qin sun

Mrs. qin sun


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 October 2024 in Energy
Verified
Journal Article
Closed access
YCYunxiang Cai
Yunxiang Cai
QSqin sun
qin sun
XGXiaobin Gu
Xiaobin Gu
YLYuping Li
Yuping Li
WLWeimin Luo
Weimin Luo
KDKaijun Dong
Kaijun Dong

26 June 2024 in Energies
Verified
Journal Article
Open access
PDF file
LSLe Sun
Le Sun
JGJiafeng Geng
Jiafeng Geng
KDKaijun Dong
Kaijun Dong
QSqin sun
qin sun
With the rapid development of artificial intelligence, cloud computing and other technologies, data centers have become vital facilities. In the construction and operation of data centers, how to effectively solve the problem of cooling and energy saving is the key problem. In this review article, a critical review of recent research regarding the application of nanofluids in data center cooling are put forward. Many different aspects of nanofluids such as the classification of nanoparticles, base fluid components, and types and structures of heat exchangers were discussed. Furthermore, some advanced and up-to-date apparatus and theoretical models of utilizing nanofluids as coolants in data centers are reviewed and described in detail. Lastly, but not least, potential research directions in the future and the challenges faced by the researchers and industry in this field are proposed and discussed. In conclusion, nanofluids used as novel heat exchange medium, which has been widely proven in other areas, can also conspicuously improve data center cooling technology in the future.

8 March 2024 in Energies
Verified
Journal Article
Open access
PDF file
LSLe Sun
Le Sun
JGJiafeng Geng
Jiafeng Geng
KDKaijun Dong
Kaijun Dong
QSqin sun
qin sun
Thermal conductivity and viscosity are important properties for nanofluids as they significantly affect the flow and heat transfer process. To date, the rheological properties of water-based nanofluids have been well studied, while the results are scarce for non-aqueous nanofluids. In this study, the thermal conductivity and rheological properties of two different kinds of oxide nanofluids (CuO and Al2O3) in a typical commercial data center focusing on liquid coolants were systematically investigated at different mass fractions and temperatures. The results showed that the addition of nanoparticles can significantly improve the heat conduction capacity of mineral oil coolants. There is an average increase in thermal conductivity of up to 20–25%. The shear rate–shear stress and shear rate–viscosity curves all showed that mineral oil coolant-based oxide nanofluids behaved as Newtonian fluids and that nanoparticles did not cause the increment in viscosity. The effect of temperature on rheological properties was also studied, and the result showed that high temperatures resulted in low viscosity and shear stress. Finally, the effect of particle type was investigated, and it was found that no matter what kind of nanoparticles were added, their effects on the rheological behaviors were the same.

2 February 2022 in Journal of Building Engineering
Verified
Journal Article
Closed access
JHJin Hou
Jin Hou
XLXin Li
Xin Li
HWHang Wan
Hang Wan
QSqin sun
qin sun
KDKaijun Dong
Kaijun Dong
GHGongsheng Huang
Gongsheng Huang

20 June 2023 in Energies
Verified
Journal Article
Open access
PDF file
BZBobo Zhang
Bobo Zhang
QSqin sun
qin sun
LSLin Su
Lin Su
KDKaijun Dong
Kaijun Dong
WLWeimin Luo
Weimin Luo
Wei  WuWei Wu
Wei Wu
Radiation cooling, as a new terminal mode that has been gradually emerging in recent years, has attracted more and more attention. However, the problem of condensation has become a vital bottleneck restricting the broad application of radiation-cooling technology. This paper used the numerical simulation method of Ansys Fluent to study the effect of different water supply parameters on the concrete radiant roof’s heat transfer performance, temperature uniformity analysis, and anti-condensation temperature control strategy. The accuracy of the simulation model was verified by comparing the numerical simulation values and measured values of temperature monitoring points. In thermal performance research, the inlet temperature significantly impacted the cooling capacity and radiant surface temperature compared with the inlet flow velocity. In the uniformity study, the distance between the serpentine pipes area and the concrete edge was easily neglected, which was also an important factor affecting the distribution of temperature uniformity. Regarding anti-condensation and performance improvement research, first supplying water at low temperatures and then dynamically adjusting high-temperature water could effectively avoid condensation and improve the radiant roof’s heat transfer performance. The research results could provide technical references for the practical application of radiation roof anti-condensation temperature control technology.

16 April 2019 in Journal of Heat Transfer
Verified
Journal Article
Closed access
PDF file
QSqin sun
qin sun
YDYanhua Diao
Yanhua Diao
YZYaohua Zhao
Yaohua Zhao
STSheng Tang
Sheng Tang
JZJi Zhang
Ji Zhang
ZWZeyu Wang
Zeyu Wang