This work presents an extensive study on methodologies to calibrate electric energy consumption in buildings. A comparison between several calibration methodologies shows different approaches addressing the same issue, suggesting a lack of a unique methodology that is reproducible for every building. Additionally, no methodology fits the Brazilian public context, such as the predominance of Unitary Air Conditioning Systems (UACS) and buildings which have operated for more than 30 years. A new calibration methodology for performance simulation is proposed to deal with such features. The methodology is separated into two evidence-based steps according to the size of the Heating, Ventilation and Air Conditioning (HVAC) systems used to control buildings’ indoor environments: the first step is dedicated to calibrating medium- and large-sized HVAC systems, and the second step is dedicated to calibrating small-sized HVAC systems. University Hospital of University of São Paulo (UH-USP) is used as a test bed to implement the proposed methodology. Accuracy indicators show the efficiency of the methodology in terms of calibrating a simulation of the whole UH-USP building and Chilled Water Plant on a monthly basis in terms of accuracy and the time needed to perform the calibration. However, regarding simulation of UACS, the application of the methodology was inconclusive. This study leaves open the question of the trade-off between increasing model outcome accuracy and the strictness of accuracy indicators applied to UACS and poorly automated large-sized air conditioners.
The most-used refrigeration system is the vapor-compression system. In this cycle, the compressor is the most complex and expensive component, especially the reciprocating semihermetic type, which is often used in food product conservation. This component is very sensitive to variations in its operating conditions. If these conditions reach unacceptable levels, failures are practically inevitable. Therefore, maintenance actions should be taken in order to maintain good performance of such compressors and to avoid undesirable stops of the system. To achieve such a goal, one has to evaluate the reliability of the system and/or the components. In this case, reliability means the probability that some equipment cannot perform their requested functions for an established time period, under defined operating conditions. One of the tools used to improve component reliability is the failure mode and effect analysis (FMEA). This paper proposes that the methodology of FMEA be used as a tool to evaluate the main failures found in semihermetic reciprocating compressors used in refrigeration systems. Based on the results, some suggestions for maintenance are addressed.