Alexander Kupferthaler

Dr. Alexander Kupferthaler

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2009 in Journal of Breath Research
Verified
Journal Article
Closed access
PDF file
JKJ King
J King
AKAlexander Kupferthaler
Alexander Kupferthaler
KUKarl Unterkofler
Karl Unterkofler
HKH Koc
H Koc
STS Teschl
S Teschl
AAAnton Amann
Anton Amann
A real-time recording setup combining exhaled breath volatile organic compound (VOC) measurements by proton transfer reaction-mass spectrometry (PTR-MS) with hemodynamic and respiratory data is presented. Continuous automatic sampling of exhaled breath is implemented on the basis of measured respiratory flow: a flow-controlled shutter mechanism guarantees that only end-tidal exhalation segments are drawn into the mass spectrometer for analysis. Exhaled breath concentration profiles of two prototypic compounds, isoprene and acetone, during several exercise regimes were acquired, reaffirming and complementing earlier experimental findings regarding the dynamic response of these compounds reported by Senthilmohan et al (2000 Redox Rep. 5 151–3) and Karl et al (2001 J. Appl. Physiol. 91 762–70). While isoprene tends to react very sensitively to changes in pulmonary ventilation and perfusion due to its lipophilic behavior and low Henry constant, hydrophilic acetone shows a rather stable behavior. Characteristic (median) values for breath isoprene concentration and molar flow, i.e., the amount of isoprene exhaled per minute are 100 ppb and 29 nmol min−1, respectively, with some intra-individual day-to-day variation. At the onset of exercise breath isoprene concentration increases drastically, usually by a factor of ~3–4 within about 1 min. Due to a simultaneous increase in ventilation, the associated rise in molar flow is even more pronounced, leading to a ratio between peak molar flow and molar flow at rest of ~11. Our setup holds great potential in capturing continuous dynamics of non-polar, low-soluble VOCs over a wide measurement range with simultaneous appraisal of decisive physiological factors affecting exhalation kinetics. In particular, data appear to favor the hypothesis that short-term effects visible in breath isoprene levels are mainly caused by changes in pulmonary gas exchange patterns rather than fluctuations in endogenous synthesis.

28 July 2010 in Physiological Measurement
Verified
Journal Article
Closed access
JKJ King
J King
PMPaweł Mochalski
Paweł Mochalski
AKAlexander Kupferthaler
Alexander Kupferthaler
KUKarl Unterkofler
Karl Unterkofler
HKH Koc
H Koc
AAA Amann
A Amann
In this phenomenological study we focus on dynamic measurements of volatile organic compounds (VOCs) in exhaled breath under exercise conditions. An experimental setup efficiently combining breath-by-breath analyses using proton transfer reaction mass spectrometry (PTR-MS) with data reflecting the behaviour of major hemodynamic and respiratory parameters is presented. Furthermore, a methodology for complementing continuous VOC profiles obtained by PTR-MS with simultaneous SPME/GC-MS measurements is outlined. These investigations aim at evaluating the impact of breathing patterns, cardiac output or blood pressure on the observed breath concentration and allow for the detection and identification of several VOCs revealing characteristic rest-to-work transitions in response to variations in ventilation or perfusion. Examples of such compounds include isoprene, methyl acetate, butane, DMS and 2-pentanone. In particular, both isoprene and methyl acetate exhibit a drastic rise in concentration shortly after the onset of exercise, usually by a factor of about 3-5 within approximately 1 min of pedalling. These specific VOCs might also be interpreted as potentially sensitive indicators for fluctuations of blood or respiratory flow and can therefore be viewed as candidate compounds for future assessments of hemodynamics, pulmonary function and gas exchange patterns via observed VOC behaviour.

1 December 2010 in Journal of Theoretical Biology
Verified
Journal Article
Closed access
JKJulian King
Julian King
HKHelin Koc
Helin Koc
KUKarl Unterkofler
Karl Unterkofler
PMPaweł Mochalski
Paweł Mochalski
AKAlexander Kupferthaler
Alexander Kupferthaler
AAAnton Amann
Anton Amann

28 February 2012 in Physiological Measurement
Verified
Journal Article
Closed access
JKJulian King
Julian King
AKAlexander Kupferthaler
Alexander Kupferthaler
BFBirgit Frauscher
Birgit Frauscher
HHHeinz Hackner
Heinz Hackner
KUKarl Unterkofler
Karl Unterkofler
BHBirgit Högl
Birgit Högl
This explorative study aims at characterizing the breath behavior of two prototypic volatile organic compounds, acetone and isoprene, during normal human sleep and to possibly relate changes in the respective concentration time courses to the underlying sleep architecture. For this purpose, six normal healthy volunteers (two females, four males, age 20-29 years) were monitored over two consecutive nights (the first one being an adaption night) by combining real-time proton-transfer-reaction mass spectrometry measurements from end-tidal exhalation segments with laboratory-based polysomnographic data. Breath acetone concentrations increased overnight in all measurements, with an average relative change by a factor of up to 4 (median 2.5). Nighttime concentration maxima were usually recorded 2-3 h before lights on. For breath isoprene, a nocturnal increase in baseline concentrations of about 74% was observed, with individual changes ranging from 36-110%. Isoprene profiles exhibited pronounced concentration peaks, which were highly specific for leg movements as scored by tibial electromyography. Furthermore, relative to a linear trend, baseline isoprene concentrations decreased during the transition from the NREM to the REM phase of a complete sleep cycle.

1 May 2022 in European Journal of Surgical Oncology
Verified
Journal Article
Closed access
Patrick KirchwegerPatrick Kirchweger
Patrick Kirchweger
AKAlexander Kupferthaler
Alexander Kupferthaler
JBJonathan Burghofer
Jonathan Burghofer
GWGerald Webersinke
Gerald Webersinke
EJEmina Jukic
Emina Jukic
HWHelwig Wundsam
Helwig Wundsam

10 November 2011 in Journal of Breath Research
Verified
Journal Article
Closed access
PMPaweł Mochalski
Paweł Mochalski
JKJulian King
Julian King
AKAlexander Kupferthaler
Alexander Kupferthaler
KUKarl Unterkofler
Karl Unterkofler
HHHartmann Hinterhuber
Hartmann Hinterhuber
AAAnton Amann
Anton Amann
The aim of this study was to determine the solubility (liquid-to-air ratios) of isoprene in water, human blood and plasma. To this end, an experimental setup combining multiple headspace extraction, solid phase microextraction and gas chromatography-mass spectrometry was applied. The water:air partition coefficients of isoprene were determined for the temperature range 4.5-37 °C and amounted to 1.171-0.277 (g mL(l)(-1)) (g mL(a)(-1))(-1). On the basis of these data, the enthalpy of volatilization was calculated as 29.46 ± 2.83 kJ mol(-1). The blood:air partition coefficients at 37 °C were determined for ten normal healthy volunteers spread around a median value of 0.95 ± 0.09 (g mL(l)(-1)) (g mL(a)(-1))(-1) and were approximately 16% lower than the plasma:air partition coefficients (1.11 ± 0.2). The applied methodology can be particularly attractive for solubility studies targeting species at very low concentrations in the solution, i.e. when headspace sample enrichment is necessary to provide sufficient measurement sensitivity and reliability. This can be especially helpful if environmental or physiological solute levels have to be considered.