Kalamalla Ayappa SaranBabu

Prof. Dr. Kalamalla Ayappa SaranBabu


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2018 in Journal of International Society of Preventive and Community Dentistry
Verified
Journal Article
Open access
PDF file
SISrikanth Ikkurthi
Srikanth Ikkurthi
VBV Ramesh Babu
V Ramesh Babu
DPDinesh Kumar Perisetty
Dinesh Kumar Perisetty
KSKalamalla Ayappa SaranBabu
Kalamalla Ayappa SaranBabu
MRMahammad Rasool
Mahammad Rasool
SSShanawaz Shaik
Shanawaz Shaik
AimsandObjectives: The aim of this work was to assess the advantages and disadvantages of magnetic resonance imaging?(MRI) versus computed tomography?(CT) in the initial evaluation of maxillofacial space infections by comparing various parameters of the imaging studies and comparing them on a three-point scale. Materials and Methods: We prospectively evaluated 15?patients with head and neck space infections. All patients underwent CT and MRI using similar slice thickness. We reviewed all imaging studies with special attention to location, extension, source of infection, extent of bone involvement, odontogenic or nonodontogenic, and presence of gas/calcium in the lesions. All the parameters were graded based on a three-point scale and were compared statistically by paired t-test. Results: According to the results we arrived at, MRI was superior to CT in regard to lesion conspicuity, extension, number of anatomic spaces involved, and source on infection. Although not significant, MRI detected a greater number of abscess collections. However, in the aspects of detection of intralesional gas and calcium and motion artifacts, CT was superior to MRI. However, these advantages of CT over MRI are not significantly better than those of MRI. Conclusion: MRI was considered superior to CT in the initial evaluation of head and neck space infections. Our study thus concludes that MRI may be used as the primary modality to evaluate patients with head and neck infections when clinically feasible.

1 January 2019 in Journal of International Society of Preventive and Community Dentistry
Verified
Journal Article
Open access
PDF file
KSKalamalla Ayappa SaranBabu
Kalamalla Ayappa SaranBabu
DPDinesh Kumar Perisetty
Dinesh Kumar Perisetty
GTGunaranjan Thota
Gunaranjan Thota
MRMahammad Rasool
Mahammad Rasool
MNMungara Niharika
Mungara Niharika
SSSannapureddy Swapna
Sannapureddy Swapna
Objectives: To test the hypothesis that radius of curvature at gingival embrasure in connector area significantly affects the fracture resistance of full-contour monolithic zirconia three-unit posterior Fixed partial denture (FPD) on various amounts of load application. Materials and Methods: In this study, two types of three-dimensional finite element models of a three-unit posterior full-contour monolithic zirconia FPD with two gingival embrasure radii (rGE I, 0.45mm and rGE II, 0.25mm) were constructed. The components modeled through finite element modeling were subjected to 400, 600, and 800N vertical loads at the central fossa of the pontic, and further analysis was carried out. Results: All the results were displayed by post-processor finite element analysis software (ANSYS). The study revealed that with increase in the amount of load application as well as decrease in the gingival embrasure radii, stress concentration values were increasing gradually for both the full-contour monolithic zirconia FPD. Conclusion: The fracture resistance of the zirconia posterior FPD was significantly affected by the gingival embrasure radii and the mode of load application. When there is a clinical situation of heavier occlusal forces, the fracture resistance can be increased by designing greater gingival embrasure radii in the connector region.

