetic low energy consuming building, a robust and efficient air conditioning system is necessary. Since heating ventilation and air conditioning systems are nonlinear and temperature and humidity are coupled, application of conventional control is inappropriate. A multi-input multi-output nonlinear model is presented. The temperature and humidity of thermal zone are ascendance by the manipulation of the water and air flow rates. A sliding mode controller (SMC) is designed to ensure robust performance of air handling unit in the presence of uncertainties. A simple proportional-integral-derivative (PID) controller is used as a comparison template to highlight the efficiency of the proposed controller. To accomplish tracking targets, a variety of desired temperature and relative humidity commands (including ramp and combination with sequence of steps) are investigated. According to simulation results, SMC transcends the PID controller in terms of settling time, steady state and rise time, which makes SMC more energy efficient.

25 October 2018 in Energies
Verified
Journal Article
Open access
PDF file
ASAwais Shah
Awais Shah
DHDeqing Huang
Deqing Huang
THTianpeng Huang
Tianpeng Huang
UFUmar Farid
Umar Farid
Variable air volume (VAV) is the most common installation among heating ventilating and air conditioning (HVAC) systems. To maintain the comfort level and lessen energy utilization, there is a pressing need for its effective control. In this study, a lumped parameter model composed of multizone VAV is considered, and sliding mode control (SMC) is designed to guarantee robust operation in the presence of uncertainties. For comparison of the proposed controller performance, a proportional integral derivative (PID) controller is additionally designed. The indoor temperature of zones is controlled by positioning the supply air dampers. Tracking objectives of controllers are inspected via two practical cases of desired temperature setpoints including (a) sinusoidal waveform and (b) the combination of steps. Results obtained using SMC ensure the robust operation of the VAV system against parametric uncertainties. In addition, SMC is more energy efficient than PID in terms of overshoot and settling time.