This paper analyzed and discussed the nonlinear PI/PD control for wind energy conversion system (WECS) pitch controller design. The nonlinear PI/PD controller consists of a classical PI/PD controller and a nonlinear gain table. In this paper, the detailed design procedures of the controller including not only the selection of control parameters but also the formulation of nonlinear gain table were given. In order to verify the effectiveness and correctness of the algorithm, a detailed 2 MW simulation test platform based on MATLAB/SIMULINK environment was established. Meanwhile, some valuable conclusions were also obtained. The presented contents of this article have the reference value and guiding significance for practical engineering application.
This paper provides a systematic analysis of the large scale PMSG (permanent magnet synchronous generator)-based WECS (wind energy conversion system) torsional vibration problem under MPPT (maximum power point tracking) control and constant power control. This is from the perspective of SSO (sub-synchronous oscillation), SSH (sub-synchronous harmonics) and forced torsional vibration. The cause of SSO is the negative total system damping, weakened by the constant power control. The system is susceptible to inducing SSH in the grid current and voltage in the under-damped condition. To effectively suppress the torsional vibration of PMSG-based WECS, a stiffness compensation control strategy based on adaptive damping is proposed. The results show that SSO, SSH and the forced torsional vibration can be suppressed at the source using the proposed suppression strategy.
Because the PMSG (permanent magnet synchronous generator)‐based WECS (wind energy conversion system) has some uncertainties, the conventional control strategy with poor robustness is sometimes difficult to meet the performance requirements of control. In order to ensure efficient and stability of the system, this paper proposed a novel PI (proportional‐integral)‐type SMC (sliding mode control) strategy for PMSG‐based WECS uncertainties and presented the detailed analysis and design process. Compared with the conventional control method, the PI‐type SMC proposed in this paper not only can make the closed‐loop system globally stable, but also has a better robustness and slightly reduced the current ripple and distortion. Finally, the simulation results verify the correctness and effectiveness of this algorithm.
This paper proposes a robust control strategy for the uncertainties of permanent magnet synchronous generator-based wind energy conversion system, based on state feedback. Meanwhile, the detailed design and analysis process of this robust controller also have been presented. Compared with the conventional control, the new method with a better robustness can not only make the whole closed-loop system stable but also reduce the major harmonics and total harmonic distortion of currents and ripples of torque. And then, we set up a detailed 2 MW simulation test platform based on MATLAB/SIMULINK/SimPowerSysterms. The simulation results verify the effectiveness and correctness of the algorithm.
The oscillations on output power and distortion of the inverter currents will occur in the case of unbalanced grid voltage faults. Constant output power and good current quality cannot be achieved simultaneously. Aiming at these problems, a coordinate control strategy for suppressing power fluctuations and current harmonics is proposed by analyzing instantaneous power control and current balance control. The proposed control is achieved by adjusting the weight coefficient of current reference values to change the current harmonic contents based on proportional complex integral (PCI) controller and proportional multiple complex integral (PMCI) controller. The control strategy with a simple control structure neither needs to detect harmonic components of the inverter currents, nor needs to separate the positive and negative components of voltage and current, which is easy to be realized. The feasibility and effectiveness of the proposed control are verified by the comparison and analysis of simulation.