The aim of this paper is to demonstrate the impact of ambient air humidity on the efficiency of heat sink operation. It was observed that increased air humidity enabled higher power dissipation in a transistor used as a test device, without increasing its junction temperature. The presented simulation results are showing a correlation between air humidity and an estimated heat flux value. The paper also contains a mathematical analysis of humidity impact on the convective heat transfer coefficient. The natural convection phenomena are visualized in different infrared spectral ranges. A multispectral approach revealed that this convective air flow is best viewed in the MWIR spectral range.
The aim of this paper is to demonstrate the application of a reflective diffraction grating and a MWIR thermographic camera for gas identification and its concentration estimation. For this purpose a special setup was built using an infrared camera, a diffraction grating, a black body as infrared source and an air-tight tube that was filled with different mixtures of carbon monoxide, carbon dioxide and nitrogen. Both ends of the tube were closed using infrared transmission windows, allowing the radiation from the blackbody to pass through the tube and be measured with the camera. After spectral calibration of the setup, it was used for the detection, identification and concentration measurements of different gas mixtures.
15 November 2022 in Quantitative InfraRed Thermography Journal
Thermographic cameras are often used in areas, where resolutions below 100 µm per pixel are required, as for example in electronics. Such resolutions can be obtained using dedicated lenses. As an alternative, some manufacturers are offering extension rings to be added between the lens and the camera housing, to increase the final image spatial resolution. To test the latter solution and its impact on thermographic temperature measurements, a set of aluminium extension rings was manufactured and mounted in different combinations between an InSb cooled thermographic camera and its lens. Next, the camera, a blackbody IR source, a thick-film resistor on alumina substrate, a microscope reticle calibration glass, and two integrated test circuits were used to investigate the impact of the rings on the temperature measurement accuracy and the achieved spatial resolution. It was demonstrated, that extension rings are a very useful tool in thermography, as long as their impact on the measurement system is taken into account, considering numerical aperture reduction, rings heating by the operating camera, and the cold stop related vignetting. The impact will greatly depend on the specific design of the camera to be used and its lens configuration.