An electrochemical sensory platform is presented for determination of sumatriptan (SUM) in aqueous solutions and human blood serum. A pencil graphite electrode (PGE) was electrochemically delaminated by cyclic voltammetry technique, and then further modified using nanoparticles of a zinc-based metal–organic framework (Zn(II)-MOF). The fabricated Zn(II)-MOF/EDPGE electrode was utilized for sensitive electrochemical detection of SUM via an electro-oxidation reaction. The Zn(II)-MOF was hydrothermally synthesized and characterized by various techniques. The electrochemical delamination of PGE results in a porous substrate, facilitating the effective immobilization of the modifier. The designed sensor benefits from both enhanced surface area and an accelerated electron transfer rate, as evidenced by the chronocoulogram and Nyquist plots. Under optimized conditions, the developed sensor exhibited a linear response for 0.99–9.52 µM SUM solutions. A short response time of 5 s was observed for the fabricated sensor and the detection limit was found to be 0.29 μM. Selectivity of Zn(II)-MOF/EDPGE towards SUM was evaluated by examining the interference effect of codeine, epinephrine, acetaminophen, ascorbic acid, and uric acid, which are commonly found in biological samples. The developed sensor shows excellent performance with recovery values falling within the range of 96.6 to 111% for the analysis of SUM in human blood serum samples.
The g-C3N4/CS biosensor was designed, fabricated, and tested using compounds such as glucose, urine, lactose, and flutamide at a molarity of 10 µM, which could demonstrate a high sensitivity of 200 μm-1 for flutamide. Powerful effective medium theory and FDTD simulation were used to predict the most favorable mode and plasmonic properties of a graphite carbon nitride and chitosan nanocomposite. The research also explores the characteristics of surface plasmon resonance exhibited by the nanocomposite as the chitosan content is adjusted. Subsequent simulations are conducted on nanocomposites incorporating a thin layer and a modified gold structure. The intricate simulations ultimately reveal the optimal combination, tested under three different pH conditions (6.2, 7.2, and 8). In acidic conditions, the kinetic profile yielded a KD= 3.45 × 10−7, surpassing the KD value of a thin film. The Au significantly outperformed the alternative material. The biosensor demonstrated linear behavior across a wide concentration range from 1 to 150 µM, achieving a detection limit of 120 nM with its high sensitivity.