Purpose. To compare visual field results obtained using Melbourne Rapid Fields (MRF) iPad-based perimeter software and Humphrey Field Analyzer (HFA) 24-2 Swedish Interactive Threshold Algorithm (SITA) standard program in glaucoma patients. Design. A cross-sectional observational study. Methods. In this single-centre study involving patients diagnosed with glaucoma, the perimetric outcomes of MRF were compared against those returned from the HFA 24-2 SITA standard. Outcomes included mean deviation (MD), pattern standard deviation (PSD), visual field index (VFI)/visual capacity (VC), foveal threshold, test time, number of points depressed at on PSD probability plot, and glaucoma hemifield test/color coded indicator. Results. The study included 28 eyes of 28 glaucoma patients. Mean (standard deviation) test times were 342.07 (56.70) seconds for MRF and 375.11 (88.95) for HFA 24-2 SITA standard . Mean MD was significantly lower for MRF (Δ = 3.09, ), and mean PSD was significantly higher for MRF (Δ = 1.40, ) compared with HFA. The mean foveal threshold for the MRF was significantly lower than the mean HFA foveal threshold ((Δ = 9.25, ). The number of points depressed at on the PSD probability plot was significantly less for MRF . Other perimetric outcomes showed no significant differences between both. Bland–Altman plots showed that considerable variability existed between the programs. Conclusion. MRF is a good cost-effective, time-saving, user-friendly tool for monitoring visual fields in settings where access to traditional perimetry is limited. The lack of Internet strength in rural areas and questionable detection of early cases may be two points in MRF fields requiring an upgrade.
Purpose: To analyse topographic and tomographic changes in fellow eyes of unilateral keratoconus patients by comparing them with normal eyes. Methods: This five-year retrospective observational comparative case study included 15 advanced keratoconus eyes of unilateral keratoconus (KCN group), 15 normal fellow eyes of unilateral keratoconus (Fellow eye group) and 34 eyes of normal refractive surgery candidates (Normal group). Topographic and tomographic data, data from enhanced elevation maps, and keratoconus indices were measured in all study eyes using Pentacam. Receiver operating characteristic (ROC) curves were used to evaluate the area under the curve (AUC), sensitivity and specificity of each parameter and identify cut-off points in discriminating between the fellow and normal eyes. Results: Corneal thickness at the apex (CTA, P = 0.001) and at the thinnest point (CTT, P < 0.001), corneal volume (CV, P = 0.007), Belin/Ambrosio Enhanced Ectasia Display (BAD) - thinnest point (Dt, P = 0.002) and thinnest point displacement (Da, P = 0.002) were significantly lower in the fellow group compared to eyes of normal subjects. On ROC curve analysis, the most efficient distinguishing indices between the fellow group and normal controls were BAD - overall D value (AUC = 0.859), Dt (AUC =0.827), Da (AUC = 0.789) followed by pachymetric progression index maximum (AUC = 0.741). Conclusion: BAD-D value and pachymetric progression index could be useful in detecting the earliest form of subclinical keratoconus. However, every single parameter alone is not enough to detect early changes; a combination of different data is required to distinguish subclinical keratoconus.
Retropupillary iris-claw intraocular lenses (ICIOLs) have been increasingly chosen by surgeons nowadays as a primary or secondary procedure of IOL implantation in eyes with insufficient capsular or zonular support. They have gained popularity due to their simple fast technique, favourable functional outcomes, and safety. The transition in the ICIOL fixation from prepupillary to a more biologically appropriate retropupillary position and change in the optic design from biconvex to convex–concave have provided better visual outcomes and improved safety. A peer-reviewed literature search was conducted in Medline (PubMed), Embase, and Cochrane Library using the keywords “retropupillary iris claw” and “iris claw”. The search yielded 310 articles that were screened. Forty-three articles on retropupillary ICIOLs were finally found to be relevant and reviewed in full-text versions. The functional outcomes following retropupillary implantation of ICIOLs have been acceptable in eyes with no ocular co-morbidities otherwise. However, the indications for surgery may affect the outcomes. The major postoperative complications directly associated with ICIOLs include pupil ovalization and redislocation. Nevertheless, the rate of disenclavation depends on the experience and skill of the surgeon. This review is based on a literature review, and it focuses on the preoperative evaluation, surgical technique, postoperative outcomes, and associated complications. Prospective randomized trials with a larger sample size and longer follow-up are needed for comparison with other techniques of IOL fixation and confirmation of long-term safety profile.
