Maria-Alexandra Zolya

Ms. Maria-Alexandra Zolya

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 February 2024 in Sensors
Verified
Journal Article
Open access
PDF file
DBDragoș-Vasile Bratu
Dragoș-Vasile Bratu
MZMaria-Alexandra Zolya
Maria-Alexandra Zolya
SMSorin-Aurel Moraru
Sorin-Aurel Moraru
In the face of today’s ever-evolving global health landscape and ambient assisted living (AAL), marked by the persistent emergence of novel viruses and diseases that impact vulnerable categories and individual safety, the need for innovative disinfection solutions has surged to unprecedented levels. In pursuit of advancing the field of autonomous UV-C disinfection robotics, we conducted two comprehensive state-of-the-art analyses: the first one in the literature and the second one in existing commercial disinfection robots to identify current challenges. Of all of the challenges, we consider the most outstanding ones to be safeguarding humans and animals and understanding the surroundings while operating the disinfection process challenges that we will address in this article. While UV-C lamps have demonstrated their effectiveness in sterilizing air and surfaces, the field of autonomous UV-C disinfection robotics represents a critical domain that requires advancement, particularly in safeguarding the wellbeing of humans and animals during operation. Operating UV-C disinfection robots in close proximity to humans or animals introduces inherent risks, and existing disinfection robots often fall short in incorporating advanced safety systems. In response to these challenges, we propose the RoboCoV Cleaner—an indoor autonomous UV-C disinfection robot equipped with an advanced dual and redundant safety system. This novel approach incorporates multiple passive infrared (PIR) sensors and AI object detection on a 360-degree camera. Under our test, the dual-redundant system reached more than 90% when detecting humans with high accuracy using the AI system 99% up to 30 m away in a university hallway (different light conditions) combined with the PIR system (with lower accuracy). The PIR system was proved to be a redundant system for uninterrupted operation during communication challenges, ensuring continuous sensor information collection with a swift response time of 50 ms (image processing within 200 ms). It empowers the robot to detect and react to human presence, even under challenging conditions, such as when individuals wear masks, in complete darkness, under UV light, or in environments with blurred visual conditions. In our test, the detection system performed outstandingly well with up to 99% detection rate of humans. Beyond safety features, the RoboCoV Cleaner can identify objects in its surroundings. This capability empowers the robot to discern objects affected by UV-C light, enabling it to apply specialized rules for targeted disinfection. The proposed system exhibits a wide range of capabilities beyond its core purpose of disinfection, making it suitable for healthcare facilities, universities, conference venues, and hospitals. Its implementation has the ability to improve significantly human safety and protect people. By showcasing the RoboCoV Cleaner’s safety-first approach and adaptability, we aim to set a new benchmark for UV-C disinfection robots, promoting clean and secure environments while protecting vulnerable people, even in challenging scenarios.

14 January 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
MZMaria-Alexandra Zolya
Maria-Alexandra Zolya
CBCosmin Baltag
Cosmin Baltag
DBDragoș-Vasile Bratu
Dragoș-Vasile Bratu
Simona ComanSimona Coman
Simona Coman
SMSorin-Aurel Moraru
Sorin-Aurel Moraru
The end of 2019 could be mounted in a rudimentary framing of a new medical problem, which globally introduces into the discussion a fulminant outbreak of coronavirus, consequently spreading COVID-19 that conducted long-lived and persistent repercussions. Hence, the theme proposed to be solved arises from the field of medical imaging, where a pulmonary CT-based standardized reporting system could be addressed as a solution. The core of it focuses on certain impediments such as the overworking of doctors, aiming essentially to solve a classification problem using deep learning techniques, namely, if a patient suffers from COVID-19, viral pneumonia, or is healthy from a pulmonary point of view. The methodology’s approach was a meticulous one, denoting an empirical character in which the initial stage, given using data processing, performs an extraction of the lung cavity from the CT scans, which is a less explored approach, followed by data augmentation. The next step is comprehended by developing a CNN in two scenarios, one in which there is a binary classification (COVID and non-COVID patients), and the other one is represented by a three-class classification. Moreover, viral pneumonia is addressed. To obtain an efficient version, architectural changes were gradually made, involving four databases during this process. Furthermore, given the availability of pre-trained models, the transfer learning technique was employed by incorporating the linear classifier from our own convolutional network into an existing model, with the result being much more promising. The experimentation encompassed several models including MobileNetV1, ResNet50, DenseNet201, VGG16, and VGG19. Through a more in-depth analysis, using the CAM technique, MobilneNetV1 differentiated itself via the detection accuracy of possible pulmonary anomalies. Interestingly, this model stood out as not being among the most used in the literature. As a result, the following values of evaluation metrics were reached: loss (0.0751), accuracy (0.9744), precision (0.9758), recall (0.9742), AUC (0.9902), and F1 score (0.9750), from 1161 samples allocated for each of the three individual classes.

