Fernando. Carlos Pimentel

Mr. Fernando. Carlos Pimentel


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 December 2023 in Applied System Innovation
Verified
Journal Article
Open access
PDF file
RDRogério Duarte
Rogério Duarte
ÂNÂngela Lacerda Nobre
Ângela Lacerda Nobre
FPFernando. Carlos Pimentel
Fernando. Carlos Pimentel
Marc M. JacquinetMarc M. Jacquinet
Marc M. Jacquinet
Accreditation bodies call for curriculum development processes that are open to all stakeholders, reflecting viewpoints of students, industry, university faculty, and society. However, communication difficulties between faculty and non-faculty groups leave an immense collaboration potential unexplored. Using the classification of learning objectives, natural language processing, and data visualization, this paper presents a quantitative method that delivers program plan representations that are universal, self-explanatory, and empowering; promoting stronger links between program courses and curriculum development open to all stakeholders. A simple example shows how the method contributes to representative program planning experiences and a case study is used to confirm the method’s accuracy and utility.

8 November 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
RDRogério Duarte
Rogério Duarte
Maria da Glória GomesMaria da Glória Gomes
Maria da Glória Gomes
ARA. Moret Rodrigues
A. Moret Rodrigues
FPFernando. Carlos Pimentel
Fernando. Carlos Pimentel
Earth–air heat exchangers (EAHX) use the soil thermal capacity to dampen the amplitude of outdoor air temperature oscillations. This effect can be used in hot and dry climates for room cooling, and depending on the EAHX design, this cooling can be achieved with very few resources other than those used during EAHX construction. This is an obvious advantage compared to the significant energy consumption and operational costs of refrigeration machines traditionally used in room cooling. Despite the large number of papers on EAHXs available in the scientific literature, very few deal with large-diameter EAHXs (with pipe diameters larger than 0.30 m), and even fewer present monitoring data gathered from a built and functional large-diameter EAHX. The present paper uses monitoring data and provides a detailed quantitative analysis of the performance of a large-diameter EAHX built for standalone cooling of an existing office building. The field monitoring was carried out during a characteristic hot and dry summer period of the south of Portugal. Results show that outdoor air to EAHX exit air temperature gradients reach 9 K and cooling capacities exceed 27 kW. Moreover, the studied EAHX is capable of standalone cooling for outdoor air temperatures up to 33 °C and meets more than 50% of the room design cooling demand for outdoor air temperatures as high as 37 °C. This evidences that large-diameter EAHXs have the potential to achieve significant reductions in CO2 emissions and in energy consumption associated with building cooling in hot and dry climates.

16 July 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
RDRogério Duarte
Rogério Duarte
ARA. Moret Rodrigues
A. Moret Rodrigues
FPFernando. Carlos Pimentel
Fernando. Carlos Pimentel
Maria da Glória GomesMaria da Glória Gomes
Maria da Glória Gomes
Earth–air heat exchangers (EAHXs) use the soil’s thermal capacity to dampen the amplitude of outdoor air temperature oscillations. This effect can be used in hot and dry climates for room cooling with no or very little need for resources other than those used during the EAHX construction, an obvious advantage compared to the significant operational costs of refrigeration machines. Contrary to the streamlined process applied in conventional HVAC design (using refrigeration machines), EAHX design lacks straightforward and well-established rules; moreover, EAHXs struggle to achieve office room design cooling demands determined with conventional indoor thermal environment standards, hindering designers’ confidence and the wider adoption of EAHXs for standalone room cooling. This paper presents a graph-based method to assist in the design of a large-diameter EAHX. One year of post-occupancy monitoring data are used to evaluate this method and to investigate the performance of a large-diameter EAHX with up to 16,000 m3/h design airflow rate. Considering an adaptive standard for thermal comfort, peak EAHX cooling capacity of 28 kW (330 kWh/day, with just 50 kWh/day of fan electricity consumption) and office room load extraction of up to 22 kW (49 W/m2) provided evidence in support of standalone use of EAHX for room cooling. A fair fit between actual EAHX thermal performance and results obtained with the graph-based design method support the use of this method for large-diameter EAHX design.

16 June 2022 in arXiv
Verified
Preprint
Open access
PDF file
RDRogério Duarte
Rogério Duarte
ÂNÂngela Lacerda Nobre
Ângela Lacerda Nobre
FPFernando. Carlos Pimentel
Fernando. Carlos Pimentel
Marc M. JacquinetMarc M. Jacquinet
Marc M. Jacquinet
Accreditation bodies call for curriculum development processes open to all stakeholders, reflecting viewpoints of students, industry, university faculty and society. However, communication difficulties between faculty and non-faculty groups leave unexplored an immense collaboration potential. Using classification of learning objectives, natural language processing, and data visualization, this paper presents a method to deliver program plan representations that are universal, self-explanatory, and empowering. A simple example shows how the method contributes to representative program planning experiences and a case study is used to confirm the method's accuracy and utility.

26 February 2021 in HAL
Verified
Preprint
Open access
PDF file
RDRogério Duarte
Rogério Duarte
ÂLÂngela Lacerda-Nobre
Ângela Lacerda-Nobre
FPFernando. Carlos Pimentel
Fernando. Carlos Pimentel
Marc M. JacquinetMarc M. Jacquinet
Marc M. Jacquinet
MDMarc Dcsg
Marc Dcsg
Accreditation bodies call for curriculum development processes open to all stakeholders, reflecting viewpoints of students, industry, university faculty and society. However, communication difficulties between faculty and non-faculty groups leave unexplored an immense collaboration potential. Using classification of learning objectives, natural language processing, and data visualization, this paper presents a method to deliver program plan representations that are universal, self-explanatory, and empowering. A simple example shows how the method contributes to representative program planning experiences and a case study is used to confirm the method's accuracy and utility.

15 December 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
RDRogério Duarte
Rogério Duarte
ARA. Moret Rodrigues
A. Moret Rodrigues
FPFernando. Carlos Pimentel
Fernando. Carlos Pimentel
Maria da Glória GomesMaria da Glória Gomes
Maria da Glória Gomes
In this paper, we use a path model to study natural ventilation in classrooms and research the link between air change rate, occupancy, and both outdoor and indoor physical variables. In general, the path model is derived from the building physics and occupant behavioral considerations via structural equation modeling (SEM), and allows for the use of continuous observable and unobservable factors. The latter are often employed in behavioral and social sciences to represent personal and group attributes. The path model is validated with data gathered during two consecutive academic years from four classrooms of a Portuguese school. The results confirm indoor and outdoor air temperature as major drivers of classroom ventilation, with standardized total path coefficients of approximately 0.55. Solar energy, precipitation, and occupancy are also significant drivers of classroom ventilation, with standardized total path coefficients of 0.24, −0.18, and 0.17, respectively. These results contribute to our understanding of the relative importance of occupancy as well as to identifying the most relevant environmental determinants of natural classroom ventilation. In spite of the statistical significance of the path model as a whole and its detailed causal relationships (direct, indirect, and feedback), only 58% of classroom ventilation variance is explained by the selected input variables. Because naturally ventilated classrooms depend significantly on occupants’ interactions with the built environment, i.e., opening/closing windows and blinds, extending path modeling to include additional personal and context-related drivers of occupants’ behavior would allow for further insights into the complex multi-domain topic of natural classroom ventilation.