22 October 2019 in Global Journal of Medical Research
Verified
Journal Article
Open access
PDF file
KSKalamalla Ayappa SaranBabu
Kalamalla Ayappa SaranBabu
MRMahammad Rasool
Mahammad Rasool
DPDinesh Kumar Perisetty
Dinesh Kumar Perisetty
CSCh. Sumalatha
Ch. Sumalatha
ESE. Srikanth
E. Srikanth
SSSateesh Babu S
Sateesh Babu S
Retention, stability & support are three important factors which determine the basic objectives, success and comfort of any removable prosthesis.In acquired surgical maxillary defects; the degree of impairment, size and location of the defect influences the outcome of the overall prosthetic overhaul.Prosthetic therapy with obturator closes the defect by re-establishing the oro-nasal separation, thereby, improving deglutition, speech and hypernasality. After maxillectomy, 3-6 months after surgery,patients with class 4 maxillary defects complains of frequent loosening of temporary prosthesis due to more amount of tissue changes, dimensional stabilization of surgical site, more loss of mucogingival support and rapid healing changes. As a result, there is an every chance of endangerment with the use of temporary prosthesis and allow the patients in seeking the definitive prosthesis over interim prosthesis. In this regard, designing of cast partial metal frame work with linear configuration for class 4 maxillary defects enhances the quality and comfort of the definitive prosthesis over conventional acrylic prosthesis. This article mainly describes the fundamental designing technique in improving the retention, stability and support of the definitive prosthesis with cast retainers.

15 October 2019 in IP Annals of Prosthodontics and Restorative Dentistry
Verified
Journal Article
Open access
PDF file
PHPonnapalli Haripriya
Ponnapalli Haripriya
KSKalamalla Ayappa SaranBabu
Kalamalla Ayappa SaranBabu
SPSrinivas Rao Pottem
Srinivas Rao Pottem
HVHanuman Chalapathi Kumar Voleti
Hanuman Chalapathi Kumar Voleti
PTPavan Kumar Tannamala
Pavan Kumar Tannamala
Management of Xerostomia in edentulous patient associated with multiple local conditions a case report-APRD-Print ISSN No:-2581-4796 Online ISSN No:-2581-480XArticle DOI No:-10.18231/j.aprd.2019.018,IP Annals of Prosthodontics and Restorative Dentistry-IP Innovative Publication Pvt Limited, Medical Journals Publicati

21 October 2019 in International Journal of Oral Health Dentistry
Verified
Journal Article
Open access
PDF file
KSKalamalla Ayappa SaranBabu
Kalamalla Ayappa SaranBabu
PHPonnapalli Haripriya
Ponnapalli Haripriya
SPSrinivas Rao Pottem
Srinivas Rao Pottem
HVHanuman Chalapathi Kumar Voleti
Hanuman Chalapathi Kumar Voleti
PTPavan Kumar Tannamala
Pavan Kumar Tannamala
FPD with difference in connectors: A case report-IJOHD-Print ISSN No:-2395-4914 Online ISSN No:-2395-499XArticle DOI No:-10.18231/j.ijohd.2019.033,International Journal of Oral Health Dentistry-IP Innovative Publication Pvt Limited, Medical Journals Publication, Open Access Journals, Print Journals,Indian Journals,

2 January 2026 in International Journal of Oral Health Dentistry
Verified
Journal Article
Open access
KSKalamalla Ayappa SaranBabu
Kalamalla Ayappa SaranBabu
PTPavan Kumar Tannamala
Pavan Kumar Tannamala
PYPoojitha Y
Poojitha Y
DTDevarapalli Sai Tejaswi
Devarapalli Sai Tejaswi
MPMano Kumar Paturu
Mano Kumar Paturu
For elderly and medically impaired individuals, complete dentures continue to be essential to oral rehabilitation. With an emphasis on material science, digital design, patient-centered care, artificial intelligence, and sustainable fabrication, the integration of digital workflows, regenerative materials, and smart technologies is propelling prosthodontics into a new era, surpassing the limitations of traditional static prostheses in current practices and future directions in complete denture therapy. High-performance polymers, CAD/CAM systems, digital impressions, smart sensors, and bioactive liners are examples of recent advances. Bioprinted regenerative bases and AI-driven design platforms have the potential to improve patient happiness, customisation, durability, and hygiene. Despite these developments, issues with clinical training, accessibility, and regulatory validation still exist. In general, complete denture therapy is moving toward a paradigm shift of intelligent, sustainable, and customized prosthetics, necessitating ongoing multidisciplinary research and equitable integration into routine care.