Purpose: To evaluate the outcomes of implantation of an iris-claw intraocular lens (IC-IOL) in retropupillary position in aphakic patients. Methods: We conducted a prospective interventional study, including 36 aphakic eyes with inadequate capsular support. The postoperative examination included best-corrected visual acuity (BCVA), intraocular pressure (IOP) measurement, central corneal thickness (CCT), and anterior segment examination with emphasis on the anterior chamber reaction and shape of pupil. Follow-up was done for 3 months. Results: Thirty-six eyes of 34 patients, including 22 right eyes and 14 left eyes were included. Indications for surgery were complicated cataract surgery in 38.9% (n = 14), aphakia in 27.8% (n = 10), pseudophakic bullous keratopathy in 16.7% (n = 6), dislocated posterior chamber IOL (PCIOL) in 11.1% (n = 4), IC drop in 2.8% (n = 1), and subluxated PCIOL in 2.8% (n = 1). Postoperatively, the visual acuity improved by at least two lines in 32 (88.9%) and worsened in four (11.1%) eyes at the end of three months. Mean postoperative IOP at the end of the third month was 12.42 mmHg (standard deviation [SD] 2.57; range 11.55–13.29 mmHg). The mean postoperative CCT at the end of the third month was 542.42 microns (SD 13.77; range 537.76–547.07 microns). Sixteen eyes (44.4%) had horizontally oval pupil, eleven eyes (30.6%) had round pupil, and nine eyes (25%) had irregular pupil. Twenty-three eyes (63.9%) presented with significant anterior chamber reaction and seven eyes (19.4%) had corneal stromal edema on postoperative day 1. Conclusion: Our study demonstrated that retropupillary IC-IOL implantation in eyes without adequate capsular support is an effective and safe procedure with a good visual outcome and fewer complications.
10 December 2021 in Taiwan Journal of Ophthalmology
Toric intraocular lenses (IOLs) are universally recommended in cataract cases with preoperative corneal astigmatism ≥1.5 D. An optimal surgical outcome depends on careful patient selection, complete preoperative evaluation, accurate IOL power calculation, precise marking of the axis, meticulous intraoperative approach, and methodical postoperative care. Understanding the importance of posterior corneal astigmatism, surgically induced astigmatism, and effective lens position in IOL power calculation and newer techniques to measure them directly have resulted in better postoperative refractive outcomes. We present a brief overview of toric IOLs along with the preoperative evaluation, IOL power calculation, different marking methods, intraoperative approach, and postoperative outcomes. Functional and anatomical outcomes, including uncorrected visual acuity, residual refractive astigmatism, and postoperative IOL misalignment, which have been reported for both toric IOLs and multifocal toric IOLs, are reviewed.
Précis: Swedish Interactive Threshold Algorithm (SITA) Faster (SFR) saves considerable test time but needs further amendments for considering it to be an accurate test that can replace SITA Fast (SF) or SITA Standard (SS). Purpose: To compare visual field results obtained using SFR, SF, and SS programs in patients with manifest and suspect glaucoma. Materials and Methods: In this cross-sectional observational study involving manifest patients with glaucoma and glaucoma suspects, perimetric outcomes of SFR, SF, and SS were compared. Outcomes included test time, mean deviation, pattern standard deviation (PSD), Visual Field Index (VFI), foveal threshold, number of points depressed at P<5%, P<2%, P<1%, and P<0.5% on PSD probability plot, individual threshold test points, glaucoma hemifield test, and grade of field defect. Results: Seventy eyes of 70 patients were included in this study. SFR test times averaged 36.1% shorter than SF and 60.7% shorter than SS (P<0.001). Mean deviation values were lower with SFR compared with both SF and SS (Δ=1.5, P<0.001). Mean PSD and VFI showed no significant differences between the algorithms. The mean foveal threshold was higher for SFR compared with SF (Δ=1.6, P<0.001) and SS (Δ=2.1, P<0.001). The number of points depressed at P<0.5% was lesser in SFR than in both SF and SS (P=0.002). Bland-Altman plots showed that considerable variability existed between the algorithms. Conclusion: SFR provides benefits in test time and shows similar VFI compared with SF and SS. However, the detection of early cases with SFR is questionable and few modifications are needed in the future to improve its accuracy. SF and SS gave almost similar results. The algorithms cannot be used interchangeably for the same patient on different test sessions.