Hayaru Shouno

Dr. Hayaru Shouno

orcid

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 March 2025 in IEEE Access
Verified
Journal Article
Open access
THTahir Hussain
Tahir Hussain
HSHayaru Shouno
Hayaru Shouno
AHAbid Hussain
Abid Hussain
DHDostdar Hussain
Dostdar Hussain
MIMuhammad Ismail
Muhammad Ismail
SAShabnur Anonna Akhy
Shabnur Anonna Akhy
The rapid advancement of medical imaging technologies requires the development of advanced, automated, and interpretable diagnostic tools for clinical decision-making. Although convolutional neural networks (CNNs) have shown significant promise in medical image analysis, they have limitations in capturing the global context and lack interpretability, thereby hindering their clinical adoption. This study presents EFFResNet-ViT, a novel hybrid deep learning (DL) model designed to address these challenges by combining EfficientNet-B0 and ResNet-50 CNN backbones with a vision transformer (ViT) module. The proposed architecture employs a feature fusion strategy to integrate the local feature extraction strengths of CNNs with the global dependency modeling capabilities of transformers. The extracted features are further refined through a post-transformer CNN and a global average pooling layer to enhance the classification performance. To improve interpretability, EFFResNet-ViT incorporates Grad-CAM visualization techniques to highlight regions contributing to classification decisions and employs t-distributed stochastic neighbor embedding for feature space analysis, providing insights into class separability. The proposed model was evaluated on two benchmark datasets: brain tumor (BT) CE-MRI for brain tumor classification and a retinal image dataset for ophthalmological diagnosis. EFFResNet-ViT achieved state-of-the-art performance, with accuracies of 99.31% and 92.54% on the BT CE-MRI and retinal datasets, respectively. Comparative analyses demonstrate the superior classification performance and interpretability of EFFResNet-ViT over existingViT and CNN-based hybrid models. The explainable design of EFFResNet-ViT addresses the critical need for transparency in artificial intelligence-driven medical diagnostics, facilitating its potential integration into clinical workflows to improve decision-making and patient outcomes.

1 March 2025 in Knowledge-Based Systems
Verified
Journal Article
Open access
THTahir Hussain
Tahir Hussain
HSHayaru Shouno
Hayaru Shouno
Mazin Abed MohammedMazin Abed Mohammed
Mazin Abed Mohammed
HMHaydar Abdulameer Marhoon
Haydar Abdulameer Marhoon
Taukir AlamTaukir Alam
Taukir Alam

5 March 2024 in IEEE Access
Verified
Journal Article
Open access
THTahir Hussain
Tahir Hussain
HSHayaru Shouno
Hayaru Shouno
Precise segmentation is vital for successful diagnosis and treatment planning. Medical image segmentation has demonstrated remarkable advances with the introduction of deep convolutional neural networks, particularly encoder-decoder networks such as U-Net. Despite their excellent performances, these methods have some limitations. First, the structure is limited in its ability to combine information because feature maps to extract valid information from the final encoding stage are incompatible at the encoding and decoding levels. Second, the approach ignores significant semantic details and does not consider different types of small-scale contextual information when segmenting medical images. Lastly, most methods employing 3D architectures to process input medical images increase the computational complexity of the model without significantly improving the accuracy. To resolve these issues, we propose a segmentation network called Multi-Attention Gated Residual U-Net (MAGRes-UNet). This network incorporates four multi-attention gate (MAG) modules and residual blocks into a standard U-Net structure. The MAG module integrates the information from all encoding stages and focuses on small-scale tumors while disambiguating irrelevant and noisy feature responses, thereby promoting meaningful contextual information. The residual blocks simplify the network training and mitigate the problem of vanishing gradients. This improves the ability of the network to effectively learn intricate features and deep representations. Moreover, our network employs the Mish and ReLU activation functions (AFs), which utilize AdamW and Adam optimization strategies to achieve enhanced segmentation performance. The proposed MAGRes-UNet method was compared with the U-Net, Multi-Attention Gated-UNet (MAG-UNet), and Residual-UNet (ResUNet) models. In addition, a statistical T-test was performed to assess the difference in model significance between the approaches. The analysis revealed that MAGRes-UNet employing Mish and AdamW provides significant performance improvement over the ReLU AF and Adam optimizer on two benchmark datasets: Multi-Class BT T1-weighted Contrast-Enhanced Magnetic Resonance Imaging (T1-CE-MRI) and skin lesions HAM10000 (Human Against Machine with 10,000 training images). MAGRes-UNet using Mish and AdamW provides competitive performance over the representative medical image segmentation methods.