13 April 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
APAlexandru-Florian Popov
Alexandru-Florian Popov
DKDominic Mircea Kristaly
Dominic Mircea Kristaly
DBDragoș-Vasile Bratu
Dragoș-Vasile Bratu
MZMaria-Alexandra Zolya
Maria-Alexandra Zolya
SMSorin-Aurel Moraru
Sorin-Aurel Moraru
Railway systems are sometimes faced with the necessity of decommissioning railway stations due to issues in the electricity supply system, control system failures, or a decrease in train traffic. In order for fully or partially decommissioned stations to maintain functionality and turnout availability, the researchers propose the use of a computer system utilizing GSM technology. Using AES-encrypted SMS messages, GSM signaling can be applied to a wide range of electrical equipment at decommissioned stations, enabling monitoring and control of these installations remotely, as well as allowing for integration into an existing SCADA system. This study attempts to estimate the reduction in total delays and operating cost that would arise when implementing this control system in a low-resource setting. An impact and cost analysis was performed on a rail section with partially decommissioned stations (Brașov–Codlea, Romania), to ascertain whether this control method would result in significant delay and cost reductions. The analyzed data show that the proposed control system can significantly reduce delays and costs on railway lines with decommissioned stations, thus allowing for a more efficient use of resources. By leveraging technology to monitor and control electrical installations remotely, the need for physical presence at the decommissioned station is eliminated. Overall, the research described represents a significant step towards the more efficient and safe use of railway infrastructure, and could potentially lead to the reactivation of previously decommissioned stations, providing benefits for both passengers and freight transport operators.

8 March 2025 in Sensors
Verified
Journal Article
Open access
PDF file
MZMaria-Alexandra Zolya
Maria-Alexandra Zolya
EPElena-Laura Popa
Elena-Laura Popa
CBCosmin Baltag
Cosmin Baltag
DBDragoș-Vasile Bratu
Dragoș-Vasile Bratu
Simona ComanSimona Coman
Simona Coman
SMSorin-Aurel Moraru
Sorin-Aurel Moraru
Cardiovascular diseases (CVDs) are the leading cause of death worldwide, claiming over 17 million lives annually. Early detection of conditions like heart murmurs, often indicative of heart valve abnormalities, is critical for improving patient outcomes. Traditional diagnostic methods, including physical auscultation and advanced imaging techniques, are constrained by their reliance on specialized clinical expertise, inherent procedural invasiveness, substantial financial costs, and limited accessibility, particularly in resource-limited healthcare environments. This study presents a novel convolutional recurrent neural network (CRNN) model designed for the non-invasive classification of heart murmurs. The model processes heart sound recordings using advanced pre-processing techniques such as z-score normalization, band-pass filtering, and data augmentation (Gaussian noise, time shift, and pitch shift) to enhance robustness. By combining convolutional and recurrent layers, the CRNN captures spatial and temporal features in audio data, achieving an accuracy of 90.5%, precision of 89%, and recall of 87%. These results underscore the potential of machine-learning technologies to revolutionize cardiac diagnostics by offering scalable, accessible solutions for the early detection of cardiovascular conditions. This approach paves the way for broader applications of AI in healthcare, particularly in underserved regions where traditional resources are scarce.