Anna Fischbach

Dr. Anna Fischbach

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 October 2019 in Science Translational Medicine
Verified
Journal Article
Closed access
PDF file
LZLuca Zazzeron
Luca Zazzeron
AFAnna Fischbach
Anna Fischbach
WFWalfre Franco
Walfre Franco
WFWilliam A. Farinelli
William A. Farinelli
FIFumito Ichinose
Fumito Ichinose
WZWarren M. Zapol
Warren M. Zapol
Extracorporeal blood phototherapy increases carbon monoxide elimination in rats and improves survival in animals with associated lung injury.

5 August 2021 in Lasers in Surgery and Medicine
Verified
Journal Article
Closed access
PDF file
AFAnna Fischbach
Anna Fischbach
SWSteffen B. Wiegand
Steffen B. Wiegand
LZLuca Zazzeron
Luca Zazzeron
LTLisa Traeger
Lisa Traeger
RFRaffaele di Fenza
Raffaele di Fenza
WZWarren M. Zapol
Warren M. Zapol

17 March 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
MTMuhammet Türkmen
Muhammet Türkmen
Tobias LauwigiTobias Lauwigi
Tobias Lauwigi
TFTamara Fechter
Tamara Fechter
FGFabienne Gries
Fabienne Gries
AFAnna Fischbach
Anna Fischbach
PWPatrick Winnersbach
Patrick Winnersbach
Clot formation inside a membrane oxygenator (MO) due to blood-to-foreign surface interaction represents a frequent complication during extracorporeal membrane oxygenation. Since current standard monitoring methods of coagulation status inside the MO fail to detect clot formation at an early stage, reliable sensors for early clot detection are in demand to reduce associated complications and adverse events. Bioimpedance analysis offers a monitoring concept by integrating sensor fibers into the MO. Herein, the feasibility of clot detection via bioimpedance analysis is evaluated. A custom-made test chamber with integrated titanium fibers acting as sensors was perfused with heparinized human whole blood in an in vitro test circuit until clot formation occurred. The clot detection capability of bioimpedance analysis was directly compared to the pressure difference across the test chamber (ΔP-TC), analogous to the measurement across MOs (ΔP-MO), the clinical gold standard for clot detection. We found that bioimpedance measurement increased significantly 8 min prior to a significant increase in ΔP-TC, indicating fulminant clot formation. Experiments without clot formation resulted in a lack of increase in bioimpedance or ΔP-TC. This study shows that clot detection via bioimpedance analysis under flow conditions in a blood-perfused test chamber is generally feasible, thus paving the way for further investigation.

24 August 2024 in Journal of Cardiothoracic Surgery
Verified
Journal Article
Open access
PDF file
AFAnna Fischbach
Anna Fischbach
JSJulia Alexandra Simons
Julia Alexandra Simons
SWSteffen B. Wiegand
Steffen B. Wiegand
LALieselotte Ammon
Lieselotte Ammon
RKRüdger Kopp
Rüdger Kopp
GSGereon Schälte
Gereon Schälte
Background: Surgical aortic valve replacement (SAVR) is an established therapy for severe calcific aortic stenosis. Enhanced recovery after cardiac surgery (ERACS) protocols have been shown to improve outcomes for elective cardiac procedures. The COVID-19 pandemic prompted early extubation post-elective surgeries to preserve critical care resources. Aim of this study: To investigate the effects of extubating patients within 6 h post-elective SAVR on hospital and ICU length of stay, mortality rates, ICU readmissions, and postoperative pneumonia. Study Design and methods: The retrospective analysis at the University Hospital Aachen, Germany, includes data from 2017 to 2022 and compares a total of 73 elective SAVR patients. Among these, 23 patients were extubated within 6 h (EXT group), while 50 patients remained intubated for over 6 h (INT group). Results: The INT group experienced longer postoperative ventilation, needed more vasopressor support, had a higher incidence of postoperative pneumonia, and longer ICU length of stay. No significant differences were noted in overall hospital length of stay, mortality, or ICU readmission rates between the groups. Conclusion: This study demonstrates that early extubation in high-risk, multimorbid surgical aortic valve replacement patients is safe, and is associated with a reduction of pneumonia rates, and with shorter ICU and hospital length of stays, reinforcing the benefits of ERACS protocols, especially critical during the COVID-19 pandemic to optimize intensive care use.

8 March 2023 in Lasers in Surgery and Medicine
Verified
Journal Article
Open access
AGAnastasia Goulopoulos
Anastasia Goulopoulos
EEEdidiong Etim
Edidiong Etim
SKSandeep Korupolu
Sandeep Korupolu
WFWilliam Farinelli
William Farinelli
HSHeidy Sierra
Heidy Sierra
Walfre FrancoWalfre Franco
Walfre Franco
Background: Extracorporeal membrane oxygenators (ECMO) are currently utilized to mechanically ventilate blood when lung or lung and heart function are impaired, like in cases of acute respiratory distress syndrome (ARDS). ARDS can be caused by severe cases of carbon monoxide (CO) inhalation, which is the leading cause of poison‐related deaths in the United States. ECMOs can be further optimized for severe CO inhalation using visible light to photo‐dissociate CO from hemoglobin (Hb). In previous studies, we combined phototherapy with an ECMO to design a photo‐ECMO device, which significantly increased CO elimination and improved survival in CO‐poisoned animal models using light at 460, 523, and 620 nm wavelengths. Light at 620 nm was the most effective in removing CO.Objective: The aim of this study is to analyze the light propagation at 460, 523, and 620 nm wavelengths and the 3D blood flow and heating distribution within the photo‐ECMO device that increased CO elimination in CO‐poisoned animal models.Methods: Light propagation, blood flow dynamics, and heat diffusion were modeled using the Monte Carlo method and the laminar Navier‐Stokes and heat diffusion equations, respectively.Results: Light at 620 nm propagated through the device blood compartment (4 mm), while light at 460 and 523 nm only penetrated 48% to 50% (~2 mm). The blood flow velocity in the blood compartment varied with regions of high (5 mm/s) and low (1 mm/s) velocity, including stagnant flow. The blood temperatures at the device outlet for 460, 523, and 620 nm wavelengths were approximately 26.7°C, 27.4°C, and 20°C, respectively. However, the maximum temperatures within the blood treatment compartment rose to approximately 71°C, 77°C, and 21°C, respectively.Conclusions: As the extent of light propagation correlates with efficiency in photodissociation, the light at 620 nm is the optimal wavelength for removing CO from Hb while maintaining blood temperatures below thermal damage. Measuring the inlet and outlet blood temperatures is not enough to avoid unintentional thermal damage by light irradiation. Computational models can help eliminate risks of excessive heating and improve device development by analyzing design modifications that improve blood flow, like suppressing stagnant flow, further increasing the rate of CO elimination.

17 October 2021 in Lasers in Surgery and Medicine
Verified
Journal Article
Closed access
PDF file
AFAnna Fischbach
Anna Fischbach
LTLisa Traeger
Lisa Traeger
WFWilliam A. Farinelli
William A. Farinelli
MEMariko Ezaka
Mariko Ezaka
HWHatus V. Wanderley
Hatus V. Wanderley
WZWarren M. Zapol
Warren M. Zapol