30 November 2023 in Information
Verified
Journal Article
Open access
PDF file
THTahir Hussain
Tahir Hussain
HSHayaru Shouno
Hayaru Shouno
Brain tumors (BT) present a considerable global health concern because of their high mortality rates across diverse age groups. A delay in diagnosing BT can lead to death. Therefore, a timely and accurate diagnosis through magnetic resonance imaging (MRI) is crucial. A radiologist makes the final decision to identify the tumor through MRI. However, manual assessments are flawed, time-consuming, and rely on experienced radiologists or neurologists to identify and diagnose a BT. Computer-aided classification models often lack performance and explainability for clinical translation, particularly in neuroscience research, resulting in physicians perceiving the model results as inadequate due to the black box model. Explainable deep learning (XDL) can advance neuroscientific research and healthcare tasks. To enhance the explainability of deep learning (DL) and provide diagnostic support, we propose a new classification and localization model, combining existing methods to enhance the explainability of DL and provide diagnostic support. We adopt a pre-trained visual geometry group (pre-trained-VGG-19), scratch-VGG-19, and EfficientNet model that runs a modified form of the class activation mapping (CAM), gradient-weighted class activation mapping (Grad-CAM) and Grad-CAM++ algorithms. These algorithms, introduced into a convolutional neural network (CNN), uncover a crucial part of the classification and can provide an explanatory interface for diagnosing BT. The experimental results demonstrate that the pre-trained-VGG-19 with Grad-CAM provides better classification and visualization results than the scratch-VGG-19, EfficientNet, and cutting-edge DL techniques regarding visual and quantitative evaluations with increased accuracy. The proposed approach may contribute to reducing the diagnostic uncertainty and validating BT classification.

24 August 2021 in IEEE Transactions on Circuits and Systems for Video Technology
Verified
Journal Article
Closed access
SSSatoshi Suzuki
Satoshi Suzuki
STShoichiro Takeda
Shoichiro Takeda
MTMotohiro Takagi
Motohiro Takagi
RTRyuichi Tanida
Ryuichi Tanida
HKHideaki Kimata
Hideaki Kimata
HSHayaru Shouno
Hayaru Shouno
Collaborative Intelligence is a new paradigm that splits a deep neural network (DNN) into an edge and cloud for deploying a DNN-based image recognition application. In this paradigm, deep features, which are the outputs of the edge DNN, are compressed and transmitted to the cloud DNN. Because the deep features have a number of responses that are similar to each other, for efficient compression, previous methods spatially arrange and compress the deep features as an image to utilize the similarity as a spatial correlation. However, if the deep features are arranged in not only spatial but also temporal directions like those in a video, it may be possible to compress them more efficiently by increasing a temporal correlation. To explore this possibility, we propose a “spatio-temporal arrangement”. This method spatially arranges the deep features as images and temporally arranges them as a video with a novel ordering search algorithm. Our method effectively increases the spatial and temporal correlations hidden in the deep features and achieves high compression efficiency compared with the previous methods. Experimental results demonstrate the compression efficiency of our method is better than that of the previous methods (1.50% to 4.98% on BD-Rate evaluation in a lossy setting). Our analysis shows that our method effectively increases the correlation when the input is an image with rich edges and textures.

31 January 2020 in Science and Technology of Advanced Materials
Verified
Journal Article
Open access
HSHiroshi Shinotsuka
Hiroshi Shinotsuka
KNKenji Nagata
Kenji Nagata
HYHideki Yoshikawa
Hideki Yoshikawa
YMYoh-ichi Mototake
Yoh-ichi Mototake
HSHayaru Shouno
Hayaru Shouno
MOMasato Okada
Masato Okada
We develop an automatic peak fitting algorithm using the Bayesian information criterion (BIC) fitting method with confidence-interval estimation in spectral decomposition. First, spectral decomposition is carried out by adopting the Bayesian exchange Monte Carlo method for various artificial spectral data, and the confidence interval of fitting parameters is evaluated. From the results, an approximated model formula that expresses the confidence interval of parameters and the relationship between the peak-to-peak distance and the signal-to-noise ratio is derived. Next, for real spectral data, we compare the confidence interval of each peak parameter obtained using the Bayesian exchange Monte Carlo method with the confidence interval obtained from the BIC-fitting with the model selection function and the proposed approximated formula. We thus confirm that the parameter confidence intervals obtained using the two methods agree well. It is therefore possible to not only simply estimate the appropriate number of peaks by BIC-fitting but also obtain the confidence interval of fitting parameters. Graphical abstract